BACKGROUND/AIMS: Retinal screening programmes in England and Scotland have similar photographic grading schemes for background (non-proliferative) and proliferative diabetic retinopathy, but diverge over maculopathy. We looked for the most cost-effective method of identifying diabetic macular oedema from retinal photographs including the role of automated grading and optical coherence tomography, a technology that directly visualises oedema. METHODS: Patients from seven UK centres were recruited. The following features in at least one eye were required for enrolment: microaneurysms/dot haemorrhages or blot haemorrhages within one disc diameter, or exudates within one or two disc diameters of the centre of the macula. Subjects had optical coherence tomography and digital photography. Manual and automated grading schemes were evaluated. Costs and QALYs were modelled using microsimulation techniques. RESULTS: 3540 patients were recruited, 3170 were analysed. For diabetic macular oedema, England's scheme had a sensitivity of 72.6% and specificity of 66.8%; Scotland's had a sensitivity of 59.5% and specificity of 79.0%. When applying a ceiling ratio of £30,000 per quality adjusted life years (QALY) gained, Scotland's scheme was preferred. Assuming automated grading could be implemented without increasing grading costs, automation produced a greater number of QALYS for a lower cost than England's scheme, but was not cost effective, at the study's operating point, compared with Scotland's. The addition of optical coherence tomography, to each scheme, resulted in cost savings without reducing health benefits. CONCLUSIONS: Retinal screening programmes in the UK should reconsider the screening pathway to make best use of existing and new technologies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Decision Modelling For Health Economic Evaluation
Briggs, A., Claxton, K., & Sculpher, M. (2006) · doi:10.1093/oso/9780198526629.001.0001 · Cited by 3,153
Soedamah-Muthu, S. S., Fuller, J. H., Mulnier, H. E., Raleigh, V. S., Lawrenson, R. A., & Colhoun, H. M. (2006) · Diabetologia · doi:10.1007/s00125-005-0120-4 · Cited by 240
Cited by
Tan, G. S., Cheung, N., Simó, R., Cheung, G. C. M., & Wong, T. Y. (2017) · The Lancet Diabetes & Endocrinology · doi:10.1016/s2213-8587(16)30052-3 · Cited by 361
Retinal Imaging Techniques for Diabetic Retinopathy Screening
Goh, J. K. H., Cheung, C. Y., Sim, S. S., Tan, P. C., Tan, G. S. W., & Wong, T. Y. (2016) · Journal of Diabetes Science and Technology · doi:10.1177/1932296816629491 · Cited by 174
Xie, Y., Gunasekeran, D. V., Balaskas, K., Keane, P. A., Sim, D. A., Bachmann, L. M., Macrae, C., & Ting, D. S. W. (2020) · Translational Vision Science & Technology · doi:10.1167/tvst.9.2.22 · Cited by 59
Saving sight in China and beyond: the Lifeline Express model
Wong, I. Y. H., Ni, M. Y., Wong, I. O. L., Fong, N., & Leung, G. M. (2018) · BMJ Global Health · doi:10.1136/bmjgh-2018-000766 · Cited by 19
Leigh, J., Drinkwater, J., Turner, A., & Schroeder, E. (2026) · Clinical & Experimental Ophthalmology · doi:10.1111/ceo.70016 · Cited by 8
“Four studies were conducted in the United States [19, 30, 31, 33], four in the United Kingdom (including two in Scotland) [34, 35, 37, 38], and one each in Australia [22], Brazil [27], Norway [20], Singapore [32], and Thailand [24].”
Influential
Metadata
- Authors
- Prescott, G., Sharp, P., Goatman, K., Scotland, G., Fleming, A., Philip, S., Staff, R., Santiago, C., Borooah, S., Broadbent, D., Chong, V., Dodson, P., Harding, S., Leese, G., Megaw, R., Styles, C., Swa, K., Wharton, H., & Olson, J.
- Venue
- British Journal of Ophthalmology
- Publisher
- BMJ
- Published
- 2014-03-28
- Volume
- 98
- Issue
- 8
- Pages
- 1042-1049
- ISSN
- 0007-1161 (ISSN-L)
- 1468-2079
- OpenAlex
- W2016703187
- Cited by
- 55
- References
- 2
- FWCI
- 3.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Improving the cost-effectiveness of photographic screening for diabetic macular oedema: a prospective, multi-centre, UK study. https://app.cochat.ai/papers/10.1136/bjophthalmol-2013-304338
- The paper
- Prescott, G., Sharp, P., Goatman, K., Scotland, G., Fleming, A., Philip, S., Staff, R., Santiago, C., Borooah, S., Broadbent, D., Chong, V., Dodson, P., Harding, S., Leese, G., Megaw, R., Styles, C., Swa, K., Wharton, H., & Olson, J. (2014). Improving the cost-effectiveness of photographic screening for diabetic macular oedema: a prospective, multi-centre, UK study. British Journal of Ophthalmology. https://doi.org/10.1136/bjophthalmol-2013-304338
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).