Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 563

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Initial Clinical Evaluation of an Intraocular Femtosecond Laser in Cataract Surgery

Nagy, Zoltan, Takacs, Agnes, Filkorn, Tamas, Sarayba, Melvin·2009·Journal of Refractive Surgery

Abstract

Purpose: To evaluate femtosecond laser lens fragmentation and anterior capsulotomy in cataract surgery. Methods: Anterior capsulotomy and phacofragmentation procedures performed with an intraocular femtosecond laser (LenSx Lasers Inc) were initially evaluated in ex vivo porcine eyes. These procedures were then performed in an initial series of nine patients undergoing cataract surgery. In addition to standard intraoperative assessments (including capsulotomy diameter accuracy and reproducibility), optical coherence tomography was used to evaluate human procedures. Results: For an intended 5-mm capsulorrhexis in porcine eyes, average achieved diameters were 5.88±0.73 mm using a standard manual technique and 5.02±0.04 mm using the femtosecond laser. Scanning electron microscopy revealed equally smooth cut edges of the capsulotomy with the femtosecond laser and manual technique. Compared to control porcine eyes, femtosecond laser phacofragmentation resulted in a 43% reduction in phacoemulsification power and a 51% decrease in phacoemulsification time. In a small series of human clinical procedures, femtosecond laser capsulotomies and phacofragmentation demonstrated similarly high levels of accuracy and effectiveness, with no operative complications. Conclusions: Initial results with an intraocular femtosecond laser demonstrate higher precision of capsulorrhexis and reduced phacoemulsification power in porcine and human eyes. [ J Refract Surg . 2009;25:1053–1060.]

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.3928/1081597x-20091117-04

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 563

Metadata

Authors
Nagy, Z., Takacs, A., Filkorn, T., & Sarayba, M.
Venue
Journal of Refractive Surgery
Publisher
SLACK, Inc.
Published
2009-12
Volume
25
Issue
12
Pages
1053-1060
ISSN
  • 1042-962X (ISSN-L)
  • 1081-597X
OpenAlex
W2051165601
Cited by
563
References
6
FWCI
23.44
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Initial Clinical Evaluation of an Intraocular Femtosecond Laser in Cataract Surgery. https://app.cochat.ai/papers/10.3928/1081597x-20091117-04
The paper
Nagy, Z., Takacs, A., Filkorn, T., & Sarayba, M. (2009). Initial Clinical Evaluation of an Intraocular Femtosecond Laser in Cataract Surgery. Journal of Refractive Surgery. https://doi.org/10.3928/1081597x-20091117-04

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.