The DOI matches its Crossref record.
Development and Evaluation of a Quantitative, Touch-Down, Real-Time PCR Assay for Diagnosing Pneumocystis carinii Pneumonia
Open accessAbstract
A rapid (time to completion, <4 h, including DNA extraction) and quantitative touch-down (QTD) real-time diagnostic Pneumocystis carinii PCR assay with an associated internal control was developed, using fluorescence resonance energy transfer (FRET) probes for detection. The touch-down procedure significantly increased the sensitivity of the assay compared to a non-touch-down procedure. Tenfold serial dilutions of a cloned target were used as standards for quantification. P. carinii DNA has been detected in respiratory specimens from patients with P. carinii pneumonia (PCP) and from patients without clinical evidence of PCP. The latter probably represents colonization or subclinical infection. It is logical to hypothesize that quantification might prove helpful in distinguishing between infected and colonized patients: the latter group would have lower copy numbers than PCP patients. A blinded retrospective study of 98 respiratory samples (49 lower respiratory tract specimens and 49 oral washes), from 51 patients with 24 episodes of PCP and 34 episodes of other respiratory disease, was conducted. PCR-positive samples from colonized patients contained a lower concentration of P. carinii DNA than samples from PCP patients: lower respiratory tract samples from PCP and non-PCP patients contained a median of 938 (range, 2.4 to 1,040,000) and 2.6 (range, 0.3 to 248) ( P < 0.0004) copies per tube, respectively. Oral washes from PCP and non-PCP patients contained a median of 49 (range, 2.1 to 2,595) and 6.5 (range, 2.2 to 10) ( P < 0.03) copies per tube, respectively. These data suggest that this QTD PCR assay can be used to determine if P. carinii is present in respiratory samples and to distinguish between colonization and infection.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Real-Time PCR in Clinical Microbiology: Applications for Routine Laboratory Testing
Espy, M. J., Uhl, J. R., Sloan, L. M., Buckwalter, S. P., Jones, M. F., Vetter, E. A., Yao, J. D. C., Wengenack, N. L., Rosenblatt, J. E., Cockerill, F. R., et al. (2006) · Clinical Microbiology Reviews · doi:10.1128/cmr.19.1.165-256.2006 · Cited by 1,318
Cooley, L., Dendle, C., Wolf, J., Teh, B. W., Chen, S. C., Boutlis, C., & Thursky, K. A. (2014) · Internal Medicine Journal · doi:10.1111/imj.12599 · Cited by 228
Pneumocystis Pneumonia: Current Concepts in Pathogenesis, Diagnosis, and Treatment
Krajicek, B. J., Thomas, C. F., & Limper, A. H. (2009) · Clinics in Chest Medicine · doi:10.1016/j.ccm.2009.02.005 · Cited by 73
Harrison, N., Mitterbauer, M., Tobudic, S., Kalhs, P., Rabitsch, W., Greinix, H., Burgmann, H., Willinger, B., Presterl, E., & Forstner, C. (2015) · BMC Infectious Diseases · doi:10.1186/s12879-015-1329-6 · Cited by 73
Metadata
- Authors
- Larsen, H. H., Masur, H., Kovacs, J. A., Gill, V. J., Silcott, V. A., Kogulan, P., Maenza, J., Smith, M., Lucey, D. R., & Fischer, S. H.
- Venue
- Journal of Clinical Microbiology
- Publisher
- American Society for Microbiology
- Published
- 2002-02
- Volume
- 40
- Issue
- 2
- Pages
- 490-494
- ISSN
- 0095-1137 (ISSN-L)
- 1098-660X
- OpenAlex
- W2136616064
- Cited by
- 172
- References
- 0
- FWCI
- 8.56
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.