CoChat

Developing a natural language processing application for measuring the quality of colonoscopy procedures

Open access
Harkema, Henk, Chapman, Wendy W, Saul, Melissa, Dellon, Evan S, Schoen, Robert E, Mehrotra, Ateev · 2011 · Journal of the American Medical Informatics Association
Cited by 95

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: The quality of colonoscopy procedures for colorectal cancer screening is often inadequate and varies widely among physicians. Routine measurement of quality is limited by the costs of manual review of free-text patient charts. Our goal was to develop a natural language processing (NLP) application to measure colonoscopy quality. MATERIALS AND METHODS: Using a set of quality measures published by physician specialty societies, we implemented an NLP engine that extracts 21 variables for 19 quality measures from free-text colonoscopy and pathology reports. We evaluated the performance of the NLP engine on a test set of 453 colonoscopy reports and 226 pathology reports, considering accuracy in extracting the values of the target variables from text, and the reliability of the outcomes of the quality measures as computed from the NLP-extracted information. RESULTS: The average accuracy of the NLP engine over all variables was 0.89 (range: 0.62-1.0) and the average F measure over all variables was 0.74 (range: 0.49-0.89). The average agreement score, measured as Cohen's κ, between the manually established and NLP-derived outcomes of the quality measures was 0.62 (range: 0.09-0.86). DISCUSSION: For nine of the 19 colonoscopy quality measures, the agreement score was 0.70 or above, which we consider a sufficient score for the NLP-derived outcomes of these measures to be practically useful for quality measurement. CONCLUSION: The use of NLP for information extraction from free-text colonoscopy and pathology reports creates opportunities for large scale, routine quality measurement, which can support quality improvement in colonoscopy care.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/amiajnl-2011-000431

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 95

Metadata

Authors
Harkema, H., Chapman, W. W., Saul, M., Dellon, E. S., Schoen, R. E., & Mehrotra, A.
Venue
Journal of the American Medical Informatics Association
Published
2011-09-21
Volume
18
Issue
Supplement_1
Pages
i150-i156
ISSN
  • 1067-5027 (ISSN-L)
  • 1527-974X
OpenAlex
W2136552597
Cited by
95
References
6
FWCI
2.48
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Developing a natural language processing application for measuring the quality of colonoscopy procedures. https://app.cochat.ai/papers/10.1136/amiajnl-2011-000431
The paper
Harkema, H., Chapman, W. W., Saul, M., Dellon, E. S., Schoen, R. E., & Mehrotra, A. (2011). Developing a natural language processing application for measuring the quality of colonoscopy procedures. Journal of the American Medical Informatics Association. https://doi.org/10.1136/amiajnl-2011-000431

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.