Pulse oximetry as a screening tool for detecting major congenital heart defects in Indian newborns
The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
Objective: To evaluate the use of pulse oximetry as a screening tool for detecting major congenital heart defects (CHDs) in Indian newborns. Design: Cross-sectional observational study. Patients: In a community hospital of north India, babies born during a specific 8 h period of the day were recruited over a period of 3 years. Newborns with incomplete documentation were excluded. Intervention: Routine clinical examination, pulse oximetry and bedside echocardiography. Outcome measures: Any abnormalities in clinical examination and pulse oximetry were recorded. CHDs were diagnosed using bedside echocardiography. Accuracy of pulse oximetry, clinical examination and their combination for detecting major CHDs was calculated. Results: Among the 19 009 newborns screened, 70 had major CHDs at birth (44 serious, 26 critical). Pulse oximetry detected 39 major (sensitivity 55.7%, 95% CI 44.1% to 66.8%; specificity 68.3%, 67.6% to 68.9%) and 22 critical CHDs (sensitivity 84.6%, 66.5% to 93.9%; specificity 68.3%, 67.6% to 68.9%). Addition of pulse oximetry to clinical examination significantly improved sensitivity for major CHDs (35.7% (25.5% to 47.4%) to 75.7% (64.5% to 85.3%), p<0.01) and critical CHDs (11.5% (4.0% to 29.0%) to 84.6% (66.5% to 93.9%), p<0.01). Conclusions: Pulse oximetry is a sensitive screening tool for detecting major CHDs in Indian newborns. It adds significant value to the current practice of using clinical examination as a sole screening tool for detecting major CHDs. However, specificity of pulse oximetry was much lower in our study. Possible reasons for low specificity could be non-repetition of pulse oximetry in newborns with initial lower saturations, high prevalence of infections and respiratory issues in our cohort and use of non-motion tolerant oximeter.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In this regard, simple solutions, such as the distribution of pulse oximeters to primary care physicians and local medical teams, may improve the detection of ToF.39”
From Tetralogy of Fallot in Low- and Middle-Income Countries (2024) · cites this paper as [39]
Citations
Cites
The incidence of congenital heart disease.
Hoffman, J. I. E., & Kaplan, S. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)01886-7 · Cited by 6,099
Birth prevalence of congenital heart disease worldwide
van der Linde, D., Konings, E. E. M., Slager, M. A., Witsenburg, M., Helbing, W. A., Takkenberg, J. J. M., & Roos-Hesselink, J. W. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.08.025 · Cited by 3,452
Improved Surgical Outcome After Fetal Diagnosis of Hypoplastic Left Heart Syndrome
Tworetzky, W., McElhinney, D. B., Reddy, V. M., Brook, M. M., Hanley, F. L., & Silverman, N. H. (2001) · Circulation · doi:10.1161/01.cir.103.9.1269 · Cited by 681
Racial and Temporal Variations in the Prevalence of Heart Defects
Botto, L. D., Correa, A., & Erickson, J. D. (2001) · Pediatrics · doi:10.1542/peds.107.3.e32 · Cited by 566
de-Wahl Granelli, A., Wennergren, M., Sandberg, K., Mellander, M., Bejlum, C., Inganas, L., Eriksson, M., Segerdahl, N., Agren, A., Ekman-Joelsson, B.-M., et al. (2009) · BMJ · doi:10.1136/bmj.a3037 · Cited by 451
Strategies for Implementing Screening for Critical Congenital Heart Disease
Kemper, A. R., Mahle, W. T., Martin, G. R., Cooley, W. C., Kumar, P., Morrow, W. R., Kelm, K., Pearson, G. D., Glidewell, J., Grosse, S. D., et al. (2011) · Pediatrics · doi:10.1542/peds.2011-1317 · Cited by 424
Prenatal diagnosis of coarctation of the aorta improves survival and reduces morbidity: Table 1
Franklin, O., Burch, M., Manning, N., Sleeman, K., Gould, S., & Archer, N. (2002) · Heart · doi:10.1136/heart.87.1.67 · Cited by 421
The global burden of congenital heart disease : review article
Hoffman, J. I. E. (2013) · Cardiovascular Journal Of Africa · doi:10.5830/cvja-2013-028 · Cited by 405
Thangaratinam, S., Brown, K., Zamora, J., Khan, K. S., & Ewer, A. K. (2012) · The Lancet · doi:10.1016/s0140-6736(12)60107-x · Cited by 402
Twenty-year trends in diagnosis of life-threatening neonatal cardiovascular malformations
Wren, C., Reinhardt, Z., & Khawaja, K. (2008) · Archives of Disease in Childhood - Fetal and Neonatal Edition · doi:10.1136/adc.2007.119032 · Cited by 326
Research works printed but not linked: 1
- 10.1080/08035250510039900 · doi:10.1080/08035250510039900
Cited by
Pulse oximetry screening for critical congenital heart defects
Plana, M. N., Zamora, J., Suresh, G., Fernandez-Pineda, L., Thangaratinam, S., & Ewer, A. K. (2018) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd011912.pub2 · Cited by 254
Congenital Heart Disease in India: A Status Report
Saxena, A. (2018) · Indian Pediatrics · doi:10.1007/s13312-018-1445-7 · Cited by 139
“Screening newborns with pulse oximetry to diagnose critical CHD should become a part of newborn care [37].”
