The DOI matches its Crossref record; 61 of the 61 references it cites were found in a registry or an index.
Doppler Optical Coherence Tomography
Open accessAbstract
Optical Coherence Tomography (OCT) has revolutionized ophthalmology. Since its introduction in the early 1990s it has continuously improved in terms of speed, resolution and sensitivity. The technique has also seen a variety of extensions aiming to assess functional aspects of the tissue in addition to morphology. One of these approaches is Doppler OCT (DOCT), which aims to visualize and quantify blood flow. Such extensions were already implemented in time domain systems, but have gained importance with the introduction of Fourier domain OCT. Nowadays phase-sensitive detection techniques are most widely used to extract blood velocity and blood flow from tissues. A common problem with the technique is that the Doppler angle is not known and several approaches have been realized to obtain absolute velocity and flow data from the retina. Additional studies are required to elucidate which of these techniques is most promising. In the recent years, however, several groups have shown that data can be obtained with high validity and reproducibility. In addition, several groups have published values for total retinal blood flow. Another promising application relates to non-invasive angiography. As compared to standard techniques such as fluorescein and indocyanine-green angiography the technique offers two major advantages: no dye is required and depth resolution is required is provided. As such Doppler OCT has the potential to improve our abilities to diagnose and monitor ocular vascular diseases.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Glial and neuronal control of brain blood flow
Attwell, D., Buchan, A. M., Charpak, S., Lauritzen, M., MacVicar, B. A., & Newman, E. A. (2010) · Nature · doi:10.1038/nature09613 · Cited by 2,511
Performance of fourier domain vs time domain optical coherence tomography
Leitgeb, R., Hitzenberger, C., & Fercher, A. (2003) · Optics Express · doi:10.1364/oe.11.000889 · Cited by 1,854
Self-citationMeasurement of intraocular distances by backscattering spectral interferometry
Fercher, A. F., Hitzenberger, C. K., Kamp, G., & El-Zaiat, S. Y. (1995) · Optics Communications · doi:10.1016/0030-4018(95)00119-s · Cited by 1,212
Huber, R., Wojtkowski, M., & Fujimoto, J. G. (2006) · Optics Express · doi:10.1364/oe.14.003225 · Cited by 982
State-of-the-art retinal optical coherence tomography
DREXLER, W., & FUJIMOTO, J. (2008) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2007.07.005 · Cited by 906
Speckle variance detection of microvasculature using swept-source optical coherence tomography
Mariampillai, A., Standish, B. A., Moriyama, E. H., Khurana, M., Munce, N. R., Leung, M. K. K., Jiang, J., Cable, A., Wilson, B. C., Vitkin, I. A., et al. (2008) · Optics Letters · doi:10.1364/ol.33.001530 · Cited by 699
Kur, J., Newman, E. A., & Chan-Ling, T. (2012) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2012.04.004 · Cited by 678
Regulation of retinal blood flow in health and disease
Pournaras, C. J., Rungger-Brändle, E., Riva, C. E., Hardarson, S. H., & Stefansson, E. (2008) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2008.02.002 · Cited by 618
Izatt, J. A., Kulkarni, M. D., Yazdanfar, S., Barton, J. K., & Welch, A. J. (1997) · Optics Letters · doi:10.1364/ol.22.001439 · Cited by 609
Makita, S., Hong, Y., Yamanari, M., Yatagai, T., & Yasuno, Y. (2006) · Optics Express · doi:10.1364/oe.14.007821 · Cited by 594
Cited by
A paradigm shift in imaging biomarkers in neovascular age-related macular degeneration
Schmidt-Erfurth, U., & Waldstein, S. M. (2016) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2015.07.007 · Cited by 390
Age-related macular degeneration and polypoidal choroidal vasculopathy in Asians
Wong, C. W., Yanagi, Y., Lee, W.-K., Ogura, Y., Yeo, I., Wong, T. Y., & Cheung, C. M. G. (2016) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2016.04.002 · Cited by 346
Review of Photoacoustic Flow Imaging: Its Current State and Its Promises
van den Berg, P. J., Daoudi, K., & Steenbergen, W. (2015) · Photoacoustics · doi:10.1016/j.pacs.2015.08.001 · Cited by 84
Metadata
- Authors
- Leitgeb, R. A., Werkmeister, R. M., Blatter, C., & Schmetterer, L.
- Venue
- Progress in Retinal and Eye Research
- Publisher
- Elsevier BV
- Published
- 2014-07
- Volume
- 41
- Pages
- 26-43
- ISSN
- 1350-9462 (ISSN-L)
- OpenAlex
- W2003531547
- Cited by
- 444
- References
- 61
- FWCI
- 23.51
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Doppler Optical Coherence Tomography. https://app.cochat.ai/papers/10.1016/j.preteyeres.2014.03.004
- The paper
- Leitgeb, R. A., Werkmeister, R. M., Blatter, C., & Schmetterer, L. (2014). Doppler Optical Coherence Tomography. Progress in Retinal and Eye Research. https://doi.org/10.1016/j.preteyeres.2014.03.004
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.