Rodriguez-Gonzalez, Carmen Guadalupe, Herranz-Alonso, Ana, Martin-Barbero, Maria Luisa, Duran-Garcia, Esther, Durango-Limarquez, Maria Isabel, Hernández-Sampelayo, Paloma, Sanjurjo-Saez, Maria · 2012 · Journal of the American Medical Informatics Association
Cited by 71

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: To identify the frequency of medication administration errors and their potential risk factors in units using a computerized prescription order entry program and profiled automated dispensing cabinets. DESIGN: Prospective observational study conducted within two clinical units of the Gastroenterology Department in a 1537-bed tertiary teaching hospital in Madrid (Spain). MEASUREMENTS: Medication errors were measured using the disguised observation technique. Types of medication errors and their potential severity were described. The correlation between potential risk factors and medication errors was studied to identify potential causes. RESULTS: In total, 2314 medication administrations to 73 patients were observed: 509 errors were recorded (22.0%)-68 (13.4%) in preparation and 441 (86.6%) in administration. The most frequent errors were use of wrong administration techniques (especially concerning food intake (13.9%)), wrong reconstitution/dilution (1.7%), omission (1.4%), and wrong infusion speed (1.2%). Errors were classified as no damage (95.7%), no damage but monitoring required (2.3%), and temporary damage (0.4%). Potential clinical severity could not be assessed in 1.6% of cases. The potential risk factors morning shift, evening shift, Anatomical Therapeutic Chemical medication class antacids, prokinetics, antibiotics and immunosuppressants, oral administration, and intravenous administration were associated with a higher risk of administration errors. No association was found with variables related to understaffing or nurse's experience. CONCLUSIONS: Medication administration errors persist in units with automated prescription and dispensing. We identified a need to improve nurses' working procedures and to implement a Clinical Decision Support tool that generates recommendations about scheduling according to dietary restrictions, preparation of medication before parenteral administration, and adequate infusion rates.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/amiajnl-2011-000332

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 71

Metadata

Authors
Rodriguez-Gonzalez, C. G., Herranz-Alonso, A., Martin-Barbero, M. L., Duran-Garcia, E., Durango-Limarquez, M. I., Hernández-Sampelayo, P., & Sanjurjo-Saez, M.
Venue
Journal of the American Medical Informatics Association
Published
2012-01
Volume
19
Issue
1
Pages
72-78
ISSN
  • 1067-5027 (ISSN-L)
  • 1527-974X
OpenAlex
W2101198566
Cited by
71
References
3
FWCI
7.14
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.