Evaluation of a hub-and-spoke model for the delivery of femtosecond laser-assisted cataract surgery within the context of a large randomised controlled trial
Open accessThe DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
Aims: To test a hypothesis that cataract operating room (OR) productivity can be improved with a femtosecond laser (FL) using a hub-and-spoke model and whether any increase in productivity can offset additional costs relating to the FL. Methods: 400 eyes of 400 patients were enrolled in a randomised-controlled trial comparing FL-assisted cataract surgery (FLACS) with conventional phacoemulsification surgery (CPS). 299 of 400 operations were performed on designated high-volume theatre lists (FLACS=134, CPS=165), where a hub-and-spoke FLACS model (1×FL, 2×ORs=2:1) was compared with independent CPS theatre lists. Details of operative timings and OR utilisation were recorded. Differences in productivity between hub-and-spoke FLACS and CPS sessions were compared using an economic model including testing hypothetical 3:1 and 4:1 models. Results: The duration of the operation itself was 12.04±4.89 min for FLACS compared with CPS of 14.54±6.1 min (P<0.001). Total patient time in the OR was reduced from 23.39±6.89 min with CPS to 20.34±5.82 min with FLACS (P<0.001)(reduction of 3.05 min per case). There was no difference in OR turnaround time between the models. Average number of patients treated per theatre list was 9 for FLACS and 8 for CPS. OR utilisation was 92.08% for FLACS and 95.83% for CPS (P<0.001). Using a previously established economic model, the FLACS service cost £144.60 more than CPS per case. This difference would be £131 and £125 for 3:1 and 4:1 models, respectively. Conclusion: The FLACS hub-and-spoke model was significantly faster than CPS, with patients spending less time in the OR. This enabled an improvement in productivity, but insufficient to meaningfully offset the additional costs relating to FLACS.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The text we found for this paper looks like another document, so the self-check wasn’t run.
Citations
Cites
Initial Clinical Evaluation of an Intraocular Femtosecond Laser in Cataract Surgery
Nagy, Z., Takacs, A., Filkorn, T., & Sarayba, M. (2009) · Journal of Refractive Surgery · doi:10.3928/1081597x-20091117-04 · Cited by 563
Narendran, N., Jaycock, P., Johnston, R. L., Taylor, H., Adams, M., Tole, D. M., Asaria, R. H., Galloway, P., & Sparrow, J. M. (2009) · Eye · doi:10.1038/sj.eye.6703049 · Cited by 308
Surgical Outcomes and Safety of Femtosecond Laser Cataract Surgery
Roberts, T. V., Lawless, M., Bali, S. J., Hodge, C., & Sutton, G. (2013) · Ophthalmology · doi:10.1016/j.ophtha.2012.10.026 · Cited by 230
Early Experience with the Femtosecond Laser for Cataract Surgery
Bali, S. J., Hodge, C., Lawless, M., Roberts, T. V., & Sutton, G. (2012) · Ophthalmology · doi:10.1016/j.ophtha.2011.12.025 · Cited by 214
Laser-assisted cataract surgery versus standard ultrasound phacoemulsification cataract surgery
Day, A. C., Gore, D. M., Bunce, C., & Evans, J. R. (2016) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd010735.pub2 · Cited by 167
Abell, R. G., Darian-Smith, E., Kan, J. B., Allen, P. L., Ewe, S. Y. P., & Vote, B. J. (2015) · Journal of Cataract and Refractive Surgery · doi:10.1016/j.jcrs.2014.06.025 · Cited by 160
Femtosecond laser‐assisted cataract surgery compared with conventional cataract surgery
Abell, R. G., Kerr, N. M., & Vote, B. J. T. (2012) · Clinical and Experimental Ophthalmology · doi:10.1111/ceo.12025 · Cited by 145
Abell, R. G., & Vote, B. J. T. (2013) · Ophthalmology · doi:10.1016/j.ophtha.2013.07.056 · Cited by 133
Changes in Prostaglandin Levels in Patients Undergoing Femtosecond Laser-Assisted Cataract Surgery
Schultz, T., Joachim, S. C., Kuehn, M., & Dick, H. B. (2013) · Journal of Refractive Surgery · doi:10.3928/1081597x-20131021-03 · Cited by 122
Conrad-Hengerer, I., Sheikh, M. A., Hengerer, F. H., Schultz, T., & Dick, H. B. (2015) · Journal of Cataract & Refractive Surgery · doi:10.1016/j.jcrs.2014.10.044 · Cited by 92
Initial evaluation of a femtosecond laser system in cataract surgery
Chang, J. S. M., Chen, I. N., Chan, W., Ng, J. C. M., Chan, V. K. C., & Law, A. K. P. (2013) · Journal of Cataract & Refractive Surgery · doi:10.1016/j.jcrs.2013.08.045 · Cited by 92
Ewe, S. Y. P., Abell, R. G., Oakley, C. L., Lim, C. H. L., Allen, P. L., McPherson, Z. E., Rao, A. V., Davies, P. E. J., & Vote, B. J. T. (2015) · Ophthalmology · doi:10.1016/j.ophtha.2015.09.026 · Cited by 70
Clinical Outcomes in the First Two Years of Femtosecond Laser–Assisted Cataract Surgery
