The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Automated identification of diabetic retinal exudates in digital colour images
Open accessAbstract
AIM: To identify retinal exudates automatically from colour retinal images. METHODS: The colour retinal images were segmented using fuzzy C-means clustering following some key preprocessing steps. To classify the segmented regions into exudates and non-exudates, an artificial neural network classifier was investigated. RESULTS: The proposed system can achieve a diagnostic accuracy with 95.0% sensitivity and 88.9% specificity for the identification of images containing any evidence of retinopathy, where the trade off between sensitivity and specificity was appropriately balanced for this particular problem. Furthermore, it demonstrates 93.0% sensitivity and 94.1% specificity in terms of exudate based classification. CONCLUSIONS: This study indicates that automated evaluation of digital retinal images could be used to screen for exudative diabetic retinopathy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Nature of Statistical Learning Theory
Vapnik, V. N. (1995) · doi:10.1007/978-1-4757-2440-0 · Cited by 39,138
Neural networks for pattern recognition
(1994) · Choice Reviews Online · doi:10.5860/choice.31-5500 · Cited by 18,538
A Tutorial on Support Vector Machines for Pattern Recognition
Burges, C. J. C. (1998) · Data Mining and Knowledge Discovery · doi:10.1023/a:1009715923555 · Cited by 16,429
An Introduction to Support Vector Machines and Other Kernel-based Learning Methods
Cristianini, N., & Shawe-Taylor, J. (2000) · doi:10.1017/cbo9780511801389 · Cited by 13,855
Neural Networks for Pattern Recognition
Bishop, C. M. (1995) · doi:10.1093/oso/9780198538493.001.0001 · Cited by 12,287
Pattern Recognition with Fuzzy Objective Function Algorithms
Bezdek, J. C. (1981) · doi:10.1007/978-1-4757-0450-1 · Cited by 9,881
Algorithms for Clustering Data
Sarle, W. S. (1990) · Technometrics · doi:10.1080/00401706.1990.10484648 · Cited by 7,865
Fundamentals of digital image processing
Jain, A. K. (1988) · Cited by 7,111
Hanley, J. A., & McNeil, B. J. (1983) · Radiology · doi:10.1148/radiology.148.3.6878708 · Cited by 7,016
Statistical pattern recognition: a review
Jain, A. K., Duin, P. W., & Mao, J. (2000) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.824819 · Cited by 6,767
Cited by
Retinal Imaging and Image Analysis
Abramoff, M. D., Garvin, M. K., & Sonka, M. (2010) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2010.2084567 · Cited by 1,439
Aquino, A., Gegúndez-Arias, M. E., & Marín, D. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2053042 · Cited by 516
Sopharak, A., Uyyanonvara, B., Barman, S., & Williamson, T. H. (2008) · Computerized Medical Imaging and Graphics · doi:10.1016/j.compmedimag.2008.08.009 · Cited by 405
Niemeijer, M., van Ginneken, B., Russell, S. R., Suttorp-Schulten, M. S. A., & Abra`moff, M. D. (2007) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.06-0996 · Cited by 400
Exudate-based diabetic macular edema detection in fundus images using publicly available datasets
Giancardo, L., Meriaudeau, F., Karnowski, T. P., Li, Y., Garg, S., Tobin, K. W., & Chaum, E. (2012) · Medical Image Analysis · doi:10.1016/j.media.2011.07.004 · Cited by 322
Metadata
- Authors
- Osareh, A.
- Venue
- British Journal of Ophthalmology
- Publisher
- BMJ
- Published
- 2003-10-01
- Volume
- 87
- Issue
- 10
- Pages
- 1220-1223
- ISSN
- 0007-1161 (ISSN-L)
- OpenAlex
- W2095006131
- Cited by
- 254
- References
- 27
- FWCI
- 3.10
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Automated identification of diabetic retinal exudates in digital colour images. https://app.cochat.ai/papers/10.1136/bjo.87.10.1220
- The paper
- Osareh, A. (2003). Automated identification of diabetic retinal exudates in digital colour images. British Journal of Ophthalmology. https://doi.org/10.1136/bjo.87.10.1220
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.