Blood Culture Contamination: Persisting Problems and Partial Progress
Open accessThe DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
Although it has been widely appreciated for many years among physicians and microbiologists that blood cultures are among the most important laboratory tests performed in the diagnosis of serious infections (35), it has become equally apparent in more recent years that contaminated blood cultures are common (25, 42), enormously costly (3, 29), and frequently confusing for clinicians (1, 12, 14, 26). Clinical studies of bloodstream infections over 3 decades have provided guidelines for differentiating true pathogens from contaminants or organisms of unknown significance (14, 18, 41, 42); however, a true “gold standard” for differentiating pathogens from contaminants does not exist (4, 25). Moreover, the most common blood culture contaminants, coagulase-negative staphylococci (CoNS), which were almost always such several decades ago (18, 41), now are pathogens more frequently (19, 25, 26, 42), and judging the clinical significance of this group of microorganisms in blood has proven to be especially problematic (1, 11, 22, 24, 26, 42; S. J. Peacock, I. C. Bowler, and D. W. Crook., Letter, Lancet 346:191-192, 1995). This review focuses on how pathogen-contaminant decisions are made, the phenomenon of increasing contamination of blood cultures, potential methods for addressing high contamination rates, and practical laboratory approaches to the workup of likely contaminants.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Weinstein, M. P., Towns, M. L., Quartey, S. M., Mirrett, S., Reimer, L. G., Parmigiani, G., & Barth Reller, L. (1997) · Clinical Infectious Diseases · doi:10.1093/clind/24.4.584 · Cited by 1,228
Self-citationWeinstein, M. P., Reller, L. B., Murphy, J. R., & Lichtenstein, K. A. (1983) · Clinical Infectious Diseases · doi:10.1093/clinids/5.1.35 · Cited by 751
Self-citationContaminant blood cultures and resource utilization. The true consequences of false-positive results
Bates, D. W. (1991) · JAMA · doi:10.1001/jama.265.3.365 · Cited by 570
Coagulase-Negative Staphylococci: Pathogens Associated with Medical Progress
Rupp, M. E., & Archer, G. L. (1994) · Clinical Infectious Diseases · doi:10.1093/clinids/19.2.231 · Cited by 487
Update on detection of bacteremia and fungemia
Reimer, L. G., Wilson, M. L., & Weinstein, M. P. (1997) · Clinical Microbiology Reviews · doi:10.1128/cmr.10.3.444 · Cited by 482
Self-citationCoagulase-Negative Staphylococcal Bacteremia: Mortality and Hospital Stay
Martin, M. A., Pfaller, M. A., & Wenzel, R. P. (1989) · Annals of Internal Medicine · doi:10.7326/0003-4819-110-1-9 · Cited by 333
Weinstein, M. P. (1996) · Clinical Infectious Diseases · doi:10.1093/clinids/23.1.40 · Cited by 324
Self-citationSouvenir, D., Anderson, D. E., Palpant, S., Mroch, H., Askin, S., Anderson, J., Claridge, J., Eiland, J., Malone, C., Garrison, M. W., et al. (1998) · Journal of Clinical Microbiology · doi:10.1128/jcm.36.7.1923-1926.1998 · Cited by 289
MacGregor, R. R. (1972) · Archives of Internal Medicine · doi:10.1001/archinte.130.1.84 · Cited by 232
Blood cultures: principles and techniques.