BackgroundSelf-citationPulse Oximetry and Auscultation for Congenital Heart Disease Detection
Hu, X., Ma, X., Zhao, Q., Yan, W., Ge, X., Jia, B., Liu, F., Wu, L., Ye, M., Liang, X., et al. (2017) · PEDIATRICS · doi:10.1542/peds.2017-1154 · Cited by 69
Cheng, S., Heo, K., Joos, É., Vervoort, D., & Joharifard, S. (2023) · World Journal for Pediatric and Congenital Heart Surgery · doi:10.1177/21501351231204328 · Cited by 41
“6,38 However, the in context where pulse oximetry is unavailable, our review identi fi ed that engaging community health workers, nurses, medical of fi cers, and midwives to recognize heart murmurs can enhance early screening for CHD. 3,4,6,11,12,27,33,39,40 Zhao et al concluded that cardiac…”
BackgroundKumar, R. (2016) · Annals of Pediatric Cardiology · doi:10.4103/0974-2069.181499 · Cited by 24
“Given the improved sensitivity of combination of pulse oximeter screening with physical examination, it is perhaps appropriate to recommend both for the initial evaluation.[4] The specifics of the combined screening strategy will need to be tailored depending on who performs the initial test.”
Background
Metadata
- Authors
- Saxena, A., Mehta, A., Ramakrishnan, S., Sharma, M., Salhan, S., Kalaivani, M., & Juneja, R.
- Affiliations
- Department of Cardiology, All India Institute of Medical Sciences, New Delhi, India
- All India Institute of Medical Sciences (IN)
- Columbia Asia (IN)
- Hindu Rao Hospital (IN)
- Venue
- Archives of Disease in Childhood - Fetal and Neonatal Edition
- Publisher
- BMJ
- Published
- 2015-06-02
- Volume
- 100
- Issue
- 5
- Pages
- F416-F421
- ISSN
- 1359-2998 (ISSN-L)
- 1468-2052
- OpenAlex
- W2109136668
- Cited by
- 34
- References
- 29
- Citations by year
- 2026: 4 · 2025: 1 · 2024: 1 · 2023: 5 · 2022: 2 · 2021: 2 · 2020: 2 · 2019: 4 · 2018: 4 · 2017: 4 · 2016: 4 · 2015: 1
- FWCI
- 3.40
- Type
- journal article
- Language
- en
- Update notices
- correction (2016-02-18)
- Open access
- closed
- Locations
- Archives of Disease in Childhood Fetal & Neonatal (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Congenital Heart Disease Studies
- Health Sciences › Medicine › Pediatrics, Perinatology and Child Health › Cardiovascular Conditions and Treatments
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Cardiovascular and Diving-Related Complications
- Keywords
- pulse oximetry, major congenital heart defects, newborn screening, bedside echocardiography, physical examination, diagnostic accuracy, critical congenital heart disease, oxygen saturation
- MeSH terms
- Cross-Sectional Studies, Echocardiography, Heart Defects, Congenital, Humans, India, Infant, Newborn, Oximetry, Sensitivity and Specificity, Prevalence, Neonatal Screening
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Pulse oximetry as a screening tool for detecting major congenital heart defects in Indian newborns. https://app.cochat.ai/papers/10.1136/archdischild-2014-307485
- The paper
- Saxena, A., Mehta, A., Ramakrishnan, S., Sharma, M., Salhan, S., Kalaivani, M., & Juneja, R. (2015). Pulse oximetry as a screening tool for detecting major congenital heart defects in Indian newborns. Archives of Disease in Childhood - Fetal and Neonatal Edition. https://doi.org/10.1136/archdischild-2014-307485
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.