The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Physical mechanisms of the therapeutic effect of ultrasound (a review)
Abstract
Therapeutic ultrasound is an emerging field with many medical applications. High intensity focused ultrasound (HIFU) provides the ability to localize the deposition of acoustic energy within the body, which can cause tissue necrosis and hemostasis. Similarly, shock waves from a lithotripter penetrate the body to comminute kidney stones, and transcutaneous ultrasound enhances the transport of chemotherapy agents. New medical applications have required advances in transducer design and advances in numerical and experimental studies of the interaction of sound with biological tissues and fluids. The primary physical mechanism in HIFU is the conversion of acoustic energy into heat, which is often enhanced by nonlinear acoustic propagation and nonlinear scattering from bubbles. Other mechanical effects from ultrasound appear to stimulate an immune response, and bubble dynamics play an important role in lithotripsy and ultrasound-enhanced drug delivery. A dramatic shift to understand and exploit these nonlinear and mechanical mechanisms has occurred over the last few years. Specific challenges remain, such as treatment protocol planning and real-time treatment monitoring. An improved understanding of the physical mechanisms is essential to meet these challenges and to further advance therapeutic ultrasound.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Vetterling, W. T., Teukolsky, S. A., Press, W. H., & Flannery, B. P. (1988) · Cited by 7,701
Press, W. H., Teukolsky, S. L. A., Flannery, B. P., & Vetterling, W. T. (1990) · Infoscience (Ecole Polytechnique Fédérale de Lausanne) · Cited by 6,980
Analysis of Tissue and Arterial Blood Temperatures in the Resting Human Forearm
Pennes, H. H. (1948) · Journal of Applied Physiology · doi:10.1152/jappl.1948.1.2.93 · Cited by 4,646
Thermal dose determination in cancer therapy
Sapareto, S. A., & Dewey, W. C. (1984) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/0360-3016(84)90379-1 · Cited by 2,498
EXTRACORPOREALLY INDUCED DESTRUCTION OF KIDNEY STONES BY SHOCK WAVES
Chaussy, C., Brendel, W., & Schmiedt, E. (1980) · The Lancet · doi:10.1016/s0140-6736(80)92335-1 · Cited by 1,206
Gauging the likelihood of cavitation from short-pulse, low-duty cycle diagnostic ultrasound
Apfel, R. E., & Holland, C. K. (1991) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(91)90125-g · Cited by 690
MR Imaging-guided Focused Ultrasound Surgery of Fibroadenomas in the Breast: A Feasibility Study
Hynynen, K., Pomeroy, O., Smith, D. N., Huber, P. E., McDannold, N. J., Kettenbach, J., Baum, J., Singer, S., & Jolesz, F. A. (2001) · Radiology · doi:10.1148/radiology.219.1.r01ap02176 · Cited by 634
O'Neil, H. T. (1949) · The Journal of the Acoustical Society of America · doi:10.1121/1.1906542 · Cited by 575
A non-invasive method for focusing ultrasound through the human skull
Clement, G. T., & Hynynen, K. (2002) · Physics in Medicine and Biology · doi:10.1088/0031-9155/47/8/301 · Cited by 510
The threshold for thermally significant cavitation in dog's thigh muscle in vivo
Hynynen, K. (1991) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(91)90123-e · Cited by 430
Cited by
Applications of Acoustics and Cavitation to Noninvasive Therapy and Drug Delivery
Coussios, C. C., & Roy, R. A. (2008) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.40.111406.102116 · Cited by 532
Schroeder, A., Kost, J., & Barenholz, Y. (2009) · Chemistry and Physics of Lipids · doi:10.1016/j.chemphyslip.2009.08.003 · Cited by 485
A Review of Acoustic Impedance Matching Techniques for Piezoelectric Sensors and Transducers
Rathod, V. T. (2020) · Sensors · doi:10.3390/s20144051 · Cited by 328
Histotripsy methods in mechanical disintegration of tissue: Towards clinical applications
Khokhlova, V. A., Fowlkes, J. B., Roberts, W. W., Schade, G. R., Xu, Z., Khokhlova, T. D., Hall, T. L., Maxwell, A. D., Wang, Y.-N., & Cain, C. A. (2015) · International Journal of Hyperthermia · doi:10.3109/02656736.2015.1007538 · Cited by 317
Self-citationActivating Drugs with Sound: Mechanisms Behind Sonodynamic Therapy and the Role of Nanomedicine
Choi, V., Rajora, M. A., & Zheng, G. (2020) · Bioconjugate Chemistry · doi:10.1021/acs.bioconjchem.0c00029 · Cited by 237
Metadata
- Authors
- Bailey, M. R., Khokhlova, V. A., Sapozhnikov, O. A., Kargl, S. G., & Crum, L. A.
- Venue
- Acoustical Physics
- Publisher
- Pleiades Publishing Ltd
- Published
- 2003-07
- Volume
- 49
- Issue
- 4
- Pages
- 369-388
- ISSN
- 1063-7710 (ISSN-L)
- 1562-6865
- OpenAlex
- W1979921670
- Cited by
- 465
- References
- 27
- FWCI
- 5.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Physical mechanisms of the therapeutic effect of ultrasound (a review). https://app.cochat.ai/papers/10.1134/1.1591291
- The paper
- Bailey, M. R., Khokhlova, V. A., Sapozhnikov, O. A., Kargl, S. G., & Crum, L. A. (2003). Physical mechanisms of the therapeutic effect of ultrasound (a review). Acoustical Physics. https://doi.org/10.1134/1.1591291
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.