Diagnostic accuracy of ultrasonography, MRI and MR arthrography in the characterisation of rotator cuff disorders: a systematic review and meta-analysis
Open accessThe DOI matches its Crossref record; 48 of the 48 references it cites were found in a registry or an index.
Abstract
Background: Different diagnostic imaging modalities, such as ultrasonography (US), MRI, MR arthrography (MRA) are commonly used for the characterisation of rotator cuff (RC) disorders. Since the most recent systematic reviews on medical imaging, multiple diagnostic studies have been published, most using more advanced technological characteristics. The first objective was to perform a meta-analysis on the diagnostic accuracy of medical imaging for characterisation of RC disorders. Since US is used at the point of care in environments such as sports medicine, a secondary analysis assessed accuracy by radiologists and non-radiologists. Methods: A systematic search in three databases was conducted. Two raters performed data extraction and evaluation of risk of bias independently, and agreement was achieved by consensus. Hierarchical summary receiver-operating characteristic package was used to calculate pooled estimates of included diagnostic studies. Results: Diagnostic accuracy of US, MRI and MRA in the characterisation of full-thickness RC tears was high with overall estimates of sensitivity and specificity over 0.90. As for partial RC tears and tendinopathy, overall estimates of specificity were also high (>0.90), while sensitivity was lower (0.67–0.83). Diagnostic accuracy of US was similar whether a trained radiologist, sonographer or orthopaedist performed it. Conclusions: Our results show the diagnostic accuracy of US, MRI and MRA in the characterisation of full-thickness RC tears. Since full thickness tear constitutes a key consideration for surgical repair, this is an important characteristic when selecting an imaging modality for RC disorder. When considering accuracy, cost, and safety, US is the best option.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Liberati, A., Altman, D. G., Tetzlaff, J., Mulrow, C., Gøtzsche, P. C., Ioannidis, J. P. A., Clarke, M., Devereaux, P. J., Kleijnen, J., & Moher, D. (2009) · PLoS Medicine · doi:10.1371/journal.pmed.1000100 · Cited by 28,164
Liberati, A., Altman, D. G., Tetzlaff, J., Mulrow, C., Gotzsche, P. C., Ioannidis, J. P. A., Clarke, M., Devereaux, P. J., Kleijnen, J., & Moher, D. (2009) · BMJ · doi:10.1136/bmj.b2700 · Cited by 17,648
QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group* (2011) · Annals of Internal Medicine · doi:10.7326/0003-4819-155-8-201110180-00009 · Cited by 14,199 · cited 1×
“The classical con fi dence interval (CI) presumes that differences in Sn and Sp between studies are caused only by a statistical instability related to sampling or measurement errors.”
Evaluating non-randomised intervention studies
Deeks, J., Dinnes, J., D'Amico, R., Sowden, A., Sakarovitch, C., Song, F., Petticrew, M., & Altman, D. (2003) · Health Technology Assessment · doi:10.3310/hta7270 · Cited by 2,907
NEER, C. S. (1983) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198303000-00010 · Cited by 1,335
Egger, M., Jüni, P., Bartlett, C., Holenstein, F., & Sterne, J. (2003) · Health Technology Assessment · doi:10.3310/hta7010 · Cited by 1,181
Sources of Variation and Bias in Studies of Diagnostic Accuracy: A Systematic Review
Whiting, P., Rutjes, A. W. S., Reitsma, J. B., Glas, A. S., Bossuyt, P. M. M., & Kleijnen, J. (2004) · Annals of Internal Medicine · doi:10.7326/0003-4819-140-3-200402030-00010 · Cited by 798
de Jesus, J. O., Parker, L., Frangos, A. J., & Nazarian, L. N. (2009) · American Journal of Roentgenology · doi:10.2214/ajr.08.1241 · Cited by 608
QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Rutjes, A. W., Westwood, M. E., Mallett, S. V., Deeks, J. J., Reitsma, J. B., Leeflang, M., Sterne, J. A. C., & Bossuyt, P. M. (2011) · Data Archiving and Networked Services (DANS) · doi:10.1059/0003-4819-155-8-201110180-00009 · Cited by 601
Teefey, S. A., Hasan, S. A., Middleton, W. D., Patel, M., Wright, R. W., & Yamaguchi, K. (2000) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-200004000-00005 · Cited by 514
Teefey, S. A., Rubin, D. A., Middleton, W. D., et al. (2004) · PubMed · Cited by 490
Shoulder disorders in general practice: prognostic indicators of outcome.
van der Windt, D., Koes, B. W., Boeke, A. J. P., Devillé, W. L. J. M., de Jong, B. A., & Bouter, L. M. (1996) · Europe PMC (PubMed Central) · Cited by 476
TEEFEY, S. A., RUBIN, D. A., MIDDLETON, W. D., HILDEBOLT, C. F., LEIBOLD, R. A., & YAMAGUCHI, K. (2004) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200404000-00007 · Cited by 476
Magnetic resonance imaging of the shoulder. Sensitivity, specificity, and predictive value.
