Evaluation of a hub-and-spoke model for the delivery of femtosecond laser-assisted cataract surgery within the context of a large randomised controlled trial
Open accessThe DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
Aims: To test a hypothesis that cataract operating room (OR) productivity can be improved with a femtosecond laser (FL) using a hub-and-spoke model and whether any increase in productivity can offset additional costs relating to the FL. Methods: 400 eyes of 400 patients were enrolled in a randomised-controlled trial comparing FL-assisted cataract surgery (FLACS) with conventional phacoemulsification surgery (CPS). 299 of 400 operations were performed on designated high-volume theatre lists (FLACS=134, CPS=165), where a hub-and-spoke FLACS model (1×FL, 2×ORs=2:1) was compared with independent CPS theatre lists. Details of operative timings and OR utilisation were recorded. Differences in productivity between hub-and-spoke FLACS and CPS sessions were compared using an economic model including testing hypothetical 3:1 and 4:1 models. Results: The duration of the operation itself was 12.04±4.89 min for FLACS compared with CPS of 14.54±6.1 min (P<0.001). Total patient time in the OR was reduced from 23.39±6.89 min with CPS to 20.34±5.82 min with FLACS (P<0.001)(reduction of 3.05 min per case). There was no difference in OR turnaround time between the models. Average number of patients treated per theatre list was 9 for FLACS and 8 for CPS. OR utilisation was 92.08% for FLACS and 95.83% for CPS (P<0.001). Using a previously established economic model, the FLACS service cost £144.60 more than CPS per case. This difference would be £131 and £125 for 3:1 and 4:1 models, respectively. Conclusion: The FLACS hub-and-spoke model was significantly faster than CPS, with patients spending less time in the OR. This enabled an improvement in productivity, but insufficient to meaningfully offset the additional costs relating to FLACS.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The text we found for this paper looks like another document, so the self-check wasn’t run.
Citations
Cites
Initial Clinical Evaluation of an Intraocular Femtosecond Laser in Cataract Surgery
Nagy, Z., Takacs, A., Filkorn, T., & Sarayba, M. (2009) · Journal of Refractive Surgery · doi:10.3928/1081597x-20091117-04 · Cited by 563
Narendran, N., Jaycock, P., Johnston, R. L., Taylor, H., Adams, M., Tole, D. M., Asaria, R. H., Galloway, P., & Sparrow, J. M. (2009) · Eye · doi:10.1038/sj.eye.6703049 · Cited by 308
Surgical Outcomes and Safety of Femtosecond Laser Cataract Surgery
Roberts, T. V., Lawless, M., Bali, S. J., Hodge, C., & Sutton, G. (2013) · Ophthalmology · doi:10.1016/j.ophtha.2012.10.026 · Cited by 230
Early Experience with the Femtosecond Laser for Cataract Surgery
Bali, S. J., Hodge, C., Lawless, M., Roberts, T. V., & Sutton, G. (2012) · Ophthalmology · doi:10.1016/j.ophtha.2011.12.025 · Cited by 214
Laser-assisted cataract surgery versus standard ultrasound phacoemulsification cataract surgery
Day, A. C., Gore, D. M., Bunce, C., & Evans, J. R. (2016) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd010735.pub2 · Cited by 167
Abell, R. G., Darian-Smith, E., Kan, J. B., Allen, P. L., Ewe, S. Y. P., & Vote, B. J. (2015) · Journal of Cataract and Refractive Surgery · doi:10.1016/j.jcrs.2014.06.025 · Cited by 160
Femtosecond laser‐assisted cataract surgery compared with conventional cataract surgery
Abell, R. G., Kerr, N. M., & Vote, B. J. T. (2012) · Clinical and Experimental Ophthalmology · doi:10.1111/ceo.12025 · Cited by 145
Abell, R. G., & Vote, B. J. T. (2013) · Ophthalmology · doi:10.1016/j.ophtha.2013.07.056 · Cited by 133
Changes in Prostaglandin Levels in Patients Undergoing Femtosecond Laser-Assisted Cataract Surgery
Schultz, T., Joachim, S. C., Kuehn, M., & Dick, H. B. (2013) · Journal of Refractive Surgery · doi:10.3928/1081597x-20131021-03 · Cited by 122
Conrad-Hengerer, I., Sheikh, M. A., Hengerer, F. H., Schultz, T., & Dick, H. B. (2015) · Journal of Cataract & Refractive Surgery · doi:10.1016/j.jcrs.2014.10.044 · Cited by 92
Cited by
Roberts, H. W., Wagh, V. K., Sullivan, D. L., Hidzheva, P., Detesan, D. I., Heemraz, B. S., Sparrow, J. M., & O'Brart, D. P. S. (2018) · Journal of Cataract & Refractive Surgery · doi:10.1016/j.jcrs.2018.08.033 · Cited by 79
Self-citationFemtosecond laser–assisted cataract surgery: A review
Roberts, H. W., Day, A. C., & O'Brart, D. P. S. (2019) · European Journal of Ophthalmology · doi:10.1177/1120672119893291 · Cited by 77
Self-citationLaser-assisted cataract surgery versus standard ultrasound phacoemulsification cataract surgery
Narayan, A. R., Evans, J. R., O'Brart, D. P. S., Bunce, C., Gore, D. M., & Day, A. C. (2023) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd010735.pub3 · Cited by 77
Self-citationHow Ophthalmologists Can Decarbonize Eye Care
Sherry, B., Lee, S., Ramos Cadena, M. D. L. A., Laynor, G., Patel, S. R., Simon, M. D., Romanowski, E. G., Hochman, S. E., Schuman, J. S., Prescott, C., et al. (2023) · Ophthalmology · doi:10.1016/j.ophtha.2023.02.028 · Cited by 47
Carbon Emissions from Overuse of U.S. Health Care: Medical and Ethical Problems
Thiel, C. L., & Richie, C. (2022) · The Hastings Center Report · doi:10.1002/hast.1404 · Cited by 47
Shaking the usability tree: why usability is not a dead end, and a constructive way forward
Borsci, S., Federici, S., Malizia, A., & Filippis, M. L. D. (2018) · Behaviour and Information Technology · doi:10.1080/0144929x.2018.1541255 · Cited by 45
“…usability methods in healthcare are one of the multiple evidence needed to assess services and tools, and to support the adoption of new systems and processes (Green and Mercer 2001; Brown et al. 2013; Federici, Meloni, and Borsci 2016; Borsci et al. 2017; Roberts et al. 2017; Roberts et al. 2018).”
