The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Syndromic surveillance for health information system failures: a feasibility study
Open accessAbstract
OBJECTIVE: To explore the applicability of a syndromic surveillance method to the early detection of health information technology (HIT) system failures. METHODS: A syndromic surveillance system was developed to monitor a laboratory information system at a tertiary hospital. Four indices were monitored: (1) total laboratory records being created; (2) total records with missing results; (3) average serum potassium results; and (4) total duplicated tests on a patient. The goal was to detect HIT system failures causing: data loss at the record level; data loss at the field level; erroneous data; and unintended duplication of data. Time-series models of the indices were constructed, and statistical process control charts were used to detect unexpected behaviors. The ability of the models to detect HIT system failures was evaluated using simulated failures, each lasting for 24 h, with error rates ranging from 1% to 35%. RESULTS: In detecting data loss at the record level, the model achieved a sensitivity of 0.26 when the simulated error rate was 1%, while maintaining a specificity of 0.98. Detection performance improved with increasing error rates, achieving a perfect sensitivity when the error rate was 35%. In the detection of missing results, erroneous serum potassium results and unintended repetition of tests, perfect sensitivity was attained when the error rate was as small as 5%. Decreasing the error rate to 1% resulted in a drop in sensitivity to 0.65-0.85. CONCLUSIONS: Syndromic surveillance methods can potentially be applied to monitor HIT systems, to facilitate the early detection of failures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The synthesis of findings across investigations, such as national thematic reviews, demonstrates the value of aggregating insights to identify recurrent patterns of risk that may not be apparent within single organisations (1, 63, 64).”
From Why digital health fails silently: a sociotechnical theory of health information technology–related risk (2026) · cites this paper as [64]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Breitung, J., & Hamilton, J. D. (1995) · Contemporary Sociology · doi:10.2307/2076916 · Cited by 10,966
Booth, D. E. (1997) · Technometrics · doi:10.1080/00401706.1997.10485448 · Cited by 3,201
Statistical process control as a tool for research and healthcare improvement
Benneyan, J. C. (2003) · Quality and Safety in Health Care · doi:10.1136/qhc.12.6.458 · Cited by 1,045
Microbial Threats to Health: Emergence, Detection, and Response
Smolinski, M. S., Hamburg, M. A., & Lederberg, J. (2003) · Cited by 615
Health IT and Patient Safety: Building Safer Systems for Better Care
Chou, D. (2012) · JAMA · doi:10.1001/jama.308.21.2282-a · Cited by 503
Measuring errors and adverse events in health care
Thomas, E. J., & Petersen, L. A. (2003) · Journal of General Internal Medicine · doi:10.1046/j.1525-1497.2003.20147.x · Cited by 455
Implementing Syndromic Surveillance: A Practical Guide Informed by the Early Experience
Mandl, K. D. (2003) · Journal of the American Medical Informatics Association · doi:10.1197/jamia.m1356 · Cited by 410
Time series modeling for syndromic surveillance
Reis, B. Y., & Mandl, K. D. (2003) · BMC Medical Informatics and Decision Making · doi:10.1186/1472-6947-3-2 · Cited by 254
Using FDA reports to inform a classification for health information technology safety problems
Magrabi, F., Ong, M.-S., Runciman, W., & Coiera, E. (2012) · Journal of the American Medical Informatics Association · doi:10.1136/amiajnl-2011-000369 · Cited by 193
Self-citationError log analysis: statistical modeling and heuristic trend analysis
Lin, T.-T. Y., & Siewiorek, D. P. (1990) · IEEE Transactions on Reliability · doi:10.1109/24.58720 · Cited by 184
Research works printed but not linked: 4
- 2011, Journal of the American Medical Informatics Association, 19, 45
- 2009, 21, 52
- 2004, CHANCE, 17, 19
- 2003, CDC MORB MORTAL WKLY REP, 53, 5
Cited by
The unintended consequences of health information technology revisited
Ash, J., Berg, M., & Coiera, E. (2016) · Yearbook of Medical Informatics · doi:10.15265/iy-2016-014 · Cited by 101
“Real-time monitoring of clinical information systems has the potential to identify system downtimes and periods of network congestion that may risk patient care [35].”
Self-citationThe Last Mile: Where Artificial Intelligence Meets Reality
Coiera, E. (2019) · Journal of Medical Internet Research · doi:10.2196/16323 · Cited by 102
Self-citationYusof, M. M. (2015) · International Journal of Medical Informatics · doi:10.1016/j.ijmedinf.2015.03.001 · Cited by 114
Magrabi, F., Liaw, S. T., Arachi, D., Runciman, W. B., Coiera, E. W., & Kidd, M. R. (2015) · BMJ Quality & Safety · doi:10.1136/bmjqs-2015-004323 · Cited by 72
Self-citationTechnology, cognition and error
Coiera, E. W. (2015) · BMJ Quality & Safety · doi:10.1136/bmjqs-2014-003484 · Cited by 55
Self-citation
Metadata
- Authors
- Ong, M.-S., Magrabi, F., & Coiera, E.
- Affiliations
- UNSW Sydney (AU)
- Corresponding author
- Ong, M.-S.
- Venue
- Journal of the American Medical Informatics Association
- Publisher
- Oxford University Press (OUP)
- Published
- 2013-05-01
- Volume
- 20
- Issue
- 3
- Pages
- 506-512
- ISSN
- 1067-5027 (ISSN-L)
- 1527-974X
- PMC
- PMC3628054
- OpenAlex
- W2106720074
- Cited by
- 22
- References
- 24
- Citations by year
- 2026: 2 · 2024: 1 · 2022: 3 · 2020: 1 · 2019: 1 · 2017: 2 · 2016: 4 · 2015: 5 · 2014: 2 · 2013: 1
- FWCI
- 1.91
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Journal of the American Medical Informatics Association (publishedVersion, public-domain)
- Europe PMC (PubMed Central) (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Funders
- University of New South Wales
- National Health and Medical Research Council
- Topics
- Health Sciences › Medicine › Epidemiology › Data-Driven Disease Surveillance
- Health Sciences › Health Professions › Health Information Management › Electronic Health Records Systems
- Health Sciences › Medicine › Surgery › Healthcare Technology and Patient Monitoring
- Keywords
- syndromic surveillance, laboratory information systems, early failure detection, data loss, control charts, time series models, sensitivity and specificity
- MeSH terms
- Algorithms, Clinical Laboratory Information Systems, Computer Simulation, Feasibility Studies, Humans, Medical Informatics, Models, Theoretical, Population Surveillance, Equipment Failure Analysis, Health Information Systems
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Syndromic surveillance for health information system failures: a feasibility study. https://app.cochat.ai/papers/10.1136/amiajnl-2012-001144
- The paper
- Ong, M.-S., Magrabi, F., & Coiera, E. (2013). Syndromic surveillance for health information system failures: a feasibility study. Journal of the American Medical Informatics Association. https://doi.org/10.1136/amiajnl-2012-001144
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.