The DOI matches its Crossref record.
Reduced response of retinal vessel diameters to flicker stimulation in patients with diabetes
Open accessAbstract
BACKGROUND/AIM: Stimulation of the retina with flickering light increases retinal arterial and venous diameters in animals and humans, indicating a tight coupling between neural activity and blood flow. The aim of the present study was to investigate whether this response is altered in patients with insulin dependent diabetes mellitus. METHODS: 26 patients with diabetes mellitus with no or mild non-proliferative retinopathy and 26 age and sex matched healthy volunteers were included in the study. Retinal vessel diameters were measured continuously with the Zeiss retinal vessel analyser. During these measurements three episodes of square wave flicker stimulation periods (16, 32, and 64 seconds; 8 Hz) were applied through the illumination pathway of the vessel analyser. RESULTS: In retinal arteries, the response to stimulation with diffuse luminance flicker was significantly diminished in diabetic patients compared to healthy volunteers (ANOVA, p<0.0031). In non-diabetic controls flicker stimulation increased retinal arterial diameters by +1.6% (1.8%) (mean, p<0.001 v baseline), +2.8% (SD 2.2%) (p<0.001) and +2.8% (1.6%) (p<0.001) during 16, 32, and 64 seconds of flicker stimulation, respectively. In diabetic patients flicker had no effect on arterial vessel diameters: +0.1% (3.1%) (16 seconds, p = 0.9), +1.1% (2.7%) (32 seconds, p = 0.07), +1.0% (2.8%) (64 seconds, p = 0.1). In retinal veins, the response to flicker light was not significantly different in both groups. Retinal venous vessel diameters increased by +0.7% (1.6%) (16 seconds, p<0.05), +1.9% (2.3%) (32 seconds, p<0.001) and 1.7% (1.8%) (64 seconds, p<0.001) in controls during flicker stimulation. Again, no increase was observed in the patients group: +0.6% (2.4%), +0.5% (1.5%), and +1.2% (3.1%) (16, 32, and 64 seconds, respectively). CONCLUSION: Flicker responses of retinal arteries and veins are abnormally reduced in patients with IDDM with no or mild non-proliferative retinopathy. Whether this diminished response can be attributed to altered retinal vascular reactivity or to decreased neural activity has yet to be clarified.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Kur, J., Newman, E. A., & Chan-Ling, T. (2012) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2012.04.004 · Cited by 678
Regulation of retinal blood flow in health and disease
Pournaras, C. J., Rungger-Brändle, E., Riva, C. E., Hardarson, S. H., & Stefansson, E. (2008) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2008.02.002 · Cited by 618
Doppler Optical Coherence Tomography
Leitgeb, R. A., Werkmeister, R. M., Blatter, C., & Schmetterer, L. (2014) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2014.03.004 · Cited by 444
Astrocyte Regulation of Blood Flow in the Brain
MacVicar, B. A., & Newman, E. A. (2015) · Cold Spring Harbor Perspectives in Biology · doi:10.1101/cshperspect.a020388 · Cited by 420
Riva, C. E., Logean, E., & Falsini, B. (2005) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2004.07.002 · Cited by 265
Metadata
- Authors
- Garhofer, G.
- Venue
- British Journal of Ophthalmology
- Publisher
- BMJ
- Published
- 2004-07-01
- Volume
- 88
- Issue
- 7
- Pages
- 887-891
- ISSN
- 0007-1161 (ISSN-L)
- OpenAlex
- W2034671535
- Cited by
- 233
- References
- 0
- FWCI
- 5.08
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reduced response of retinal vessel diameters to flicker stimulation in patients with diabetes. https://app.cochat.ai/papers/10.1136/bjo.2003.033548
- The paper
- Garhofer, G. (2004). Reduced response of retinal vessel diameters to flicker stimulation in patients with diabetes. British Journal of Ophthalmology. https://doi.org/10.1136/bjo.2003.033548
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.