BackgroundSelf-citationFemtosecond Laser Assisted Cataract Surgery: A Review
Agarwal, K. K., & Hatch, K. M. (2021) · Seminars in Ophthalmology · doi:10.1080/08820538.2021.1890792 · Cited by 43
The future of cataract surgery
O'Brart, D. P. S. (2025) · Eye · doi:10.1038/s41433-025-03745-x · Cited by 36
“Compared to PCS, outcomes are similar [62] and we demonstrated that even with models to improve productivity extra FLACS-associated costs cannot be offset [63].”
Self-citationO'Brart, D. P. S., Roberts, H. W., Naderi, K., & Gormley, J. (2020) · BMJ Open Ophthalmology · doi:10.1136/bmjophth-2019-000426 · Cited by 29
Self-citationXu, J., Chen, X., Wang, H., & Yao, K. (2022) · Advances in Ophthalmology Practice and Research · doi:10.1016/j.aopr.2022.100027 · Cited by 25
“Fifteen studies, 14,21,23,28,30 – 32, 34, 35,42,”
Portney, D. S., Berkowitz, S. T., Garner, D. C., Qalieh, A., Tiwari, V., Friedman, S. M., Patel, S. N., Parikh, R., & Mian, S. I. (2023) · JAMA Ophthalmology · doi:10.1001/jamaophthalmol.2023.0091 · Cited by 24
Stanojcic, N., Roberts, H. W., Wagh, V. K., Li, J.-P. O., Naderi, K., & O'Brart, D. P. S. (2020) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2020-316311 · Cited by 24
Self-citationCalabrò, R. S., Manuli, A., Cola, M. C. D., & Bramanti, P. (2020) · Journal of Health Organization and Management · doi:10.1108/jhom-07-2019-0200 · Cited by 18
Léda, R. M., Machado, D. C. S., Hida, W. T., Motta, A. F. P., Pacini, T. D. F., & de Amorim, R. F. B. (2023) · Clinical ophthalmology · doi:10.2147/opth.s408717 · Cited by 17
“60 more than conventional surgery per case.(8,10,11) This study aimed to analyze whether the use of FLACS results in lower CDE and less loss of corneal endothelial cells than those associated with the conventional method, especially in cases of grade 2 or grade 3 cataracts that are not associated with other ocular com…”
BackgroundAzuara‐Blanco, A., Carlisle, A., O’Donnell, M., Jayaram, H., Gazzard, G., Larkin, F., Wickham, L., & Lois, N. (2022) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2022.12.010 · Cited by 15
Song, X., Li, L., Zhang, X., & Ma, J. (2024) · Canadian Journal of Ophthalmology · doi:10.1016/j.jcjo.2024.05.030 · Cited by 12
Akbari‐Moghaddam, M., Li, N., Down, D. G., Arnold, D. M., Callum, J., Bégin, P., & Heddle, N. M. (2023) · INFOR Information Systems and Operational Research · doi:10.1080/03155986.2023.2264985 · Cited by 10
“…who are currently infected with COVID-19 and require CCP, but will be considered as supply once they recover and donate CCP. Hub-and-spoke structures can help effective access to blood products in a public health network and clinical trials (Roberts et al. 2018; Fernandez-Sojo et al. 2023).”
BackgroundSalgado, R. M. P. C., Torres, P. F. A. A. S., & Marinho, A. (2023) · Clinical ophthalmology · doi:10.2147/opth.s399788 · Cited by 7
Moshirfar, M., Waite, A. J., Ellis, J. H., Huynh, R., Placide, J., Barke, M. R., McCabe, S. E., Ronquillo, Y. C., Hoopes, P. C., Bradley, M. J., et al. (2021) · Clinical ophthalmology · doi:10.2147/opth.s336356 · Cited by 6
“This finding is consistent with previous studies that found reduced operation duration for FLACS compared to PCS.(22,23) We must note that in our clinical practice, the total time for cataract surgery is higher in the FLACS group, consistent with previous studies.”
