OBJECTIVE: To identify the frequency of medication administration errors and their potential risk factors in units using a computerized prescription order entry program and profiled automated dispensing cabinets. DESIGN: Prospective observational study conducted within two clinical units of the Gastroenterology Department in a 1537-bed tertiary teaching hospital in Madrid (Spain). MEASUREMENTS: Medication errors were measured using the disguised observation technique. Types of medication errors and their potential severity were described. The correlation between potential risk factors and medication errors was studied to identify potential causes. RESULTS: In total, 2314 medication administrations to 73 patients were observed: 509 errors were recorded (22.0%)-68 (13.4%) in preparation and 441 (86.6%) in administration. The most frequent errors were use of wrong administration techniques (especially concerning food intake (13.9%)), wrong reconstitution/dilution (1.7%), omission (1.4%), and wrong infusion speed (1.2%). Errors were classified as no damage (95.7%), no damage but monitoring required (2.3%), and temporary damage (0.4%). Potential clinical severity could not be assessed in 1.6% of cases. The potential risk factors morning shift, evening shift, Anatomical Therapeutic Chemical medication class antacids, prokinetics, antibiotics and immunosuppressants, oral administration, and intravenous administration were associated with a higher risk of administration errors. No association was found with variables related to understaffing or nurse's experience. CONCLUSIONS: Medication administration errors persist in units with automated prescription and dispensing. We identified a need to improve nurses' working procedures and to implement a Clinical Decision Support tool that generates recommendations about scheduling according to dietary restrictions, preparation of medication before parenteral administration, and adequate infusion rates.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Incidence of Adverse Drug Events and Potential Adverse Drug Events: Implications for Prevention
Bates, D. W. (1995) · JAMA · doi:10.1001/jama.1995.03530010043033 · Cited by 2,127
Systems Analysis of Adverse Drug Events
Leape, L. L. (1995) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1995.03530010049034 · Cited by 1,404
Comparison of methods for detecting medication errors in 36 hospitals and skilled-nursing facilities
Flynn, E. A., Barker, K. N., Pepper, G. A., Bates, D. W., & Mikeal, R. L. (2002) · American Journal of Health-System Pharmacy · doi:10.1093/ajhp/59.5.436 · Cited by 449
Cited by
Keers, R. N., Williams, S. D., Cooke, J., & Ashcroft, D. M. (2013) · Drug Safety · doi:10.1007/s40264-013-0090-2 · Cited by 514
Keers, R. N., Williams, S. D., Cooke, J., & Ashcroft, D. M. (2013) · Annals of Pharmacotherapy · doi:10.1345/aph.1r147 · Cited by 354
Automation of in-hospital pharmacy dispensing: a systematic review
Batson, S., Herranz, A., Rohrbach, N., Canobbio, M., Mitchell, S. A., & Bonnabry, P. (2021) · European Journal of Hospital Pharmacy · doi:10.1136/ejhpharm-2019-002081 · Cited by 82
Ahtiainen, H. K., Kallio, M. M., Airaksinen, M., & Holmström, A.-R. (2020) · European Journal of Hospital Pharmacy · doi:10.1136/ejhpharm-2018-001791 · Cited by 78
Jumeau, M., Francois, O., & Bonnabry, P. (2023) · European Journal of Hospital Pharmacy · doi:10.1136/ejhpharm-2021-002849 · Cited by 13
Metadata
- Authors
- Rodriguez-Gonzalez, C. G., Herranz-Alonso, A., Martin-Barbero, M. L., Duran-Garcia, E., Durango-Limarquez, M. I., Hernández-Sampelayo, P., & Sanjurjo-Saez, M.
- Venue
- Journal of the American Medical Informatics Association
- Publisher
- Oxford University Press (OUP)
- Published
- 2012-01
- Volume
- 19
- Issue
- 1
- Pages
- 72-78
- ISSN
- 1067-5027 (ISSN-L)
- 1527-974X
- OpenAlex
- W2101198566
- Cited by
- 71
- References
- 3
- FWCI
- 7.14
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.