High-Throughput Real-Time Reverse Transcription-PCR Quantitation of Hepatitis C Virus RNA
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
We describe a rapid and reproducible method for assessment of the hepatitis C virus (HCV) load in serum samples. The method combines Taqman technology (Roche) and the ABI Prism 7700 (Perkin Elmer) real-time sequence detection system. We have optimized a single-tube reverse transcription-PCR (RT-PCR) that contains a dual-labeled fluorogenic probe to quantify the 5′ noncoding region (5′ NCR) of HCV. The probe contains a fluorescent reporter at the 5′ end and a fluorescent quencher at the 3′ end. The use of such a probe combined with the 5′-3′ nuclease activity of Taq polymerase allows direct quantitation of the PCR product by the detection of a fluorescent reporter released in the course of the exponential phase of the PCR. For accurate quantitation of the number of copies of HCV in samples containing unknown quantities, we have used serial dilutions of a synthetic 5′ NCR RNA standard of HCV that was previously quantified with an isotopic tracer. The method has a 5-log dynamic range (10 3 to 10 7 ). The coefficient of regression of the standard curve was, on average, 0.98. The intra-assay and the interassay coefficients of variation of the threshold cycle were 1% and 6.2%, respectively. Seventy-nine RNA samples from the sera of infected patients were quantified by this method. Comparison of the results with those obtained by other quantitation methods (the Quantiplex 2.0 branched-DNA assay and the Superquant assay from the National Genetics Institute) revealed a significant correlation with all of the results. The mean values were also statistically comparable. In conclusion, the high sensitivity, simplicity, and reproducibility of the real-time HCV RNA quantitation which allows the screening of large numbers of samples, combined with its wide dynamic range, make this method especially suitable for monitoring of the viral load during therapy and tailoring of treatment schedules.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A long-term study of hepatitis C virus replication in non-A, non-B hepatitis.
Farci, P., Alter, H. J., Wong, D., Miller, R. H., Shih, J. W., Jett, B., & Purcell, R. H. (1991) · New England Journal of Medicine · doi:10.1056/nejm199107113250205 · Cited by 571 · cited 2×
“Mild.............................................................................................. 8 ( 10 )”
Method
Cited by
Bustin, S. (2000) · Journal of Molecular Endocrinology · doi:10.1677/jme.0.0250169 · Cited by 3,872
An Overview of Real-Time Quantitative PCR: Applications to Quantify Cytokine Gene Expression
Giulietti, A., Overbergh, L., Valckx, D., Decallonne, B., Bouillon, R., & Mathieu, C. (2001) · Methods · doi:10.1006/meth.2001.1261 · Cited by 1,411
Mackay, I. M. (2002) · Nucleic Acids Research · doi:10.1093/nar/30.6.1292 · Cited by 1,318
Real-Time PCR in Clinical Microbiology: Applications for Routine Laboratory Testing
Espy, M. J., Uhl, J. R., Sloan, L. M., Buckwalter, S. P., Jones, M. F., Vetter, E. A., Yao, J. D. C., Wengenack, N. L., Rosenblatt, J. E., Cockerill, F. R., et al. (2006) · Clinical Microbiology Reviews · doi:10.1128/cmr.19.1.165-256.2006 · Cited by 1,318
Lanciotti, R. S., Kerst, A. J., Nasci, R. S., Godsey, M. S., Mitchell, C. J., Savage, H. M., Komar, N., Panella, N. A., Allen, B. C., Volpe, K. E., et al. (2000) · Journal of Clinical Microbiology · doi:10.1128/jcm.38.11.4066-4071.2000 · Cited by 1,087
Metadata
- Authors
- Martell, M., Gómez, J., Esteban, J. I., Sauleda, S., Quer, J., Cabot, B., Esteban, R., & Guardia, J.
- Venue
- Journal of Clinical Microbiology
- Publisher
- American Society for Microbiology
- Published
- 1999-02
- Volume
- 37
- Issue
- 2
- Pages
- 327-332
- ISSN
- 0095-1137 (ISSN-L)
- 1098-660X
- OpenAlex
- W1640867508
- Cited by
- 233
- References
- 1
- FWCI
- 14.79
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.