The safety of electronic prescribing: manifestations, mechanisms, and rates of system-related errors associated with two commercial systems in hospitals
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
OBJECTIVES: To compare the manifestations, mechanisms, and rates of system-related errors associated with two electronic prescribing systems (e-PS). To determine if the rate of system-related prescribing errors is greater than the rate of errors prevented. METHODS: Audit of 629 inpatient admissions at two hospitals in Sydney, Australia using the CSC MedChart and Cerner Millennium e-PS. System related errors were classified by manifestation (eg, wrong dose), mechanism, and severity. A mechanism typology comprised errors made: selecting items from drop-down menus; constructing orders; editing orders; or failing to complete new e-PS tasks. Proportions and rates of errors by manifestation, mechanism, and e-PS were calculated. RESULTS: 42.4% (n=493) of 1164 prescribing errors were system-related (78/100 admissions). This result did not differ by e-PS (MedChart 42.6% (95% CI 39.1 to 46.1); Cerner 41.9% (37.1 to 46.8)). For 13.4% (n=66) of system-related errors there was evidence that the error was detected prior to study audit. 27.4% (n=135) of system-related errors manifested as timing errors and 22.5% (n=111) wrong drug strength errors. Selection errors accounted for 43.4% (34.2/100 admissions), editing errors 21.1% (16.5/100 admissions), and failure to complete new e-PS tasks 32.0% (32.0/100 admissions). MedChart generated more selection errors (OR=4.17; p=0.00002) but fewer new task failures (OR=0.37; p=0.003) relative to the Cerner e-PS. The two systems prevented significantly more errors than they generated (220/100 admissions (95% CI 180 to 261) vs 78 (95% CI 66 to 91)). CONCLUSIONS: System-related errors are frequent, yet few are detected. e-PS require new tasks of prescribers, creating additional cognitive load and error opportunities. Dual classification, by manifestation and mechanism, allowed identification of design features which increase risk and potential solutions. e-PS designs with fewer drop-down menu selections may reduce error risk.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ash, J. S. (2003) · Journal of the American Medical Informatics Association · doi:10.1197/jamia.m1471 · Cited by 1,789
Types of Unintended Consequences Related to Computerized Provider Order Entry
Campbell, E. M., Sittig, D. F., Ash, J. S., Guappone, K. P., & Dykstra, R. H. (2006) · Journal of the American Medical Informatics Association · doi:10.1197/jamia.m2042 · Cited by 823
Health IT and Patient Safety: Building Safer Systems for Better Care
Chou, D. (2012) · JAMA · doi:10.1001/jama.308.21.2282-a · Cited by 503
Using FDA reports to inform a classification for health information technology safety problems
Magrabi, F., Ong, M.-S., Runciman, W., & Coiera, E. (2012) · Journal of the American Medical Informatics Association · doi:10.1136/amiajnl-2011-000369 · Cited by 193
"e-Iatrogenesis": The Most Critical Unintended Consequence of CPOE and other HIT
Weiner, J. P., Kfuri, T., Chan, K., & Fowles, J. B. (2007) · Journal of the American Medical Informatics Association · doi:10.1197/jamia.m2338 · Cited by 189
Singh, H., Mani, S., Espadas, D., Petersen, N., Franklin, V., & Petersen, L. A. (2009) · Archives of Internal Medicine · doi:10.1001/archinternmed.2009.102 · Cited by 104
Safe Electronic Health Record Use Requires a Comprehensive Monitoring and Evaluation Framework
Sittig, D. F. (2010) · JAMA · doi:10.1001/jama.2010.61 · Cited by 76
Cited by
Kim, M. O., Coiera, E., & Magrabi, F. (2017) · Journal of the American Medical Informatics Association · doi:10.1093/jamia/ocw154 · Cited by 263
“For example, free-text fields were used to enter complex medication regimens when there were difficulties using CPOE systems.(27,41) Another commonly reported strategy was to revert to paper, creating a hybrid record system (15%, n1⁄45).”
BackgroundMethodThe unintended consequences of health information technology revisited
Ash, J., Berg, M., & Coiera, E. (2016) · Yearbook of Medical Informatics · doi:10.15265/iy-2016-014 · Cited by 101
“Using a standardized workflow measurement tool and error categorization scheme, Westbrook and colleagues undertook detailed analyses of medication error rates before and after the introduction of a CPOE system in two hospitals [33 34].”
Kaufman, D. R., Sheehan, B., Stetson, P., Bhatt, A. R., Field, A. I., Patel, C., & Maisel, J. M. (2016) · JMIR Medical Informatics · doi:10.2196/medinform.5544 · Cited by 58
“Problems associated with usability impact not only the quality of patient records but can even contribute to compromised patient safety [9,10].”
BackgroundLearning from errors: analysis of medication order voiding in CPOE systems
Kannampallil, T. G., Abraham, J., Solotskaya, A., Philip, S. G., Lambert, B. L., Schiff, G. D., Wright, A., & Galanter, W. L. (2017) · Journal of the American Medical Informatics Association · doi:10.1093/jamia/ocw187 · Cited by 18
Metadata
- Authors
- Westbrook, J. I., Baysari, M. T., Li, L., Burke, R., Richardson, K. L., & Day, R. O.
- Venue
- Journal of the American Medical Informatics Association
- Publisher
- Oxford University Press (OUP)
- Published
- 2013-11
- Volume
- 20
- Issue
- 6
- Pages
- 1159-1167
- ISSN
- 1067-5027 (ISSN-L)
- 1527-974X
- OpenAlex
- W2169215518
- Cited by
- 113
- References
- 7
- FWCI
- 12.50
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The safety of electronic prescribing: manifestations, mechanisms, and rates of system-related errors associated with two commercial systems in hospitals. https://app.cochat.ai/papers/10.1136/amiajnl-2013-001745
- The paper
- Westbrook, J. I., Baysari, M. T., Li, L., Burke, R., Richardson, K. L., & Day, R. O. (2013). The safety of electronic prescribing: manifestations, mechanisms, and rates of system-related errors associated with two commercial systems in hospitals. Journal of the American Medical Informatics Association. https://doi.org/10.1136/amiajnl-2013-001745
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.