ResultInfluentialVillavilla-Castillo, J., Pérez-Casaseca, C., Espejo-de-los-Riscos, E., Vaca, G. F.-B., Fernández-Baca-Casares, I., Pinero, D. P., Rocha‐de‐Lossada, C., & Rodríguez‐Calvo‐de‐Mora, M. (2021) · Journal Français d Ophtalmologie · doi:10.1016/j.jfo.2021.01.030 · Cited by 4
The Use of Decision Analytic Modeling in the Evaluation of Surgical Innovations: A Scoping Review
Scholte, M., Rovers, M. M., & Grutters, J. P. C. (2021) · Value in Health · doi:10.1016/j.jval.2020.11.020 · Cited by 4
Human factors and system thinking for medical device
Borsci, S., & David, L. Z. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-813467-2.00118-8 · Cited by 3
Self-citationAdvances in cataract surgery: is a new era on the horizon?
Zhang, X., Yu, Y., & Yao, K. (2026) · Current Opinion in Ophthalmology · doi:10.1097/icu.0000000000001219 · Cited by 2
O uso do laser de femtosegundo na cirurgia da catarata assistida
Branco, F. R. E., & Moreira, H. (2024) · BioSCIENCE · doi:10.55684/2024.82.e037 · Cited by 2
Salgado, R. M. P. C., Torres, P. F. A. A. S., & Marinho, A. A. P. (2021) · The Open Ophthalmology Journal · doi:10.2174/1874364102115010043 · Cited by 2
Léda, R. M. (2023) · RIUnB Institutional Repository (University of Brasília) · Cited by 1
Anterior Capsulotomy Innovations and Techniques: Review
Ferguson, T. J., & Wiley, W. F. (2019) · Current Ophthalmology Reports · doi:10.1007/s40135-019-00219-8
Recent Updates in Femtosecond Laser-assisted Cataract Surgery
Portney, D. S., Thibodeau, A., & Mian, S. I. (2020) · International Ophthalmology Clinics · doi:10.1097/iio.0000000000000338
Léda, R. M., Machado, D. C. S., Hida, W. T., Motta, A. F. P., Pacini, T. D. F., & Amorim, R. F. (2023) · Dove Medical Press (Taylor and Francis Group)
Optimizing Cataract Surgery Workflows Across a Multi-Satellite Tertiary Care Center
Ashry, A. E., Ashry, M. E., Kang, S., Palioura, S., Gibbons, A. G., Correa, J. M. M., Ansari, Z., Theotoka, D., Yoo, S. H., Biekman, T. R., et al. (2026) · Clinical ophthalmology · doi:10.2147/opth.s631136
“29,30 31–33”
Metadata
- Authors
- Roberts, H. W., Wagh, V. K., Mullens, I. J. M., Borsci, S., Ni, M. Z., & O’Brart, D. P. S.
- Affiliations
- St Thomas' Hospital (GB)
- Imperial College London (GB)
- Corresponding author
- Roberts, Harry W
- Venue
- British Journal of Ophthalmology
- Publisher
- BMJ
- Published
- 2018-02-07
- Volume
- 102
- Issue
- 11
- Pages
- 1556-1563
- ISSN
- 0007-1161 (ISSN-L)
- 1468-2079
- OpenAlex
- W2787635812
- Cited by
- 26
- References
- 21
- Citations by year
- 2026: 1 · 2025: 1 · 2024: 1 · 2023: 6 · 2022: 3 · 2021: 5 · 2020: 4 · 2019: 3 · 2018: 2
- FWCI
- 5.36
- Type
- journal article
- Language
- en
- Open access
- green
- research.utwente.nl
- Licence
- other-oa
- Locations
- British Journal of Ophthalmology (publishedVersion)
- PubMed (publishedVersion)
- University of Twente Research Information (publishedVersion, other-oa)
- HighWire Press Open Archive (submittedVersion)
- Spiral (Imperial College London) (submittedVersion)
- University of Twente Research Information (submittedVersion, other-oa)
- Funders
- Alcon
- Topics
- Social Sciences › Decision Sciences › Management Science and Operations Research › Healthcare Operations and Scheduling Optimization
- Health Sciences › Medicine › Ophthalmology › Intraocular Surgery and Lenses
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Healthcare Quality and Management
- Keywords
- femtosecond laser-assisted cataract surgery, hub and spoke model, operating room productivity, phacoemulsification, surgical costs, operative time, cataract surgery
- MeSH terms
- Aged, Aged, 80 and over, Cataract Extraction, Female, Humans, Male, Middle Aged, Operating Rooms, Prospective Studies, Visual Acuity, Models, Organizational, Efficiency, Organizational, Models, Economic, Phacoemulsification, Pseudophakia, Lens Implantation, Intraocular, Laser Therapy, Operative Time
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.