Iannotti, J. P., Zlatkin, M. B., Esterhai, J. L., Kressel, H. Y., Dalinka, M. K., & Spindler, K. P. (1991) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199173010-00004 · Cited by 439
Teefey, S. A., Hasan, S. A., Middleton, W. D., Patel, M., Wright, R. W., & Yamaguchi, K. (2000) · PubMed · Cited by 428
Dinnes, J., Loveman, E., McIntyre, L., & Waugh, N. (2003) · Health Technology Assessment · doi:10.3310/hta7290 · Cited by 355
Systematic reviews and meta-analyses of diagnostic test accuracy
Leeflang, M. M. G. (2014) · Clinical Microbiology and Infection · doi:10.1111/1469-0691.12474 · Cited by 318
Shoulder disorders: a state-of-the-art review
van der Heijden, G. J. M. G. (1999) · Best Practice & Research Clinical Rheumatology · doi:10.1053/berh.1999.0021 · Cited by 294
Lenza, M., Buchbinder, R., Takwoingi, Y., Johnston, R. V., Hanchard, N. C., & Faloppa, F. (2013) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd009020.pub2 · Cited by 267
Wiener, S. N., & Seitz, W. H. (1993) · American Journal of Roentgenology · doi:10.2214/ajr.160.1.8416605 · Cited by 236
Read, J. W., & Perko, M. (1998) · Journal of Shoulder and Elbow Surgery · doi:10.1016/s1058-2746(98)90055-6 · Cited by 188
Smith, T. O., Back, T., Toms, A. P., & Hing, C. B. (2011) · Clinical Radiology · doi:10.1016/j.crad.2011.05.007 · Cited by 174
Aly, A.-R., Rajasekaran, S., & Ashworth, N. L. (2014) · British Journal of Sports Medicine · doi:10.1136/bjsports-2014-093573 · Cited by 169
Rotator cuff tears: assessment with MR arthrography in 275 patients with arthroscopic correlation
Waldt, S., Bruegel, M., Müeller, D., Holzapfel, K., Imhoff, A. B., Rummeny, E. J., & Woertler, K. (2006) · European Radiology · doi:10.1007/s00330-006-0370-7 · Cited by 167
Adams, C. R., Schoolfield, J. D., & Burkhart, S. S. (2010) · Arthroscopy The Journal of Arthroscopic and Related Surgery · doi:10.1016/j.arthro.2010.02.028 · Cited by 159
Alqunaee, M., Galvin, R., & Fahey, T. P. (2012) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2011.08.035 · Cited by 152
Ottenheijm, R. P. G., Jansen, M. J., Staal, J. B., den Bruel, A. V., Weijers, R. E., de Bie, R. A., & Dinant, G. (2010) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2010.07.017 · Cited by 136
Vlychou, M., Dailiana, Z. H., Fotiadou, A. N., Papanagiotou, M., Fezoulidis, I. V., & Malizos, Κ. Ν. (2008) · Acta Radiologica · doi:10.1080/02841850802600764 · Cited by 126
Detection of rotator cuff tears: the value of MRI following ultrasound
Rutten, M. J. C. M., Spaargaren, G.-J., van Loon, T., Malefijt, M. C. D. W., Kiemeney, L. A. L. M., & Jager, G. J. (2009) · European Radiology · doi:10.1007/s00330-009-1561-9 · Cited by 121
Methods Guide for Medical Test Reviews
Chang, S., Matchar, D. B., Smetana, G. W., & Umscheid, C. A. (2012) · Cited by 117
Chapter 8: Meta-analysis of Test Performance When There is a “Gold Standard”
Trikalinos, T. A., Balion, C. M., Coleman, C. I., Griffith, L. E., Santaguida, P. L., Vandermeer, B., & Fu, R. F. (2012) · Journal of General Internal Medicine · doi:10.1007/s11606-012-2029-1 · Cited by 104
Smith, T. O., Daniell, H., Geere, J., Toms, A. P., & Hing, C. B. (2012) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2011.12.008 · Cited by 100
Finnoff, J. T., Hall, M. M., Adams, E. S., Berkoff, D. J., Concoff, A. L., Dexter, W. W., & Smith, J. (2014) · British Journal of Sports Medicine · doi:10.1136/bjsports-2014-094219 · Cited by 94
Shoulder MRI: arthroscopic correlation with emphasis on partial tears.
