The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
The ingestible telemetric body core temperature sensor: a review of validity and exercise applications
Open accessAbstract
An ingestible telemetric temperature sensor for measuring body core temperature (T c) was first described 45 years ago, although the method has only recently gained widespread use for exercise applications. This review aims to (1) use Bland and Altman’s limits of agreement (LoA) method as a basis for quantitatively reviewing the agreement between intestinal sensor temperature (T intestinal), oesophageal temperature (T oesophageal) and rectal temperature (T rectal) across numerous previously published validation studies; (2) review factors that may affect agreement; and (3) review the application of this technology in field-based exercise studies. The agreement between T intestinal and T oesophageal is suggested to meet our delimitation for an acceptable level of agreement (ie, systematic bias <0.1°C and 95% LoA within ±0.4°C). The agreement between T intestinal and T rectal shows a significant systematic bias >0.1°C, although the 95% LoA is acceptable. T intestinal responds less rapidly than T oesophageal at the start or cessation of exercise or to a change in exercise intensity, but more rapidly than T rectal. When using this technology, care should be taken to ensure adequate control over sensor calibration and data correction, timing of ingestion and electromagnetic interference. The ingestible sensor has been applied successfully in numerous sport and occupational applications such as the continuous measurement of T c in deep sea saturation divers, distance runners and soldiers undertaking sustained military training exercises. It is concluded that the ingestible telemetric temperature sensor represents a valid index of T c and shows excellent utility for ambulatory field-based applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Atkinson, G., & Nevill, A. M. (1998) · Sports Medicine · doi:10.2165/00007256-199826040-00002 · Cited by 3,779
Influence of body temperature on the development of fatigue during prolonged exercise in the heat
González-Alonso, J., Teller, C., Andersen, S. L., Jensen, F. B., Hyldig, T., & Nielsen, B. (1999) · Journal of Applied Physiology · doi:10.1152/jappl.1999.86.3.1032 · Cited by 1,129
Human performance physiology and environmental medicine at terrestrial extremes
PANDOLF, K. B., Sawka, M. N., & Gonzalez, R. R. (1988) · Medical Entomology and Zoology · Cited by 401
Telemetry pill measurement of core temperature in humans during active heating and cooling
O'BRIEN, C., HOYT, R. W., BULLER, M. J., CASTELLANI, J. W., & YOUNG, A. J. (1998) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199803000-00020 · Cited by 219
Statistical methods for assessing agreement
Fitzmaurice, G. (2002) · Nutrition · doi:10.1016/s0899-9007(02)00802-x · Cited by 202
Continuous Thermoregulatory Responses to Mass-Participation Distance Running in Heat
BYRNE, C., LEE, J. K. W., CHEW, S. A. N., LIM, C. L., & TAN, E. Y. M. (2006) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000218134.74238.6a · Cited by 196
Self-citationThermoregulatory responses during competitive marathon running
Maron, M. B., Wagner, J. A., & Horvath, S. M. (1977) · Journal of Applied Physiology · doi:10.1152/jappl.1977.42.6.909 · Cited by 191
Lim, C. L., & Mackinnon, L. T. (2006) · Sports Medicine · doi:10.2165/00007256-200636010-00004 · Cited by 176
Self-citationPhysiological Responses to Acute Exercise-Heat Stress
Sawka, M. N., & Wenger, C. B. (1988) · Defense Technical Information Center (DTIC) · Cited by 148
Core temperature and hydration status during an Ironman triathlon
Laursen, P. B., Suriano, R., Quod, M. J., Lee, H., Abbiss, C. R., Nosaka, K., Martin, D. T., & Bishop, D. J. (2006) · British Journal of Sports Medicine · doi:10.1136/bjsm.2005.022426 · Cited by 148
Thermoregulation during marathon running in cool, moderate, and hot environments
Adams, W. C., Fox, R. H., Fry, A. J., & MacDonald, I. C. (1975) · Journal of Applied Physiology · doi:10.1152/jappl.1975.38.6.1030 · Cited by 147
Validation of a new telemetric core temperature monitor
McKenzie, J. E., & Osgood, D. W. (2004) · Journal of Thermal Biology · doi:10.1016/j.jtherbio.2004.08.020 · Cited by 147
The Validity and Reliability of Intestinal Temperature during Intermittent Running
Gant, N., Atkinson, G., & Williams, C. (2006) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000233800.69776.ef · Cited by 135
Physiology and Pathophysiology of Temperature Regulation
Blatteis, C. M. (1998) · WORLD SCIENTIFIC eBooks · doi:10.1142/3507 · Cited by 132
American College of Sports Medicine position stand. Heat and cold illnesses during distance running.