Washington, J. A. (1975) · PubMed · Cited by 204
Diagnostic Decision: Blood Cultures
ARONSON, M. D., & BOR, D. H. (1987) · Annals of Internal Medicine · doi:10.7326/0003-4819-106-2-246 · Cited by 204
DesJardin, J. A., Falagas, M. E., Ruthazer, R., Griffith, J., Wawrose, D., Schenkein, D., Miller, K., & Snydman, D. R. (1999) · Annals of Internal Medicine · doi:10.7326/0003-4819-131-9-199911020-00002 · Cited by 177
Mimoz, O., Karim, A., Mercat, A., Cosseron, M., Falissard, B., Parker, F., Richard, C., Samii, K., & Nordmann, P. (1999) · Annals of Internal Medicine · doi:10.7326/0003-4819-131-11-199912070-00006 · Cited by 177
Richter, S. S., Beekmann, S. E., Croco, J. L., Diekema, D. J., Koontz, F. P., Pfaller, M. A., & Doern, G. V. (2002) · Journal of Clinical Microbiology · doi:10.1128/jcm.40.7.2437-2444.2002 · Cited by 160
Weinstein, M. P., Mirrett, S., Reimer, L. G., Wilson, M. L., Smith-Elekes, S., Chuard, C. R., Joho, K. L., & Reller, L. B. (1995) · Journal of Clinical Microbiology · doi:10.1128/jcm.33.4.978-981.1995 · Cited by 143
Self-citationLittle, J. R., Murray, P. R., Traynor, P., & Spitznagel, E. (1999) · The American Journal of Medicine · doi:10.1016/s0002-9343(99)00197-7 · Cited by 122
Mirrett, S., Weinstein, M. P., Reimer, L. G., Wilson, M. L., & Reller, L. B. (2001) · Journal of Clinical Microbiology · doi:10.1128/jcm.39.9.3279-3281.2001 · Cited by 119
Self-citationWeinstein, M. P., Mirrett, S., Van Pelt, L., McKinnon, M., Zimmer, B. L., Kloos, W., & Reller, L. B. (1998) · Journal of Clinical Microbiology · doi:10.1128/jcm.36.7.2089-2092.1998 · Cited by 75
Self-citationContamination of Catheter-Drawn Blood Cultures
Everts, R. J., Vinson, E. N., Adholla, P. O., & Reller, L. B. (2001) · Journal of Clinical Microbiology · doi:10.1128/jcm.39.9.3393-3394.2001 · Cited by 75
Kim, S.-D., McDonald, L. C., Jarvis, W. R., McAllister, S. K., Jerris, R. C., Carson, L. A., & Miller, J. M. (2000) · Infection Control and Hospital Epidemiology · doi:10.1086/501747 · Cited by 68
Controlled evaluation of BACTEC Plus 26 and Roche Septi-Chek aerobic blood culture bottles
Weinstein, M. P., Mirrett, S., Wilson, M. L., Harrell, L. J., Stratton, C. W., & Reller, L. B. (1991) · Journal of Clinical Microbiology · doi:10.1128/jcm.29.5.879-882.1991 · Cited by 51
Self-citationBlood Culture Phlebotomy: Switching Needles Does Not Prevent Contamination
Krumholz, H. M., Cummings, S., & York, M. (1990) · Annals of Internal Medicine · doi:10.7326/0003-4819-113-4-290 · Cited by 41
Lack of effect of changing needles on contamination of blood cultures
Isaacman, D. J., & KARASIC, R. B. (1990) · The Pediatric Infectious Disease Journal · doi:10.1097/00006454-199004000-00010 · Cited by 38
Cited by
Updated Review of Blood Culture Contamination
Hall, K. K., & Lyman, J. A. (2006) · Clinical Microbiology Reviews · doi:10.1128/cmr.00062-05 · Cited by 875
New developments in the diagnosis of bloodstream infections
Peters, R. P., van Agtmael, M. A., Danner, S. A., Savelkoul, P. H., & Vandenbroucke-Grauls, C. M. (2004) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(04)01205-8 · Cited by 398
Doern, G. V., Carroll, K. C., Diekema, D. J., Garey, K. W., Rupp, M. E., Weinstein, M. P., & Sexton, D. J. (2019) · Clinical Microbiology Reviews · doi:10.1128/cmr.00009-19 · Cited by 313
Self-citationSeptimus, E. J. (2018) · Medical Clinics of North America · doi:10.1016/j.mcna.2018.04.005 · Cited by 239
Bekeris, L. G., Tworek, J. A., Walsh, M. K., & Valenstein, P. N. (2005) · Archives of Pathology & Laboratory Medicine · doi:10.5858/2005-129-1222-tibcca · Cited by 232
Metadata
- Authors
- Weinstein, M. P.
- Venue
- Journal of Clinical Microbiology
- Publisher
- American Society for Microbiology
- Published
- 2003-06
- Volume
- 41
- Issue
- 6
- Pages
- 2275-2278
- ISSN
- 0095-1137 (ISSN-L)
- 1098-660X
- OpenAlex
- W1973287182
- Cited by
- 382
- References
- 23
- FWCI
- 4.69
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.