The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
The ingestible telemetric body core temperature sensor: a review of validity and exercise applications
Open accessAbstract
An ingestible telemetric temperature sensor for measuring body core temperature (T c) was first described 45 years ago, although the method has only recently gained widespread use for exercise applications. This review aims to (1) use Bland and Altman’s limits of agreement (LoA) method as a basis for quantitatively reviewing the agreement between intestinal sensor temperature (T intestinal), oesophageal temperature (T oesophageal) and rectal temperature (T rectal) across numerous previously published validation studies; (2) review factors that may affect agreement; and (3) review the application of this technology in field-based exercise studies. The agreement between T intestinal and T oesophageal is suggested to meet our delimitation for an acceptable level of agreement (ie, systematic bias <0.1°C and 95% LoA within ±0.4°C). The agreement between T intestinal and T rectal shows a significant systematic bias >0.1°C, although the 95% LoA is acceptable. T intestinal responds less rapidly than T oesophageal at the start or cessation of exercise or to a change in exercise intensity, but more rapidly than T rectal. When using this technology, care should be taken to ensure adequate control over sensor calibration and data correction, timing of ingestion and electromagnetic interference. The ingestible sensor has been applied successfully in numerous sport and occupational applications such as the continuous measurement of T c in deep sea saturation divers, distance runners and soldiers undertaking sustained military training exercises. It is concluded that the ingestible telemetric temperature sensor represents a valid index of T c and shows excellent utility for ambulatory field-based applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Atkinson, G., & Nevill, A. M. (1998) · Sports Medicine · doi:10.2165/00007256-199826040-00002 · Cited by 3,779
Influence of body temperature on the development of fatigue during prolonged exercise in the heat
González-Alonso, J., Teller, C., Andersen, S. L., Jensen, F. B., Hyldig, T., & Nielsen, B. (1999) · Journal of Applied Physiology · doi:10.1152/jappl.1999.86.3.1032 · Cited by 1,129
Human performance physiology and environmental medicine at terrestrial extremes
PANDOLF, K. B., Sawka, M. N., & Gonzalez, R. R. (1988) · Medical Entomology and Zoology · Cited by 401
Telemetry pill measurement of core temperature in humans during active heating and cooling
O'BRIEN, C., HOYT, R. W., BULLER, M. J., CASTELLANI, J. W., & YOUNG, A. J. (1998) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199803000-00020 · Cited by 219
Statistical methods for assessing agreement
Fitzmaurice, G. (2002) · Nutrition · doi:10.1016/s0899-9007(02)00802-x · Cited by 202
Continuous Thermoregulatory Responses to Mass-Participation Distance Running in Heat
BYRNE, C., LEE, J. K. W., CHEW, S. A. N., LIM, C. L., & TAN, E. Y. M. (2006) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000218134.74238.6a · Cited by 196
Self-citationThermoregulatory responses during competitive marathon running
Maron, M. B., Wagner, J. A., & Horvath, S. M. (1977) · Journal of Applied Physiology · doi:10.1152/jappl.1977.42.6.909 · Cited by 191
Lim, C. L., & Mackinnon, L. T. (2006) · Sports Medicine · doi:10.2165/00007256-200636010-00004 · Cited by 176
Self-citationPhysiological Responses to Acute Exercise-Heat Stress
Sawka, M. N., & Wenger, C. B. (1988) · Defense Technical Information Center (DTIC) · Cited by 148
Research works printed but not linked: 15
- 1996, Med Sci Sports Exerc, 28, 1
- 1961, New Sci, 16, 419
- 1988, Johns Hopkins APL Tech Dig, 9, 16
- 1993, Aviat Space Environ Med, 64, 760
- 2001, Pro Aust Physiol Pharmacol Soc, 32, 28
- 1998, Prehosp Emerg Care, 2, 280, 10.1080/10903129808958880 · doi:10.1080/10903129808958880
- 2000, J Swimming Res, 14, 26
- 2001, Undersea Hyperb Med, 28, 149
- 2004, J Athl Train, 39, 235
- 2006, J Athl Train, 41, 8
- 1966, J Physiol, 184, 581, 10.1113/jphysiol.1966.sp007932 · doi:10.1113/jphysiol.1966.sp007932
- 1971, Int J Biometeorol, 15, 176, 10.1007/BF01803894 · doi:10.1007/bf01803894
- 1991, Int J Radiat Oncol Biol Phys, 21, 1353, 10.1016/0360-3016(91)90297-H · doi:10.1016/0360-3016(91)90297-h
- 1989, J Physiol, 412, 42
- 1990, J Physiol, 430, 93
Cited by
Flexible Sensing Electronics for Wearable/Attachable Health Monitoring
Wang, X., Liu, Z., & Zhang, T. (2017) · Small · doi:10.1002/smll.201602790 · Cited by 1,075