Chee, S.-P., Yang, Y., & Ti, S. (2015) · American Journal of Ophthalmology · doi:10.1016/j.ajo.2015.01.016 · Cited by 64
Wang, L., Zhang, Z., Koch, D. D., Jia, Y., Cao, W., & Zhang, S. (2015) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2015-307586 · Cited by 49
Lubahn, J. G., Donaldson, K. E., Culbertson, W. W., & Yoo, S. H. (2014) · Journal of Cataract & Refractive Surgery · doi:10.1016/j.jcrs.2014.03.024 · Cited by 43
Rego, A. S. D. M. (2019) · Biomedical Journal of Scientific & Technical Research · doi:10.26717/bjstr.2019.20.003407 · Cited by 30
Roberts, H. W., Ni, M. Z., & O'Brart, D. P. S. (2017) · BMJ Open · doi:10.1136/bmjopen-2016-013616 · Cited by 29
Self-citationThe economic cost of posterior capsule tear at cataract surgery
Qatarneh, D., Mathew, R. G., Palmer, S., Bunce, C., & Tuft, S. J. (2011) · British Journal of Ophthalmology · doi:10.1136/bjo.2010.200832 · Cited by 23
Roberts, H. W., Myerscough, J., Borsci, S., Ni, M. Z., & O'Brart, D. P. S. (2017) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2017-310452 · Cited by 17
Self-citationDay, A. C., Dhallu, S. K., Maurino, V., & Wilkins, M. R. (2016) · BMJ Open · doi:10.1136/bmjopen-2016-012078 · Cited by 16
Outcomes of femtosecond laser-assisted cataract surgery performed by surgeons-in-training
Brunin, G., Khan, K., Biggerstaff, K., Wang, L., Koch, D. D., & Khandelwal, S. S. (2017) · Graefe s Archive for Clinical and Experimental Ophthalmology · doi:10.1007/s00417-016-3581-x · Cited by 14
Cited by
Roberts, H. W., Wagh, V. K., Sullivan, D. L., Hidzheva, P., Detesan, D. I., Heemraz, B. S., Sparrow, J. M., & O'Brart, D. P. S. (2018) · Journal of Cataract & Refractive Surgery · doi:10.1016/j.jcrs.2018.08.033 · Cited by 79
Self-citationFemtosecond laser–assisted cataract surgery: A review
Roberts, H. W., Day, A. C., & O'Brart, D. P. S. (2019) · European Journal of Ophthalmology · doi:10.1177/1120672119893291 · Cited by 77
Self-citationLaser-assisted cataract surgery versus standard ultrasound phacoemulsification cataract surgery
Narayan, A. R., Evans, J. R., O'Brart, D. P. S., Bunce, C., Gore, D. M., & Day, A. C. (2023) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd010735.pub3 · Cited by 77
Self-citationHow Ophthalmologists Can Decarbonize Eye Care
Sherry, B., Lee, S., Ramos Cadena, M. D. L. A., Laynor, G., Patel, S. R., Simon, M. D., Romanowski, E. G., Hochman, S. E., Schuman, J. S., Prescott, C., et al. (2023) · Ophthalmology · doi:10.1016/j.ophtha.2023.02.028 · Cited by 47
Carbon Emissions from Overuse of U.S. Health Care: Medical and Ethical Problems
Thiel, C. L., & Richie, C. (2022) · The Hastings Center Report · doi:10.1002/hast.1404 · Cited by 47
Metadata
- Authors
- Roberts, H. W., Wagh, V. K., Mullens, I. J. M., Borsci, S., Ni, M. Z., & O’Brart, D. P. S.
- Affiliations
- St Thomas' Hospital (GB)
- Imperial College London (GB)
- Corresponding author
- Roberts, Harry W
- Venue
- British Journal of Ophthalmology
- Publisher
- BMJ
- Published
- 2018-02-07
- Volume
- 102
- Issue
- 11
- Pages
- 1556-1563
- ISSN
- 0007-1161 (ISSN-L)
- 1468-2079
- OpenAlex
- W2787635812
- Cited by
- 26
- References
- 21
- Citations by year
- 2026: 1 · 2025: 1 · 2024: 1 · 2023: 6 · 2022: 3 · 2021: 5 · 2020: 4 · 2019: 3 · 2018: 2
- FWCI
- 5.36
- Type
- journal article
- Language
- en
- Open access
- green
- research.utwente.nl
- Licence
- other-oa
- Locations
- British Journal of Ophthalmology (publishedVersion)
- PubMed (publishedVersion)
- University of Twente Research Information (publishedVersion, other-oa)
- HighWire Press Open Archive (submittedVersion)
- Spiral (Imperial College London) (submittedVersion)
- University of Twente Research Information (submittedVersion, other-oa)
- Funders
- Alcon
- Topics
- Social Sciences › Decision Sciences › Management Science and Operations Research › Healthcare Operations and Scheduling Optimization
- Health Sciences › Medicine › Ophthalmology › Intraocular Surgery and Lenses
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Healthcare Quality and Management
- Keywords
- femtosecond laser-assisted cataract surgery, hub and spoke model, operating room productivity, phacoemulsification, surgical costs, operative time, cataract surgery
- MeSH terms
- Aged, Aged, 80 and over, Cataract Extraction, Female, Humans, Male, Middle Aged, Operating Rooms, Prospective Studies, Visual Acuity, Models, Organizational, Efficiency, Organizational, Models, Economic, Phacoemulsification, Pseudophakia, Lens Implantation, Intraocular, Laser Therapy, Operative Time
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.