The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Agreement between spectral-domain and time-domain OCT for measuring RNFL thickness
Open accessAbstract
BACKGROUND/AIMS: To evaluate spectral-domain (SD) optical coherence tomography (OCT) reproducibility and assess the agreement between SD-OCT and Time-Domain (TD) OCT retinal nerve fibre layer (RNFL) measurements. METHODS: Three Cirrus-SD-OCT scans and one Stratus-TD-OCT scan were obtained from Diagnostic Innovations in Glaucoma Study (DIGS) healthy participants and glaucoma patients on the same day. Repeatability was evaluated using Sw (within-subject standard deviation), CV (coefficient of variation) and ICC (intraclass correlation coefficient). Agreement was assessed using correlation and Bland-Altman plots. RESULTS: 16 healthy participants (32 eyes) and 39 patients (78 eyes) were included. SD-OCT reproducibility was excellent in both groups. The CV and ICC for Average RNFL thickness were 1.5% and 0.96, respectively, in healthy eyes and 1.6% and 0.98, respectively, in patient eyes. Correlations between RNFL parameters were strong, particularly for average RNFL thickness (R(2) = 0.92 in patient eyes). Bland-Altman plots showed good agreement between instruments, with better agreement for average RNFL thickness than for sectoral RNFL parameters (for example, at 90 microm average RNFL thickness, 95% limits of agreement were -13.1 to 0.9 for healthy eyes and -16.2 to -0.3 microm for patient eyes). CONCLUSIONS: SD-OCT measurements were highly repeatable in healthy and patient eyes. Although the agreement between instruments was good, TD-OCT provided thicker RNFL measurements than SD-OCT. Measurements with these instruments should not be considered interchangeable.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1177/096228029900800204 · Cited by 9,619
Measuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1191/096228099673819272 · Cited by 9,619
Statistical Analysis of Correlated Data Using Generalized Estimating Equations: An Orientation
Hanley, J. A. (2003) · American Journal of Epidemiology · doi:10.1093/aje/kwf215 · Cited by 2,185
Cited by
Spectral-Domain OCT Measurements in Alzheimer’s Disease
Chan, V. T. T., Sun, Z., Tang, S., Chen, L. J., Wong, A., Tham, C. C., Wong, T. Y., Chen, C., Ikram, M. K., Whitson, H. E., et al. (2019) · Ophthalmology · doi:10.1016/j.ophtha.2018.08.009 · Cited by 360
Mwanza, J.-C., Chang, R. T., Budenz, D. L., Durbin, M. K., Gendy, M. G., Shi, W., & Feuer, W. J. (2010) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.10-5222 · Cited by 300
Linking structure and function in glaucoma
Harwerth, R. S., Wheat, J. L., Fredette, M. J., & Anderson, D. R. (2010) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2010.02.001 · Cited by 293
Lam, B. L., Feuer, W. J., Schiffman, J. C., Porciatti, V., Vandenbroucke, R., Rosa, P. R., Gregori, G., & Guy, J. (2014) · JAMA Ophthalmology · doi:10.1001/jamaophthalmol.2013.7971 · Cited by 96
Metadata
- Authors
- Vizzeri, G., Weinreb, R. N., Gonzalez-Garcia, A. O., Bowd, C., Medeiros, F. A., Sample, P. A., & Zangwill, L. M.
- Venue
- British Journal of Ophthalmology
- Publisher
- BMJ
- Published
- 2009-03-19
- Volume
- 93
- Issue
- 6
- Pages
- 775-781
- ISSN
- 0007-1161 (ISSN-L)
- OpenAlex
- W2032229012
- Cited by
- 192
- References
- 3
- FWCI
- 26.29
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.