The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Drug—drug interactions that should be non-interruptive in order to reduce alert fatigue in electronic health records
Open accessAbstract
OBJECTIVE: Alert fatigue represents a common problem associated with the use of clinical decision support systems in electronic health records (EHR). This problem is particularly profound with drug-drug interaction (DDI) alerts for which studies have reported override rates of approximately 90%. The objective of this study is to report consensus-based recommendations of an expert panel on DDI that can be safely made non-interruptive to the provider's workflow, in EHR, in an attempt to reduce alert fatigue. METHODS: We utilized an expert panel process to rate the interactions. Panelists had expertise in medicine, pharmacy, pharmacology and clinical informatics, and represented both academic institutions and vendors of medication knowledge bases and EHR. In addition, representatives from the US Food and Drug Administration and the American Society of Health-System Pharmacy contributed to the discussions. RESULTS: Recommendations and considerations of the panel resulted in the creation of a list of 33 class-based low-priority DDI that do not warrant being interruptive alerts in EHR. In one institution, these accounted for 36% of the interactions displayed. DISCUSSION: Development and customization of the content of medication knowledge bases that drive DDI alerting represents a resource-intensive task. Creation of a standardized list of low-priority DDI may help reduce alert fatigue across EHR. CONCLUSIONS: Future efforts might include the development of a consortium to maintain this list over time. Such a list could also be used in conjunction with financial incentives tied to its adoption in EHR.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“It is widely accepted that “alert fatigue” explains high override rates [7, 9–14].”
From Effects of workload, work complexity, and repeated alerts on alert fatigue in a clinical decision support system (2017) · cites this paper as [14]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Prior research has found that there are opportunities for improving or turning off CDS alerts to improve patient outcomes.25–28”
From Clinician collaboration to improve clinical decision support: the Clickbusters initiative (2022) · cites this paper as [26]
Experimental — accuracy not yet measuredIn the citing paper
“Rejection bias refers to the conscious or unconscious desensitization to excessive alerts. Alert fatigue is a manifestation of this bias, as clinicians may ignore important alerts owing to an overwhelming number of false alarms [81, 82].”
From Fairness of artificial intelligence in healthcare: review and recommendations (2024) · cites this paper as [82]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Institute for Safe Medication Practices
Cohen, M. R. (2002) · Encyclopedia of Clinical Pharmacy · doi:10.3109/9780824706081.079 · Cited by 1,205
Overriding of Drug Safety Alerts in Computerized Physician Order Entry
van der Sijs, H., Aarts, J., Vulto, A., & Berg, M. (2006) · Journal of the American Medical Informatics Association · doi:10.1197/jamia.m1809 · Cited by 1,117
Medication-related clinical decision support in computerized provider order entry systems: a review
Kuperman, G. J., Bobb, A., Payne, T. H., Avery, A. J., Gandhi, T. K., Burns, G., Classen, D. C., & Bates, D. W. (2007) · Journal of the American Medical Informatics Association · doi:10.1197/jamia.m2170 · Cited by 763
Self-citationOverrides of Medication Alerts in Ambulatory Care
Isaac, T., Weissman, J. S., Davis, R. B., Massagli, M., Cyrulik, A., Sands, D. Z., & Weingart, S. N. (2009) · Archives of Internal Medicine · doi:10.1001/archinternmed.2008.551 · Cited by 309
Kesselheim, A. S., Cresswell, K., Phansalkar, S., Bates, D. W., & Sheikh, A. (2011) · Health Affairs · doi:10.1377/hlthaff.2010.1111 · Cited by 277
Self-citationSchedlbauer, A., Prasad, V., Mulvaney, C., Phansalkar, S., Stanton, W., Bates, D. W., & Avery, A. J. (2009) · Journal of the American Medical Informatics Association · doi:10.1197/jamia.m2910 · Cited by 262
Self-citationClinical Relevance of Drug-Drug Interactions: A Structured Assessment Procedure
van Roon, E. N., Flikweert, S., le Comte, M., Langendijk, P. N. J., Kwee-Zuiderwijk, W. J. M., Smits, P., & Brouwers, J. R. B. J. (2005) · Drug Safety · doi:10.2165/00002018-200528120-00007 · Cited by 181
Turning Off Frequently Overridden Drug Alerts: Limited Opportunities for Doing It Safely
