Developing a natural language processing application for measuring the quality of colonoscopy procedures
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: The quality of colonoscopy procedures for colorectal cancer screening is often inadequate and varies widely among physicians. Routine measurement of quality is limited by the costs of manual review of free-text patient charts. Our goal was to develop a natural language processing (NLP) application to measure colonoscopy quality. MATERIALS AND METHODS: Using a set of quality measures published by physician specialty societies, we implemented an NLP engine that extracts 21 variables for 19 quality measures from free-text colonoscopy and pathology reports. We evaluated the performance of the NLP engine on a test set of 453 colonoscopy reports and 226 pathology reports, considering accuracy in extracting the values of the target variables from text, and the reliability of the outcomes of the quality measures as computed from the NLP-extracted information. RESULTS: The average accuracy of the NLP engine over all variables was 0.89 (range: 0.62-1.0) and the average F measure over all variables was 0.74 (range: 0.49-0.89). The average agreement score, measured as Cohen's κ, between the manually established and NLP-derived outcomes of the quality measures was 0.62 (range: 0.09-0.86). DISCUSSION: For nine of the 19 colonoscopy quality measures, the agreement score was 0.70 or above, which we consider a sufficient score for the NLP-derived outcomes of these measures to be practically useful for quality measurement. CONCLUSION: The use of NLP for information extraction from free-text colonoscopy and pathology reports creates opportunities for large scale, routine quality measurement, which can support quality improvement in colonoscopy care.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The quality of health care delivered to adults in the United States
McGlynn, E. A., Asch, S. M., Adams, J., Keesey, J., Hicks, J., DeCristofaro, A., & Kerr, E. A. (2003) · New England Journal of Medicine · doi:10.1056/nejmsa022615 · Cited by 5,079
Chaudhry, B., Wang, J., Wu, S., Maglione, M., Mojica, W., Roth, E., Morton, S. C., & Shekelle, P. G. (2006) · Annals of Internal Medicine · doi:10.7326/0003-4819-144-10-200605160-00125 · Cited by 3,159
Savova, G. K., Masanz, J. J., Ogren, P. V., Zheng, J., Sohn, S., Kipper-Schuler, K. C., & Chute, C. G. (2010) · Journal of the American Medical Informatics Association · doi:10.1136/jamia.2009.001560 · Cited by 1,967
Quality indicators for colonoscopy
Rex, D. K., Schoenfeld, P. S., Cohen, J., Pike, I. M., Adler, D. G., Fennerty, M. B., Lieb, J. G., Park, W. G., Rizk, M. K., Sawhney, M. S., et al. (2015) · Gastrointestinal Endoscopy · doi:10.1016/j.gie.2014.07.058 · Cited by 1,764
Improving Safety with Information Technology
Bates, D. W., & Gawande, A. A. (2003) · New England Journal of Medicine · doi:10.1056/nejmsa020847 · Cited by 1,544
Tang, P. C., Ralston, M., Arrigotti, M. F., Qureshi, L., & Graham, J. (2007) · Journal of the American Medical Informatics Association · doi:10.1197/jamia.m2198 · Cited by 193
Cited by
Text mining of cancer-related information: Review of current status and future directions
Spasić, I., Livsey, J., Keane, J. A., & Nenadić, G. (2014) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2014.06.009 · Cited by 207
Clinical Data Reuse or Secondary Use: Current Status and Potential Future Progress
Meystre, S. M., Lovis, C., Bürkle, T., Tognola, G., Budrionis, A., & Lehmann, C. U. (2017) · Yearbook of Medical Informatics · doi:10.15265/iy-2017-007 · Cited by 204
Clinical research informatics: a conceptual perspective
Kahn, M. G., & Weng, C. (2012) · Journal of the American Medical Informatics Association · doi:10.1136/amiajnl-2012-000968 · Cited by 40
Deep learning approach to detection of colonoscopic information from unstructured reports
Seong, D., Choi, Y. H., Shin, S.-Y., & Yi, B.-K. (2023) · BMC Medical Informatics and Decision Making · doi:10.1186/s12911-023-02121-7 · Cited by 16
“[51] GATE [52] Statistical NLP (NLP framework)”
Metadata
- Authors
- Harkema, H., Chapman, W. W., Saul, M., Dellon, E. S., Schoen, R. E., & Mehrotra, A.
- Venue
- Journal of the American Medical Informatics Association
- Publisher
- Oxford University Press (OUP)
- Published
- 2011-09-21
- Volume
- 18
- Issue
- Supplement_1
- Pages
- i150-i156
- ISSN
- 1067-5027 (ISSN-L)
- 1527-974X
- OpenAlex
- W2136552597
- Cited by
- 95
- References
- 6
- FWCI
- 2.48
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Developing a natural language processing application for measuring the quality of colonoscopy procedures. https://app.cochat.ai/papers/10.1136/amiajnl-2011-000431
- The paper
- Harkema, H., Chapman, W. W., Saul, M., Dellon, E. S., Schoen, R. E., & Mehrotra, A. (2011). Developing a natural language processing application for measuring the quality of colonoscopy procedures. Journal of the American Medical Informatics Association. https://doi.org/10.1136/amiajnl-2011-000431
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.