CoChat

Comparison of visual and spectrophotometric methods of MIC endpoint determinations by using broth microdilution methods to test five antifungal agents, including the new triazole D0870

Open access
Pfaller, M A, Messer, S A, Coffmann, S · 1995 · Journal of Clinical Microbiology
Cited by 109

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

A study to compare three different methods for reading MIC endpoints tested by the broth microdilution modification of the National Committee for Clinical Laboratory Standards (Villanova, Pa.) reference method was conducted. MICs of amphotericin B, flucytosine, fluconazole, itraconazole, and a new triazole, D0870, were determined for five reference yeast strains and 100 clinical isolates of Candida spp. MICs were read visually according to National Committee for Clinical Laboratory Standards guidelines from microdilution trays that had been (VS) and had not been (V) shaken. MICs were also determined spectrophotometrically (SP) at 492 nm. SP endpoints were determined as the concentrations resulting in a > or = 50% inhibition of growth (flucytosine and azoles) and a > or = 90% inhibition of growth (amphotericin B) relative to control growth. The five reference strains were tested nine times each against all five antifungal agents, and the MIC results for each reading method were compared with a 3-log2 dilution reference range determined by the macrodilution (M27-P) method. Overall, 84 to 100% of the MICs determined by V, 93 to 100% of those determined by VS, and 89 to 100% of those determined by SP fell within the 3-log2 dilution reference range for each reference strain and antifungal agent. Reproducibility was 99% for V and SP and 98% for VS. Agreement among the three methods of reading ranged from 97 to 99%. Excellent agreement among reading methods was also observed for all antifungal agents when tested against 100 clinical isolates. Agreement between the standard V method (no agitation) and VS ranged from 99 to 100%, and that between V and SP ranged from 89 to 99%. The VS and SP reading methods provided more definitive endpoints than the V method, which does not involve shaking.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1128/jcm.33.5.1094-1097.1995

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 109

Metadata

Authors
Pfaller, M. A., Messer, S. A., & Coffmann, S.
Venue
Journal of Clinical Microbiology
Published
1995-05
Volume
33
Issue
5
Pages
1094-1097
ISSN
  • 0095-1137 (ISSN-L)
  • 1098-660X
OpenAlex
W2140675445
Cited by
109
References
2
FWCI
9.10
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparison of visual and spectrophotometric methods of MIC endpoint determinations by using broth microdilution methods to test five antifungal agents, including the new triazole D0870. https://app.cochat.ai/papers/10.1128/jcm.33.5.1094-1097.1995
The paper
Pfaller, M. A., Messer, S. A., & Coffmann, S. (1995). Comparison of visual and spectrophotometric methods of MIC endpoint determinations by using broth microdilution methods to test five antifungal agents, including the new triazole D0870. Journal of Clinical Microbiology. https://doi.org/10.1128/jcm.33.5.1094-1097.1995

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.