Rapid Detection of HIV-1 Proviral DNA for Early Infant Diagnosis Using Recombinase Polymerase Amplification
Open accessThe DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Abstract
Early diagnosis and treatment of human immunodeficiency virus type 1 (HIV-1) infection in infants can greatly reduce mortality rates. However, current infant HIV-1 diagnostics cannot reliably be performed at the point of care, often delaying treatment and compromising its efficacy. Recombinase polymerase amplification (RPA) is a novel technology that is ideal for an HIV-1 diagnostic, as it amplifies target DNA in <20 min at a constant temperature, without the need for complex thermocycling equipment. Here we tested 63 HIV-1-specific primer and probe combinations and identified two RPA assays that target distinct regions of the HIV-1 genome (long terminal repeat [LTR] and pol) and can reliably detect 3 copies of proviral DNA by the use of fluorescence detection and lateral-flow strip detection. These pol and LTR primers amplified 98.6% and 93%, respectively, of the diverse HIV-1 variants tested. This is the first example of an isothermal assay that consistently detects all of the major HIV-1 global subtypes. IMPORTANCE Diagnosis of HIV-1 infection in infants cannot rely on the antibody-based tests used in adults because of the transfer of maternal HIV-1 antibodies from mother to child. Therefore, infant diagnostics rely on detection of the virus itself. However, current infant HIV-1 diagnostic methods require a laboratory setting with complex equipment. Here we describe the initial development of an HIV-1 diagnostic for infants that may be performed at the point of care in rural health clinics. We utilize a method that can amplify and detect HIV-1 DNA at an incubation temperature within the range of 25 to 42°C, eliminating the need for thermocycling equipment. HIV-1 diagnostics are challenging to develop due to the high diversity seen in HIV-1 strains worldwide. Here we show that this method detects the major HIV-1 strains circulating globally.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
DNA Detection Using Recombination Proteins
Piepenburg, O., Williams, C. H., Stemple, D. L., & Armes, N. A. (2006) · PLoS Biology · doi:10.1371/journal.pbio.0040204 · Cited by 2,482
Self-citationTomita, N., Mori, Y., Kanda, H., & Notomi, T. (2008) · Nature Protocols · doi:10.1038/nprot.2008.57 · Cited by 1,867
Mori, Y., Nagamine, K., Tomita, N., & Notomi, T. (2001) · Biochemical and Biophysical Research Communications · doi:10.1006/bbrc.2001.5921 · Cited by 1,711
Early Antiretroviral Therapy and Mortality among HIV-Infected Infants
Violari, A., Cotton, M. F., Gibb, D. M., Babiker, A. G., Steyn, J., Madhi, S. A., Jean-Philippe, P., & McIntyre, J. A. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa0800971 · Cited by 1,418
Newell, M.-L., Coovadia, H., Cortina-Borja, M., Rollins, N., Gaillard, P., & Dabis, F. (2004) · The Lancet · doi:10.1016/s0140-6736(04)17140-7 · Cited by 1,182
Goto, M., Honda, E., Ogura, A., Nomoto, A., & Hanaki, K.-I. (2009) · BioTechniques · doi:10.2144/000113072 · Cited by 1,063
Point-of-care nucleic acid testing for infectious diseases
Niemz, A., Ferguson, T. M., & Boyle, D. S. (2011) · Trends in Biotechnology · doi:10.1016/j.tibtech.2011.01.007 · Cited by 838
Self-citationDuh, E. J., Maury, W. J., Folks, T. M., Fauci, A. S., & Rabson, A. B. (1989) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.86.15.5974 · Cited by 767
Global trends in molecular epidemiology of HIV-1 during 2000–2007
Hemelaar, J., Gouws, E., Ghys, P. D., & Osmanov, S. (2011) · AIDS · doi:10.1097/qad.0b013e328342ff93 · Cited by 692
The Challenge of HIV-1 Subtype Diversity
Taylor, B. S., Sobieszczyk, M. E., McCutchan, F. E., & Hammer, S. M. (2008) · New England Journal of Medicine · doi:10.1056/nejmra0706737 · Cited by 635
Cited by
Recombinase polymerase amplification: Basics, applications and recent advances
Lobato, I. M., & O'Sullivan, C. K. (2018) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2017.10.015 · Cited by 1,146
Recombinase Polymerase Amplification for Diagnostic Applications
Daher, R. K., Stewart, G., Boissinot, M., & Bergeron, M. G. (2016) · Clinical Chemistry · doi:10.1373/clinchem.2015.245829 · Cited by 740
Review: a comprehensive summary of a decade development of the recombinase polymerase amplification
Li, J., Macdonald, J., & von Stetten, F. (2019) · The Analyst · doi:10.1039/c8an01621f · Cited by 648
A SERS-based lateral flow assay biosensor for highly sensitive detection of HIV-1 DNA
Fu, X., Cheng, Z., Yu, J., Choo, P., Chen, L., & Choo, J. (2016) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2015.11.099 · Cited by 377
Spin-enhanced nanodiamond biosensing for ultrasensitive diagnostics
Miller, B. S., Bezinge, L., Gliddon, H. D., Huang, D., Dold, G., Gray, E. R., Heaney, J., Dobson, P. J., Nastouli, E., Morton, J. J. L., et al. (2020) · Nature · doi:10.1038/s41586-020-2917-1 · Cited by 360
Self-powered integrated microfluidic point-of-care low-cost enabling (SIMPLE) chip
Yeh, E.-C., Fu, C.-C., Hu, L., Thakur, R., Feng, J., & Lee, L. P. (2017) · Science Advances · doi:10.1126/sciadv.1501645 · Cited by 347
Equipment-Free Incubation of Recombinase Polymerase Amplification Reactions Using Body Heat
Crannell, Z. A., Rohrman, B., & Richards-Kortum, R. (2014) · PLoS ONE · doi:10.1371/journal.pone.0112146 · Cited by 276
Abd El Wahed, A., El-Deeb, A., El-Tholoth, M., Abd El Kader, H., Ahmed, A., Hassan, S., Hoffmann, B., Haas, B., Shalaby, M. A., Hufert, F. T., et al. (2013) · PLoS ONE · doi:10.1371/journal.pone.0071642 · Cited by 209
“In a recent study, up to nine mismatches within RPA primers and exo-probe did not affect the HIV-1 RPA assay performance [25].”
BackgroundRapid Detection of Mycobacterium tuberculosis by Recombinase Polymerase Amplification
Boyle, D. S., McNerney, R., Teng Low, H., Leader, B. T., Pérez-Osorio, A. C., Meyer, J. C., O'Sullivan, D. M., Brooks, D. G., Piepenburg, O., & Forrest, M. S. (2014) · PLoS ONE · doi:10.1371/journal.pone.0103091 · Cited by 164
“The RPA reactions were incubated at 39uC using a combined heating and fluorescence detection device (Twista, TwistDx, UK) [22].”
MethodSelf-citation
Metadata
- Authors
- Boyle, D. S., Lehman, D. A., Lillis, L., Peterson, D., Singhal, M., Armes, N., Parker, M., Piepenburg, O., & Overbaugh, J.
- Venue
- mBio
- Publisher
- American Society for Microbiology
- Published
- 2013-05
- Volume
- 4
- Issue
- 2
- ISSN
- 2150-7511 (ISSN-L)
- 2161-2129
- OpenAlex
- W2157172171
- Cited by
- 258
- References
- 41
- FWCI
- 10.81
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.