Real-Time Nucleic Acid Sequence-Based Amplification Using Molecular Beacons for Detection of Enterovirus RNA in Clinical Specimens
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Real-time nucleic acid sequence-based amplification (NASBA) using molecular beacon technology (NASBA-beacon) was compared to standard NASBA with postamplification hybridization using electrochemiluminescently labeled probes (NASBA-ECL) for detection of enteroviruses (EV) in 133 cerebrospinal fluid and 27 stool samples. NASBA-ECL and NASBA-beacon were similar in sensitivity, detecting 55 (100%) and 52 (94.5%) EV-positive samples, respectively. There were no false positives. Both NASBA assays were significantly more sensitive than culture. Real-time NASBA-beacon reagents and equipment rental were more expensive than those for NASBA-ECL; however, time to result was shortened by 1.5 h, hands-on time was reduced by 25 min, and the assay was much simpler for technologists to learn and perform.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lanciotti, R. S., & Kerst, A. J. (2001) · Journal of Clinical Microbiology · doi:10.1128/jcm.39.12.4506-4513.2001 · Cited by 267
ROBINSON, C. C., WILLIS, M., MEAGHER, A., GIESEKER, K. E., ROTBART, H., & GLODÉ, M. P. (2002) · The Pediatric Infectious Disease Journal · doi:10.1097/00006454-200204000-00005 · Cited by 131
Fox, J. D., Han, S., Samuelson, A., Zhang, Y., Neale, M. L., & Westmoreland, D. (2002) · Journal of Clinical Virology · doi:10.1016/s1386-6532(01)00241-4 · Cited by 84 · cited 2×
“Although reverse transcription-PCR (RT-PCR) is the most commonly used test, nucleic acid sequence-based amplification (NASBA) using the Nuclisens Basic Kit has proved of equal or greater sensitivity for detection of enteroviruses (2, 6, 7).”
Method
Cited by
Lee, B. E., & Davies, H. D. (2007) · Current Opinion in Infectious Diseases · doi:10.1097/qco.0b013e3280ad4672 · Cited by 163
Kreutz, J. E., Munson, T., Huynh, T., Shen, F., Du, W., & Ismagilov, R. F. (2011) · Analytical Chemistry · doi:10.1021/ac201658s · Cited by 148
Marlowe, E. M., Novak, S. M., Dunn, J. J., Smith, A., Cumpio, J., Makalintal, E., Barnes, D., & Burchette, R. J. (2008) · Journal of Clinical Virology · doi:10.1016/j.jcv.2008.04.006 · Cited by 40
Molecular diagnostics in cerebrospinal fluid for the diagnosis of central nervous system infections
Olie, S. E., Andersen, C. Ø., van de Beek, D., & Brouwer, M. C. (2024) · Clinical Microbiology Reviews · doi:10.1128/cmr.00021-24 · Cited by 38
“Two studies, including 21 and 13 viral culture-positive patients, found that NASBA was 100% sensitive to enterovirus RNA detection and that NASBA was able to detect more suspected cases than culture (206, 207).”
Metadata
- Authors
- Landry, M. L., Garner, R., & Ferguson, D.
- Venue
- Journal of Clinical Microbiology
- Publisher
- American Society for Microbiology
- Published
- 2005-07
- Volume
- 43
- Issue
- 7
- Pages
- 3136-3139
- ISSN
- 0095-1137 (ISSN-L)
- 1098-660X
- OpenAlex
- W2141224495
- Cited by
- 51
- References
- 3
- FWCI
- 4.03
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Real-Time Nucleic Acid Sequence-Based Amplification Using Molecular Beacons for Detection of Enterovirus RNA in Clinical Specimens. https://app.cochat.ai/papers/10.1128/jcm.43.7.3136-3139.2005
- The paper
- Landry, M. L., Garner, R., & Ferguson, D. (2005). Real-Time Nucleic Acid Sequence-Based Amplification Using Molecular Beacons for Detection of Enterovirus RNA in Clinical Specimens. Journal of Clinical Microbiology. https://doi.org/10.1128/jcm.43.7.3136-3139.2005
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.