Armstrong, L. E., Epstein, Y., GREENLEAF, J. E., Haymes, E. M., Hubbard, R. W., Roberts, W. O., & Thompson, P. D. (1996) · PubMed · Cited by 115
Edwards, B., Waterhouse, J. M., Reilly, T. P., & Atkinson, G. (2002) · Chronobiology International · doi:10.1081/cbi-120004227 · Cited by 106
Lee, S. M. C., Williams, W. J., & Schneider, S. M. (2000) · PubMed · Cited by 103
Edwards, A. M., & Clark, N. A. (2006) · British Journal of Sports Medicine · doi:10.1136/bjsm.2005.021980 · Cited by 101
Validation of a temperature telemetry system during moderate and strenuous exercise
Kolka, M. A., Quigley, M. D., Blanchard, L., Toyota, D. A., & Stephenson, L. A. (1993) · Journal of Thermal Biology · doi:10.1016/0306-4565(93)90004-d · Cited by 90
Effect of cold exposure on various sites of core temperature measurements
Livingstone, S. D., Grayson, J. K., Frim, J., Allen, C. L., & Limmer, R. E. (1983) · Journal of Applied Physiology · doi:10.1152/jappl.1983.54.4.1025 · Cited by 74
Godek, S. F., Bartolozzi, A. R., Burkholder, R., Sugarman, E., & Dorshimer, G. W. (2006) · Europe PMC (PubMed Central) · Cited by 70
Use of an ingestible telemetry sensor to measure core temperature under chemical protective clothing
Kolka, M. A., Levine, L., & Stephenson, L. A. (1997) · Journal of Thermal Biology · doi:10.1016/s0306-4565(97)00032-6 · Cited by 61
Energy Expenditure in Men and Women during 54 h of Exercise and Caloric Deprivation
Castellani, J. W., DeLany, J. P., O’Brien, C., Hoyt, R. W., Santee, W. R., & Young, A. (2006) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000218122.59968.eb · Cited by 58
Fowkes-Godek, S., Godek, J. J., & Bartolozzi, A. R. (2004) · PubMed · Cited by 58
Ventilation volume as a stimulus to spontaneous ventilation after prolonged artificial ventilation
Smith, A. C., Spalding, J. M. K., & Watson, W. E. (1962) · The Journal of Physiology · doi:10.1113/jphysiol.1962.sp006830 · Cited by 41
Lim, C. L., Chung, K. K., & Hock, L. L. K. (1997) · Military Medicine · doi:10.1093/milmed/162.9.623 · Cited by 37
Self-citationPhysiology of accidental hypothermia in the mountains: a forgotten story
Ainslie, P. N., & Reilly, T. P. (2003) · British Journal of Sports Medicine · doi:10.1136/bjsm.37.6.548 · Cited by 33
Prediction of oesophageal temperatures from core temperatures measured at other sites in man
Gibson, T. M., Redman, P. J., & Belyavin, A. (1981) · Clinical Physics and Physiological Measurement · doi:10.1088/0143-0815/2/4/001 · Cited by 25
Evaluation of miniature data loggers for body temperature measurement during sporting activities
Fuller, A., Oosthuyse, T., Maloney, S. K., & Mitchell, D. (1999) · European Journal of Applied Physiology · doi:10.1007/s004210050518 · Cited by 17
Research works printed but not linked: 15
- 1996, Med Sci Sports Exerc, 28, 1
- 1961, New Sci, 16, 419
- 1988, Johns Hopkins APL Tech Dig, 9, 16
- 1993, Aviat Space Environ Med, 64, 760
- 2001, Pro Aust Physiol Pharmacol Soc, 32, 28
- 1998, Prehosp Emerg Care, 2, 280, 10.1080/10903129808958880 · doi:10.1080/10903129808958880
- 2000, J Swimming Res, 14, 26
- 2001, Undersea Hyperb Med, 28, 149
- 2004, J Athl Train, 39, 235
- 2006, J Athl Train, 41, 8
- 1966, J Physiol, 184, 581, 10.1113/jphysiol.1966.sp007932 · doi:10.1113/jphysiol.1966.sp007932
- 1971, Int J Biometeorol, 15, 176, 10.1007/BF01803894 · doi:10.1007/bf01803894
- 1991, Int J Radiat Oncol Biol Phys, 21, 1353, 10.1016/0360-3016(91)90297-H · doi:10.1016/0360-3016(91)90297-h
- 1989, J Physiol, 412, 42
- 1990, J Physiol, 430, 93
Cited by
Flexible Sensing Electronics for Wearable/Attachable Health Monitoring
Wang, X., Liu, Z., & Zhang, T. (2017) · Small · doi:10.1002/smll.201602790 · Cited by 1,075
Périard, J. D., Eijsvogels, T. M. H., & Daanen, H. A. M. (2021) · Physiological Reviews · doi:10.1152/physrev.00038.2020 · Cited by 647
Considerations for the measurement of core, skin and mean body temperatures
Taylor, N. A. S., Tipton, M. J., & Kenny, G. P. (2014) · Journal of Thermal Biology · doi:10.1016/j.jtherbio.2014.10.006 · Cited by 420
First Decade of Interfacial Iontronic Sensing: From Droplet Sensors to Artificial Skins
Chang, Y., Wang, L., Li, R., Zhang, Z., Wang, Q., Yang, J., Guo, C. F., & Pan, T. (2021) · Advanced Materials · doi:10.1002/adma.202003464 · Cited by 381
Human Thermoregulation and Measurement of Body Temperature in Exercise and Clinical Settings
Lim, C. L., Byrne, C., & Lee, J. K. (2008) · Annals of the Academy of Medicine, Singapore · doi:10.47102/annals-acadmedsg.v37n4p347 · Cited by 373
Self-citation
Metadata
- Authors
- Byrne, C., & Lim, C. L.
- Venue
- British Journal of Sports Medicine
- Publisher
- BMJ
- Published
- 2006-12-18
- Volume
- 41
- Issue
- 3
- Pages
- 126-133
- ISSN
- 0306-3674 (ISSN-L)
- 1473-0480
- OpenAlex
- W2141006808
- Cited by
- 456
- References
- 30
- FWCI
- 3.72
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.