Périard, J. D., Eijsvogels, T. M. H., & Daanen, H. A. M. (2021) · Physiological Reviews · doi:10.1152/physrev.00038.2020 · Cited by 647
Considerations for the measurement of core, skin and mean body temperatures
Taylor, N. A. S., Tipton, M. J., & Kenny, G. P. (2014) · Journal of Thermal Biology · doi:10.1016/j.jtherbio.2014.10.006 · Cited by 420
First Decade of Interfacial Iontronic Sensing: From Droplet Sensors to Artificial Skins
Chang, Y., Wang, L., Li, R., Zhang, Z., Wang, Q., Yang, J., Guo, C. F., & Pan, T. (2021) · Advanced Materials · doi:10.1002/adma.202003464 · Cited by 381
Human Thermoregulation and Measurement of Body Temperature in Exercise and Clinical Settings
Lim, C. L., Byrne, C., & Lee, J. K. (2008) · Annals of the Academy of Medicine, Singapore · doi:10.47102/annals-acadmedsg.v37n4p347 · Cited by 373
Self-citationA pH-responsive supramolecular polymer gel as an enteric elastomer for use in gastric devices
Zhang, S., Bellinger, A. M., Glettig, D. L., Barman, R., Lee, Y.-A. L., Zhu, J., Cleveland, C., Montgomery, V. A., Gu, L., Nash, L. D., et al. (2015) · Nature Materials · doi:10.1038/nmat4355 · Cited by 326
Schlader, Z. J., Simmons, S. E., Stannard, S. R., & Mündel, T. (2011) · Physiology & Behavior · doi:10.1016/j.physbeh.2011.02.002 · Cited by 281
Circadian rhythm of wrist temperature in normal-living subjects
Sarabia, J. A., Rol, M. A., Mendiola, P., & Madrid, J. A. (2008) · Physiology & Behavior · doi:10.1016/j.physbeh.2008.08.005 · Cited by 222
The effect of stress on core and peripheral body temperature in humans
Vinkers, C. H., Penning, R., Hellhammer, J., Verster, J. C., Klaessens, J. H. G. M., Olivier, B., & Kalkman, C. J. (2013) · Stress · doi:10.3109/10253890.2013.807243 · Cited by 220
Circadian rhythmicity of body temperature and metabolism
Refinetti, R. (2020) · Temperature · doi:10.1080/23328940.2020.1743605 · Cited by 155
Thermal pleasure in built environments: alliesthesia in different thermoregulatory zones
Parkinson, T., de Dear, R., & Candido, C. (2016) · Building Research & Information · doi:10.1080/09613218.2015.1059653 · Cited by 126
Reliability and validity of the CORE sensor to assess core body temperature during cycling exercise
Verdel, N., Podlogar, T., Ciuha, U., Holmberg, H.-C., Debevec, T., & Supej, M. (2021) · Sensors · doi:10.3390/s21175932 · Cited by 89
Klous, L., de Ruiter, C. J., Scherrer, S., Gerrett, N., & Daanen, H. A. M. (2021) · European Journal of Applied Physiology · doi:10.1007/s00421-020-04562-8 · Cited by 86
Jansen, S. W., Akintola, A. A., Roelfsema, F., van der Spoel, E., Cobbaert, C. M., Ballieux, B. E., Egri, P., Kvarta-Papp, Z., Gereben, B., Fekete, C., et al. (2015) · Scientific Reports · doi:10.1038/srep11525 · Cited by 82
Influence of post-warm-up recovery time on swim performance in international swimmers
West, D. J., Dietzig, B. M., Bracken, R. M., Cunningham, D. J., Crewther, B. T., Cook, C. J., & Kilduff, L. P. (2013) · Journal of Science and Medicine in Sport · doi:10.1016/j.jsams.2012.06.002 · Cited by 81
Kilduff, L. P., West, D. J., Williams, N., & Cook, C. J. (2013) · Journal of Science and Medicine in Sport · doi:10.1016/j.jsams.2012.11.889 · Cited by 78
Micic, G., de Bruyn, A., Lovato, N., Wright, H., Gradisar, M., Ferguson, S., Burgess, H. J., & Lack, L. (2013) · Journal of Sleep Research · doi:10.1111/jsr.12072 · Cited by 76
Jolicoeur Desroches, A., Naulleau, C., Deshayes, T. A., Pancrate, T., & Goulet, E. D. B. (2023) · Journal of Thermal Biology · doi:10.1016/j.jtherbio.2023.103622 · Cited by 19
Top 10 research questions related to preventing sudden death in sport and physical activity
Katch, R. K., Scarneo, S. E., Adams, W. M., Armstrong, L. E., Belval, L. N., Stamm, J. M., & Casa, D. J. (2017) · Research Quarterly for Exercise and Sport · doi:10.1080/02701367.2017.1342201 · Cited by 11
Heat Impacts on Work, Human Performance, and Daily Life
Kjellstrom, T., Lemke, B., Matthias Otto, P., Hyatt, O. M., Briggs, D. J., & Freyberg, C. A. (2015) · Climate Change and Public Health · doi:10.1093/med/9780190202453.003.0004 · Cited by 9
Chen, S., Peng, C., Yang, B., Lin, J., Zhou, L., Jiang, Z., Liu, Z., Liu, Y., & Tang, L. (2026) · npj Artificial Intelligence · doi:10.1038/s44387-026-00083-5 · Cited by 9
Metadata
- Authors
- Byrne, C., & Lim, C. L.
- Venue
- British Journal of Sports Medicine
- Publisher
- BMJ
- Published
- 2006-12-18
- Volume
- 41
- Issue
- 3
- Pages
- 126-133
- ISSN
- 0306-3674 (ISSN-L)
- 1473-0480
- OpenAlex
- W2141006808
- Cited by
- 456
- References
- 30
- FWCI
- 3.72
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.