Accuracy of tympanic and infrared skin thermometers in children
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
BACKGROUND: Rectal measurement is considered a gold standard in many healthcare systems for body temperature measurement in children. Although this method has several disadvantages, an ideal alternative thermometer has not yet been introduced. However tympanic and infrared skin thermometers are potential alternatives. METHODS: A prospective cohort study was performed including 100 children between 0 and 18 years of age admitted to the general paediatric ward of Spaarne Hospital in The Netherlands between January and March 2009. The objectives of this study are to evaluate the accuracy of tympanic and two types of infrared skin thermometers (Beurer and Thermofocus) compared to rectal measurement and furthermore to evaluate the influence of different variables on temperature measurements. RESULTS: Compared to rectal measurement (37.56°C), the mean temperatures of the tympanic (37.29°C), Beurer (36.79°C) and Thermofocus (37.30°C) thermometers differed significantly (p<0.001). Mean and SD of differences between rectal temperature and temperature measured with these alternative devices varied significantly (p<0.001). Sensitivity, specificity, positive and negative predictive values for detecting rectal fever measured with the tympanic, Beurer and Thermofocus thermometers are unacceptable, especially for the Beurer thermometer. This difference in temperature between rectal and the alternative thermometers remained after stratification on gender, age, skin colour and otoscopic abnormalities. CONCLUSIONS: In this study the authors demonstrated that the tympanic, Beurer and Thermofocus thermometers cannot reliably predict rectal temperature. Therefore the authors do not advise replacement of rectal measurement as the gold standard for detecting fever in children by one of these devices. When rectal measurement is not used, the infrared skin thermometers appear to perform less well than tympanic measurements.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Thermometry in paediatric practice
El-Radhi, A. S. (2006) · Archives of Disease in Childhood · doi:10.1136/adc.2005.088831 · Cited by 160
Dodd, S. R., Lancaster, G. A., Craig, J. V., Smyth, R. L., & Williamson, P. R. (2006) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2005.10.004 · Cited by 90
Cited by
Niven, D. J., Gaudet, J. E., Laupland, K. B., Mrklas, K. J., Roberts, D. J., & Stelfox, H. T. (2015) · Annals of Internal Medicine · doi:10.7326/m15-1150 · Cited by 240
Pecoraro, V., Petri, D., Costantino, G., Squizzato, A., Moja, L., Virgili, G., & Lucenteforte, E. (2021) · Internal and Emergency Medicine · doi:10.1007/s11739-020-02556-0 · Cited by 49
“Paes 2010 [54] Cohort Pediatric unit Children 100 Rectal, digital Tympanic, infrared Temporal, infrared”
Khan, S., Saultry, B., Adams, S., Kouzani, A. Z., Decker, K., Digby, R., & Bucknall, T. (2021) · American Journal of Infection Control · doi:10.1016/j.ajic.2020.09.012 · Cited by 49
Hayward, G., Verbakel, J. Y., Ismail, F. A., Edwards, G., Wang, K., Fleming, S., Holtman, G. A., Glogowska, M., Morris, E., Curtis, K., et al. (2020) · British Journal of General Practice · doi:10.3399/bjgp20x708845 · Cited by 26
Metadata
- Authors
- Paes, B. F., Vermeulen, K., Brohet, R. M., van der Ploeg, T., & de Winter, J. P.
- Venue
- Archives of Disease in Childhood
- Publisher
- BMJ
- Published
- 2010-08-24
- Volume
- 95
- Issue
- 12
- Pages
- 974-978
- ISSN
- 0003-9888 (ISSN-L)
- 1468-2044
- OpenAlex
- W2100728334
- Cited by
- 71
- References
- 2
- FWCI
- 3.55
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.