Evaluation of Amplicor PCR for direct detection of Mycobacterium tuberculosis from sputum specimens
Open accessThe DOI matches its Crossref record.
Abstract
We evaluated the Amplicor PCR assay (Roche Molecular Systems, Branchburg, N.J.) for direct detection of Mycobacterium tuberculosis in sputum. A total of 532 specimens from 270 patients were decontaminated and stored at 4 or -75 degrees C until assayed by PCR. This assay used three-step sample preparation, biotinylated primer pairs, AmpErase, and a microtiter format for amplicon capture and detection. Amplicor PCR results were compared with clinical history, culture from a Lowenstein-Jensen slant, and results from the BACTEC TB-460 system. Eighty-seven cultures from 15 patients grew M. tuberculosis; of these, 83 (95%) were positive with the Amplicor PCR test. The false negatives were most likely due to sample variation and inhibitors. Of the 445 specimens from which M. tuberculosis was not isolated, 428 (96%) were negative with the Amplicor PCR test. Of the 17 M. tuberculosis culture-negative, Amplicor-positive specimens, 15 were reclassified as true positives because previous cultures grew M. tuberculosis. Of the 445 specimens which did not grow M. tuberculosis, Mycobacterium spp. other than M. tuberculosis were isolated from 150 specimens. Three of these 150 specimens were Amplicor positive; two were from a patient with a history of tuberculosis, and one specimen gave a false-positive result. We do not feel that this represents cross-reactivity, because repeated Amplicor testing of the isolate gave negative results. The microtiter plate has 96 wells. Allowing for six controls, 90 decontaminated specimens can be tested by one technologist in 7.5 h. This PCR assay took 7.5 h to complete and is a sensitive and specific, rapid method for the direct detection of M. tuberculosis from sputum.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A systematic review of rapid diagnostic tests for the detection of tuberculosis infection
Dinnes, J., Deeks, J., Kunst, H., Gibson, A., Cummins, E., Waugh, N., Drobniewski, F., & Lalvani, A. (2007) · Health Technology Assessment · doi:10.3310/hta11030 · Cited by 666
Iwamoto, T., Sonobe, T., & Hayashi, K. (2003) · Journal of Clinical Microbiology · doi:10.1128/jcm.41.6.2616-2622.2003 · Cited by 612
Molecular diagnostics of infectious diseases
Tang, Y.-W., Procop, G. W., & Persing, D. H. (1997) · Clinical Chemistry · doi:10.1093/clinchem/43.11.2021 · Cited by 305
Ling, D. I., Flores, L. L., Riley, L. W., & Pai, M. (2008) · PLoS ONE · doi:10.1371/journal.pone.0001536 · Cited by 222
“A total of 37 articles were further excluded from data extraction, and 105 articles were included in our metaanalysis [21–125].”
BackgroundCross-Priming Amplification for Rapid Detection of Mycobacterium tuberculosis in Sputum Specimens
Fang, R., Li, X., Hu, L., You, Q., Li, J., Wu, J., Xu, P., Zhong, H., Luo, Y., Mei, J., et al. (2009) · Journal of Clinical Microbiology · doi:10.1128/jcm.01528-08 · Cited by 167
“Several genotypic assays, mostly based on nucleic acid amplification tests, have been developed for rapid TB diagnosis, including the GenProbe amplified Mycobacterium tuberculosis direct test, Roche Amplicor MTB test, Cobas Amplicor test, Abbott LCx test, and the BD-ProbeTec (strand displacement amplification) test (1…”
Method
Metadata
- Authors
- Beavis, K. G., Lichty, M. B., Jungkind, D. L., & Giger, O.
- Venue
- Journal of Clinical Microbiology
- Publisher
- American Society for Microbiology
- Published
- 1995-10
- Volume
- 33
- Issue
- 10
- Pages
- 2582-2586
- ISSN
- 0095-1137 (ISSN-L)
- 1098-660X
- OpenAlex
- W2134488518
- Cited by
- 84
- References
- 0
- FWCI
- 10.02
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluation of Amplicor PCR for direct detection of Mycobacterium tuberculosis from sputum specimens. https://app.cochat.ai/papers/10.1128/jcm.33.10.2582-2586.1995
- The paper
- Beavis, K. G., Lichty, M. B., Jungkind, D. L., & Giger, O. (1995). Evaluation of Amplicor PCR for direct detection of Mycobacterium tuberculosis from sputum specimens. Journal of Clinical Microbiology. https://doi.org/10.1128/jcm.33.10.2582-2586.1995
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.