The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Initial Clinical Evaluation of an Intraocular Femtosecond Laser in Cataract Surgery
Abstract
Purpose: To evaluate femtosecond laser lens fragmentation and anterior capsulotomy in cataract surgery. Methods: Anterior capsulotomy and phacofragmentation procedures performed with an intraocular femtosecond laser (LenSx Lasers Inc) were initially evaluated in ex vivo porcine eyes. These procedures were then performed in an initial series of nine patients undergoing cataract surgery. In addition to standard intraoperative assessments (including capsulotomy diameter accuracy and reproducibility), optical coherence tomography was used to evaluate human procedures. Results: For an intended 5-mm capsulorrhexis in porcine eyes, average achieved diameters were 5.88±0.73 mm using a standard manual technique and 5.02±0.04 mm using the femtosecond laser. Scanning electron microscopy revealed equally smooth cut edges of the capsulotomy with the femtosecond laser and manual technique. Compared to control porcine eyes, femtosecond laser phacofragmentation resulted in a 43% reduction in phacoemulsification power and a 51% decrease in phacoemulsification time. In a small series of human clinical procedures, femtosecond laser capsulotomies and phacofragmentation demonstrated similarly high levels of accuracy and effectiveness, with no operative complications. Conclusions: Initial results with an intraocular femtosecond laser demonstrate higher precision of capsulorrhexis and reduced phacoemulsification power in porcine and human eyes. [ J Refract Surg . 2009;25:1053–1060.]
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sources of error in intraocular lens power calculation
Norrby, S. (2008) · Journal of Cataract & Refractive Surgery · doi:10.1016/j.jcrs.2007.10.031 · Cited by 708
Juhasz, T., Kastis, G. A., Suárez, C., Bor, Z., & Bron, W. E. (1996) · Lasers in Surgery and Medicine · doi:10.1002/(sici)1096-9101(1996)19:1<23::aid-lsm4>3.0.co;2-s · Cited by 204
Vogel, A., Schweiger, P., Frieser, A., Asiyo, M. N., & Birngruber, R. (1990) · IEEE Journal of Quantum Electronics · doi:10.1109/3.64361 · Cited by 188
Time-resolved measurements of picosecond optical breakdown
Zysset, B., Fujimoto, J. G., & Deutsch, T. F. (1989) · Applied Physics B · doi:10.1007/bf00692139 · Cited by 115
Photodisruption in the Human Cornea as a Function of Laser Pulse Width
Kurtz, R. M., Liu, X., Elner, V. M., et al. (1997) · Journal of Refractive Surgery · doi:10.3928/1081-597x-19971101-12 · Cited by 101
Thresholds for visible lesions in the primate eye produced by ultrashort near-infrared laser pulses.
Cain, C. P., Toth, C. A., Noojin, G. D., Carothers, V., Stolarski, D. J., & Rockwell, B. A. (1999) · PubMed · Cited by 34
Cited by
Friedman, N. J., Palanker, D. V., Schuele, G., Andersen, D., Marcellino, G., Seibel, B. S., Batlle, J., Feliz, R., Talamo, J. H., Blumenkranz, M. S., et al. (2011) · Journal of Cataract and Refractive Surgery · doi:10.1016/j.jcrs.2011.04.022 · Cited by 373
Cicinelli, M. V., Buchan, J. C., Nicholson, M., Varadaraj, V., & Khanna, R. C. (2023) · The Lancet · doi:10.1016/s0140-6736(22)01839-6 · Cited by 332
Cataract in the Adult Eye Preferred Practice Pattern®
Olson, R. J., Braga-Mele, R., Chen, S. H., Miller, K. M., Pineda, R., Tweeten, J. P., & Musch, D. C. (2017) · Ophthalmology · doi:10.1016/j.ophtha.2016.09.027 · Cited by 277
Comparison of Intraocular Lens Decentration Parameters After Femtosecond and Manual Capsulotomies
Nagy, Z. Z., Kránitz, K., Takacs, A. I., Miháltz, K., Kovács, I., & Knorz, M. C. (2011) · Journal of Refractive Surgery · doi:10.3928/1081597x-20110607-01 · Cited by 268
Self-citationRoberts, H. W., Wagh, V. K., Mullens, I. J. M., Borsci, S., Ni, M. Z., & O’Brart, D. P. S. (2018) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2017-311319 · Cited by 26
Metadata
- Authors
- Nagy, Z., Takacs, A., Filkorn, T., & Sarayba, M.
- Venue
- Journal of Refractive Surgery
- Publisher
- SLACK, Inc.
- Published
- 2009-12
- Volume
- 25
- Issue
- 12
- Pages
- 1053-1060
- ISSN
- 1042-962X (ISSN-L)
- 1081-597X
- OpenAlex
- W2051165601
- Cited by
- 563
- References
- 6
- FWCI
- 23.44
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Initial Clinical Evaluation of an Intraocular Femtosecond Laser in Cataract Surgery. https://app.cochat.ai/papers/10.3928/1081597x-20091117-04
- The paper
- Nagy, Z., Takacs, A., Filkorn, T., & Sarayba, M. (2009). Initial Clinical Evaluation of an Intraocular Femtosecond Laser in Cataract Surgery. Journal of Refractive Surgery. https://doi.org/10.3928/1081597x-20091117-04
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.