Traughber, P., & Te, G. (1992) · PubMed · Cited by 82
Diagnostic ultrasound of the shoulder—a method for experts only?
Moosmayer, S., & Smith, H. (2005) · Acta Orthopaedica · doi:10.1080/17453670510041484 · Cited by 69
Sonographic Evaluation of the Rotator Cuff: Accuracy in Patients Without Prior Surgery
Mack, L. A., GANNON, M. K., Kilcoyne, R. F., & Matsen, F. A. (1988) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198809000-00005 · Cited by 64
Moosmayer, S., Heir, S., & Smith, H. (2006) · Journal of Clinical Ultrasound · doi:10.1002/jcu.20286 · Cited by 64
FARIN, P. U., & Jaroma, H. (1996) · Journal of Ultrasound in Medicine · doi:10.7863/jum.1996.15.3.221 · Cited by 62
Indications for Surgery in Clinical Outcome Studies of Rotator Cuff Repair
Marx, R. G., Koulouvaris, P., Chu, S. K. W., & Levy, B. A. (2008) · Clinical Orthopaedics and Related Research · doi:10.1007/s11999-008-0585-9 · Cited by 59
Choo, H. J., Lee, S. J., Kim, O.-H., Seo, S. S., & Kim, J. H. (2012) · Radiology · doi:10.1148/radiol.11111261 · Cited by 56
Zlatkin, M. B., Hoffman, C. J., & Shellock, F. G. (2004) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20040 · Cited by 48
The Use of Magnetic Resonance Arthrography to Detect Partial-Thickness Rotator Cuff Tears
Stetson, W. B., Phillips, T., & Deutsch, A. L. (2005) · Journal of Bone and Joint Surgery · doi:10.2106/jbjs.e.00509 · Cited by 46
Schreinemachers, S. A., van der Hulst, V. P. M., Willems, W. J., Bipat, S., & van der Woude, H.-J. (2009) · Skeletal Radiology · doi:10.1007/s00256-009-0680-3 · Cited by 41
Jung, J., Jee, W.-H., Chun, H. J., Ahn, M. I., & Kim, Y. (2009) · Acta Radiologica · doi:10.3109/02841850903300298 · Cited by 39
Jung, J., Jee, W.-H., Park, M. Y., Lee, S. Y., & Kim, Y. (2012) · Skeletal Radiology · doi:10.1007/s00256-012-1361-1 · Cited by 33
Diagnostic value of clinical tests for degenerative rotator cuff disease in medical practice
Lasbleiz, S., Quintero, N., Ea, K., Petrover, D., Aout, M., Laredo, J. D., Vicaut, É., Bardin, T., Orcel, P., & Beaudreuil, J. (2014) · Annals of Physical and Rehabilitation Medicine · doi:10.1016/j.rehab.2014.04.001 · Cited by 30
Östör, A., Richards, C., Tytherleigh-Strong, G., Bearcroft, P., Prevost, A., Speed, C., & Hazleman, B. (2013) · Clinical Rheumatology · doi:10.1007/s10067-013-2260-0 · Cited by 25
Stoppino, L. P., Ciuffreda, P., Rossi, M., Lelario, M., Bristogiannis, C., Vinci, R., Genovese, E. A., & Macarini, L. (2013) · MUSCULOSKELETAL SURGERY · doi:10.1007/s12306-013-0289-5 · Cited by 11
Cited by
Bedi, A., Bishop, J., Keener, J., Lansdown, D. A., Levy, O., MacDonald, P., Maffulli, N., Oh, J. H., Sabesan, V. J., Sanchez-Sotelo, J., et al. (2024) · Nature Reviews Disease Primers · doi:10.1038/s41572-024-00492-3 · Cited by 206
Metadata
- Authors
- Roy, J.-S., Braën, C., Leblond, J., Desmeules, F., Dionne, C. E., MacDermid, J. C., Bureau, N. J., & Frémont, P.
- Venue
- British Journal of Sports Medicine
- Publisher
- BMJ
- Published
- 2015-02-11
- Volume
- 49
- Issue
- 20
- Pages
- 1316-1328
- ISSN
- 0306-3674 (ISSN-L)
- 1473-0480
- OpenAlex
- W2108001355
- Cited by
- 319
- References
- 48
- FWCI
- 5.82
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.