CoChat

Corneal Endothelial Cell Damage from Glaucoma Drainage Device Materials

Lim, K. Sheng · 2003 · Cornea

The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.

Abstract

PURPOSE: To compare the level of endothelial damage caused by contact with materials used in contemporary glaucoma drainage devices and a phosphorylcholine polymer-coated PMMA (PC-PMMA). METHODS Standard-sized discs of silicone, PMMA (polymethylmethacrylate), and PC-PMMA (n = 6) were gently lowered onto cultured bovine corneal endothelial (BCE) monolayers using a vacuum suction device. A 2.4-g stainless steel cloning ring weight was then placed on top of each disc. The weights and discs were removed using a vacuum suction device and forceps after 5 minutes of contact. A 0.4% trypan blue solution was used to stain the cell monolayer to visualize the area of cell damage. The total area of damage in each well (including the area stripped of cells) was measured using an image processor and expressed as a percentage of the total disc area to derive a damage coefficient for each material. Damage coefficients for different materials were compared using Bonferroni corrected analysis of variance (ANOVA). RESULTS: Percentage of areas of damage (mean +/- SD) after standardized contact were as follows: PMMA, 5.95 +/- 4.60%; silicone, 3.08 +/- 2.68%; PC-PMMA, 0.15 +/- 0.25%. PMMA caused marked endothelial cell damage. PC-PMMA discs produced a significantly lower level (p = 0.04) of endothelial cell trauma. CONCLUSION: Our results suggest that PC coating technology may be effective in reducing the rate of corneal endothelial failure following GDD implantation.

Overview

Integrity signals

Registry

Crossref · 10.1097/00003226-200305000-00013

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Show all 12 references

Research works printed but not linked: 2

  1. Mateo, 1989, Invest Ophthalmol Vis Sci, 30, 853
  2. Hunter, 1993, Soc Thorac Surg, &NA;, 1329

Cited by

See all 35

Metadata

Authors
Lim, K. S.
Affiliations
Biocompatibles (United Kingdom) (GB)
Corresponding author
Lim, K. Sheng
Venue
Cornea
Published
2003-05
Volume
22
Issue
4
Pages
352-354
ISSN
0277-3740 (ISSN-L)
OpenAlex
W2160813618
Cited by
35
References
12
Citations by year
2026: 1 · 2025: 1 · 2023: 1 · 2022: 1 · 2021: 3 · 2020: 1 · 2019: 1 · 2018: 1 · 2017: 4 · 2016: 2 · 2015: 2 · 2014: 1 · 2013: 2 · 2012: 2
FWCI
1.06
Type
journal article
Language
en
Open access
closed
Locations
  • Cornea (publishedVersion)
  • PubMed (publishedVersion)
  • UCL Discovery (University College London) (submittedVersion)
  • University of Brighton Repository (University of Brighton) (submittedVersion)
Topics
  • Health Sciences › Medicine › Ophthalmology › Glaucoma and retinal disorders
  • Health Sciences › Medicine › Ophthalmology › Corneal surgery and disorders
  • Health Sciences › Medicine › Ophthalmology › Intraocular Surgery and Lenses
Keywords
glaucoma drainage devices, corneal endothelial cell damage, phosphorylcholine coating, PMMA, silicone, biocompatibility, endothelial monolayer, trypan blue staining
MeSH terms
Animals, Cattle, Cell Line, Drainage, Endothelium, Corneal, Glaucoma, Phosphorylcholine, Polymers, Silicones, Polymethyl Methacrylate, Coated Materials, Biocompatible

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Corneal Endothelial Cell Damage from Glaucoma Drainage Device Materials. https://app.cochat.ai/papers/10.1097/00003226-200305000-00013
The paper
Lim, K. S. (2003). Corneal Endothelial Cell Damage from Glaucoma Drainage Device Materials. Cornea. https://doi.org/10.1097/00003226-200305000-00013

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.