Background: Prior work has demonstrated the near-perfect accuracy of a deep learning retinal image analysis system for diagnosing plus disease in retinopathy of prematurity (ROP). Here we assess the screening potential of this scoring system by determining its ability to detect all components of ROP diagnosis. Methods: Clinical examination and fundus photography were performed at seven participating centres. A deep learning system was trained to detect plus disease, generating a quantitative assessment of retinal vascular abnormality (the i-ROP plus score) on a 1–9 scale. Overall ROP disease category was established using a consensus reference standard diagnosis combining clinical and image-based diagnosis. Experts then ranked ordered a second data set of 100 posterior images according to overall ROP severity. Results: 4861 examinations from 870 infants were analysed. 155 examinations (3%) had a reference standard diagnosis of type 1 ROP. The i-ROP deep learning (DL) vascular severity score had an area under the receiver operating curve of 0.960 for detecting type 1 ROP. Establishing a threshold i-ROP DL score of 3 conferred 94% sensitivity, 79% specificity, 13% positive predictive value and 99.7% negative predictive value for type 1 ROP. There was strong correlation between expert rank ordering of overall ROP severity and the i-ROP DL vascular severity score (Spearman correlation coefficient=0.93; p<0.0001). Conclusion: The i-ROP DL system accurately identifies diagnostic categories and overall disease severity in an automated fashion, after being trained only on posterior pole vascular morphology. These data provide proof of concept that a deep learning screening platform could improve objectivity of ROP diagnosis and accessibility of screening.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/bjophthalmol-2018-313156

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 178

Metadata

Authors
Redd, T. K., Campbell, J. P., Brown, J. M., Kim, S. J., Ostmo, S., Chan, R. V. P., Dy, J., Erdogmus, D., Ioannidis, S., Kalpathy-Cramer, J., & Chiang, M. F.
Venue
British Journal of Ophthalmology
Publisher
BMJ
Published
2018-11-23
Volume
103
Issue
5
Pages
580-584
ISSN
  • 0007-1161 (ISSN-L)
  • 1468-2079
OpenAlex
W2901661131
Cited by
178
References
6
FWCI
9.29
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Evaluation of a deep learning image assessment system for detecting severe retinopathy of prematurity. https://app.cochat.ai/papers/10.1136/bjophthalmol-2018-313156
The paper
Redd, T. K., Campbell, J. P., Brown, J. M., Kim, S. J., Ostmo, S., Chan, R. V. P., Dy, J., Erdogmus, D., Ioannidis, S., Kalpathy-Cramer, J., & Chiang, M. F. (2019). Evaluation of a deep learning image assessment system for detecting severe retinopathy of prematurity. British Journal of Ophthalmology. https://doi.org/10.1136/bjophthalmol-2018-313156

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.