van der Sijs, H., Aarts, J., van Gelder, T., Berg, M., & Vulto, A. (2008) · Journal of the American Medical Informatics Association · doi:10.1197/jamia.m2311 · Cited by 175
Performance of Community Pharmacy Drug Interaction Software
Hazlet, T. K., Lee, T. A., Hansten, P. D., & Horn, J. R. (2001) · Journal of the American Pharmaceutical Association (1996) · doi:10.1016/s1086-5802(16)31230-x · Cited by 141
High-priority drug–drug interactions for use in electronic health records
Phansalkar, S., Desai, A. A., Bell, D., Yoshida, E., Doole, J., Czochanski, M., Middleton, B., & Bates, D. W. (2012) · Journal of the American Medical Informatics Association · doi:10.1136/amiajnl-2011-000612 · Cited by 134
Self-citation
Cited by
Key challenges for delivering clinical impact with artificial intelligence
Kelly, C. J., Karthikesalingam, A., Suleyman, M., Corrado, G., & King, D. (2019) · BMC Medicine · doi:10.1186/s12916-019-1426-2 · Cited by 3,136
with the HITEC Investigators, Ancker, J. S., Edwards, A., Nosal, S., Hauser, D., Mauer, E., & Kaushal, R. (2017) · BMC Medical Informatics and Decision Making · doi:10.1186/s12911-017-0430-8 · Cited by 709
Fairness of artificial intelligence in healthcare: review and recommendations
Ueda, D., Kakinuma, T., Fujita, S., Kamagata, K., Fushimi, Y., Ito, R., Matsui, Y., Nozaki, T., Nakaura, T., Fujima, N., et al. (2024) · Japanese Journal of Radiology · doi:10.1007/s11604-023-01474-3 · Cited by 607
“Alert fatigue is a manifestation of this bias, as clini‑ cians may ignore important alerts owing to an overwhelm‑ ing number of false alarms [81, 82].”
BackgroundFraming the challenges of artificial intelligence in medicine
Yu, K.-H., & Kohane, I. S. (2019) · BMJ Quality & Safety · doi:10.1136/bmjqs-2018-008551 · Cited by 233
Overrides of medication-related clinical decision support alerts in outpatients
Nanji, K. C., Slight, S. P., Seger, D. L., Cho, I., Fiskio, J. M., Redden, L. M., Volk, L. A., & Bates, D. W. (2014) · Journal of the American Medical Informatics Association · doi:10.1136/amiajnl-2013-001813 · Cited by 219
Self-citation
Metadata
- Authors
- Phansalkar, S., van der Sijs, H., Tucker, A. D., Desai, A. A., Bell, D. S., Teich, J. M., Middleton, B., & Bates, D. W.
- Affiliations
- Brigham and Women's Hospital (US)
- RAND Corporation (US)
- Venue
- Journal of the American Medical Informatics Association
- Publisher
- Oxford University Press (OUP)
- Published
- 2012-09-25
- Volume
- 20
- Issue
- 3
- Pages
- 489-493
- ISSN
- 1067-5027 (ISSN-L)
- 1527-974X
- PMC
- PMC3628052
- OpenAlex
- W1897770946
- Cited by
- 239
- References
- 25
- Citations by year
- 2026: 15 · 2025: 13 · 2024: 16 · 2023: 17 · 2022: 23 · 2021: 18 · 2020: 12 · 2019: 22 · 2018: 11 · 2017: 17 · 2016: 25 · 2015: 25 · 2014: 15 · 2013: 9 · 2012: 1
- FWCI
- 26.01
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Journal of the American Medical Informatics Association (publishedVersion)
- Europe PMC (PubMed Central) (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- EUR Research Repository (Erasmus University Rotterdam) (publishedVersion)
- EUR Research Repository (Erasmus University Rotterdam) (submittedVersion)
- RePub (Erasmus University Rotterdam) (submittedVersion, other-oa)
- Topics
- Health Sciences › Health Professions › Health Information Management › Electronic Health Records Systems
- Health Sciences › Medicine › Geriatrics and Gerontology › Pharmaceutical Practices and Patient Outcomes
- Health Sciences › Medicine › Surgery › Healthcare Technology and Patient Monitoring
- Keywords
- drug-drug interactions, alarm fatigue, clinical decision support, electronic health records, clinical workflow, expert panel recommendations
- MeSH terms
- Drug Interactions, Drug Therapy, Computer-Assisted, Humans, Decision Support Systems, Clinical, Medical Order Entry Systems, Workflow, Electronic Health Records
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Drug—drug interactions that should be non-interruptive in order to reduce alert fatigue in electronic health records. https://app.cochat.ai/papers/10.1136/amiajnl-2012-001089
- The paper
- Phansalkar, S., van der Sijs, H., Tucker, A. D., Desai, A. A., Bell, D. S., Teich, J. M., Middleton, B., & Bates, D. W. (2013). Drug—drug interactions that should be non-interruptive in order to reduce alert fatigue in electronic health records. Journal of the American Medical Informatics Association. https://doi.org/10.1136/amiajnl-2012-001089
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.