Pulse oximetry screening for critical congenital heart defects

Open access
Plana, Maria N, Zamora, Javier, Suresh, Gautham, Fernandez-Pineda, Luis, Thangaratinam, Shakila, Ewer, Andrew K · 2018 · Cochrane Database of Systematic Reviews

Abstract

BACKGROUND: Health outcomes are improved when newborn babies with critical congenital heart defects (CCHDs) are detected before acute cardiovascular collapse. The main screening tests used to identify these babies include prenatal ultrasonography and postnatal clinical examination; however, even though both of these methods are available, a significant proportion of babies are still missed. Routine pulse oximetry has been reported as an additional screening test that can potentially improve detection of CCHD. OBJECTIVES: • To determine the diagnostic accuracy of pulse oximetry as a screening method for detection of CCHD in asymptomatic newborn infants• To assess potential sources of heterogeneity, including:○ characteristics of the population: inclusion or exclusion of antenatally detected congenital heart defects;○ timing of testing: < 24 hours versus ≥ 24 hours after birth;○ site of testing: right hand and foot (pre-ductal and post-ductal) versus foot only (post-ductal);○ oxygen saturation: functional versus fractional;○ study design: retrospective versus prospective design, consecutive versus non-consecutive series; and○ risk of bias for the "flow and timing" domain of QUADAS-2. SEARCH METHODS: We searched the Cochrane Central Register of Controlled Trials (CENTRAL; 2017, Issue 2) in the Cochrane Library and the following databases: MEDLINE, Embase, the Cumulative Index to Nursing and Allied Health Literature (CINAHL), and Health Services Research Projects in Progress (HSRProj), up to March 2017. We searched the reference lists of all included articles and relevant systematic reviews to identify additional studies not found through the electronic search. We applied no language restrictions. SELECTION CRITERIA: We selected studies that met predefined criteria for design, population, tests, and outcomes. We included cross-sectional and cohort studies assessing the diagnostic accuracy of pulse oximetry screening for diagnosis of CCHD in term and late preterm asymptomatic newborn infants. We considered all protocols of pulse oximetry screening (eg, different saturation thresholds to define abnormality, post-ductal only or pre-ductal and post-ductal measurements, test timing less than or greater than 24 hours). Reference standards were diagnostic echocardiography (echocardiogram) and clinical follow-up, including postmortem findings, mortality, and congenital anomaly databases. DATA COLLECTION AND ANALYSIS: We extracted accuracy data for the threshold used in primary studies. We explored between-study variability and correlation between indices visually through use of forest and receiver operating characteristic (ROC) plots. We assessed risk of bias in included studies using the QUADAS-2 tool. We used the bivariate model to calculate random-effects pooled sensitivity and specificity values. We investigated sources of heterogeneity using subgroup analyses and meta-regression. MAIN RESULTS: Twenty-one studies met our inclusion criteria (N = 457,202 participants). Nineteen studies provided data for the primary analysis (oxygen saturation threshold < 95% or ≤ 95%; N = 436,758 participants). The overall sensitivity of pulse oximetry for detection of CCHD was 76.3% (95% confidence interval [CI] 69.5 to 82.0) (low certainty of the evidence). Specificity was 99.9% (95% CI 99.7 to 99.9), with a false-positive rate of 0.14% (95% CI 0.07 to 0.22) (high certainty of the evidence). Summary positive and negative likelihood ratios were 535.6 (95% CI 280.3 to 1023.4) and 0.24 (95% CI 0.18 to 0.31), respectively. These results showed that out of 10,000 apparently healthy late preterm or full-term newborn infants, six will have CCHD (median prevalence in our review). Screening by pulse oximetry will detect five of these infants as having CCHD and will miss one case. In addition, screening by pulse oximetry will falsely identify another 14 infants out of the 10,000 as having suspected CCHD when they do not have it.The false-positive rate for detection of CCHD was lower when newborn pulse oximetry was performed longer than 24 hours after birth than when it was performed within 24 hours (0.06%, 95% CI 0.03 to 0.13, vs 0.42%, 95% CI 0.20 to 0.89; P = 0.027).Forest and ROC plots showed greater variability in estimated sensitivity than specificity across studies. We explored heterogeneity by conducting subgroup analyses and meta-regression of inclusion or exclusion of antenatally detected congenital heart defects, timing of testing, and risk of bias for the "flow and timing" domain of QUADAS-2, and we did not find an explanation for the heterogeneity in sensitivity. AUTHORS' CONCLUSIONS: Pulse oximetry is a highly specific and moderately sensitive test for detection of CCHD with very low false-positive rates. Current evidence supports the introduction of routine screening for CCHD in asymptomatic newborns before discharge from the well-baby nursery.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1002/14651858.cd011912.pub2

Cites

68 of 68 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 68 references

Cited by

See all 254

Metadata

Authors
Plana, M. N., Zamora, J., Suresh, G., Fernandez-Pineda, L., Thangaratinam, S., & Ewer, A. K.
Venue
Cochrane Database of Systematic Reviews
Publisher
Wiley
Published
2018-03-01
Volume
2018
Issue
3
Pages
CD011912-CD011912
ISSN
  • 1361-6137 (ISSN-L)
  • 1465-1858
OpenAlex
W2794285671
Cited by
254
References
68
FWCI
16.02
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Pulse oximetry screening for critical congenital heart defects. https://app.cochat.ai/papers/10.1002/14651858.cd011912.pub2
The paper
Plana, M. N., Zamora, J., Suresh, G., Fernandez-Pineda, L., Thangaratinam, S., & Ewer, A. K. (2018). Pulse oximetry screening for critical congenital heart defects. Cochrane Database of Systematic Reviews. https://doi.org/10.1002/14651858.cd011912.pub2

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.