CoChat

Syndromic surveillance for health information system failures: a feasibility study

Open access
Ong, M.-S., Magrabi, F., Coiera, E. · 2013 · Journal of the American Medical Informatics Association

The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: To explore the applicability of a syndromic surveillance method to the early detection of health information technology (HIT) system failures. METHODS: A syndromic surveillance system was developed to monitor a laboratory information system at a tertiary hospital. Four indices were monitored: (1) total laboratory records being created; (2) total records with missing results; (3) average serum potassium results; and (4) total duplicated tests on a patient. The goal was to detect HIT system failures causing: data loss at the record level; data loss at the field level; erroneous data; and unintended duplication of data. Time-series models of the indices were constructed, and statistical process control charts were used to detect unexpected behaviors. The ability of the models to detect HIT system failures was evaluated using simulated failures, each lasting for 24 h, with error rates ranging from 1% to 35%. RESULTS: In detecting data loss at the record level, the model achieved a sensitivity of 0.26 when the simulated error rate was 1%, while maintaining a specificity of 0.98. Detection performance improved with increasing error rates, achieving a perfect sensitivity when the error rate was 35%. In the detection of missing results, erroneous serum potassium results and unintended repetition of tests, perfect sensitivity was attained when the error rate was as small as 5%. Decreasing the error rate to 1% resulted in a drop in sensitivity to 0.65-0.85. CONCLUSIONS: Syndromic surveillance methods can potentially be applied to monitor HIT systems, to facilitate the early detection of failures.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/amiajnl-2012-001144

Cites

25 of 25 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 8

  1. Magrabi F, Ong MS, Runciman W, et al. An analysis of computer-related patient safety incidents to inform the development of a classification. J Am Med Inform Assoc 2010;17:663–70 [DOI] [PMC free article] [PubMed] [Google Scholar]
  2. 2011, Journal of the American Medical Informatics Association, 19, 45
  3. Dunn JE. Mystery virus disrupts New Zealand ambulance service. TechWorld, 2011. http://news.techworld.com/security/3318106/mystery-virus-disrupts-new-zealand-ambulance-service (accessed 5 Jun 2012). [Google Scholar]
  4. Williams M, Anderson J. Ambulances turned away as computer virus infects Gwinnett Medical Center computers. Gwinnett County News, 2011. http://www.ajc.com/news/gwinnett/ambulances-turned-away-as-1255750.html (accessed 5 Jun 2012). [Google Scholar]
  5. Rouse WB. Health care as a complex adaptive system: implications for design and management. In: Compton WD, Reid P, eds. The bridge: linking engineering and society. Washington, DC: National Academy of Sciences, 2008:17–25 [Google Scholar]
  6. Coiera E, Aarts J, Kulikowski C. The dangerous decade. J Am Med Inform Assoc 2012;19:2–5 [DOI] [PMC free article] [PubMed] [Google Scholar]
  7. Mandl KD, Overhage JM, Wagner MM, et al. Implementing syndromic surveillance: a practical guide informed by the early experience. J Am Med Inform Assoc 2004;11:141–50 [DOI] [PMC free article] [PubMed] [Google Scholar]
  8. Henning KJ. Overview of syndromic surveillance. What is syndromic surveillance? CDC Morb Mortal Wkly Rep 2003;53(Suppl.):5–11 [Google Scholar]

Cited by

See all 22

Metadata

Authors
Ong, M.-S., Magrabi, F., & Coiera, E.
Affiliations
UNSW Sydney (AU)
Corresponding author
Ong, M.-S.
Venue
Journal of the American Medical Informatics Association
Published
2013-05-01
Volume
20
Issue
3
Pages
506-512
ISSN
  • 1067-5027 (ISSN-L)
  • 1527-974X
OpenAlex
W2106720074
Cited by
22
References
24
Citations by year
2026: 2 · 2024: 1 · 2022: 3 · 2020: 1 · 2019: 1 · 2017: 2 · 2016: 4 · 2015: 5 · 2014: 2 · 2013: 1
FWCI
1.91
Type
journal article
Language
en
Open access
Locations
  • Journal of the American Medical Informatics Association (publishedVersion, public-domain)
  • Europe PMC (PubMed Central) (publishedVersion)
  • PubMed Central (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • University of New South Wales
  • National Health and Medical Research Council
Topics
  • Health Sciences › Medicine › Epidemiology › Data-Driven Disease Surveillance
  • Health Sciences › Health Professions › Health Information Management › Electronic Health Records Systems
  • Health Sciences › Medicine › Surgery › Healthcare Technology and Patient Monitoring
Keywords
syndromic surveillance, laboratory information systems, early failure detection, data loss, control charts, time series models, sensitivity and specificity
MeSH terms
Algorithms, Clinical Laboratory Information Systems, Computer Simulation, Feasibility Studies, Humans, Medical Informatics, Models, Theoretical, Population Surveillance, Equipment Failure Analysis, Health Information Systems

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.