The DOI matches its Crossref record.
Continuous subcutaneous insulin infusion: an approach to achieving normoglycaemia.
Open accessAbstract
A study was performed to examine the feasibility of achieving long periods of near-normoglycaemia in patients with diabetes mellitus by giving a continuous subcutaneous infusion of insulin solution from a miniature, battery-driven, syringe pump. Twelve insulin-dependent diabetics had their insulin pumped through a subcutaneously implanted, fine nylon cannula; the basal infusion rate was electronically stepped up eightfold before meals. The blood glucose profile of these patients was closely monitored during the 24 hours of the subcutaneous infusion and compared with the profile on a control day, when the patients were managed with their usual subcutaneous insulin. Diet and exercise were standardised on both days. In five out of 14 studies the subcutaneous insulin infusion significantly lowered the mean blood glucose concentration without producing hypoglycaemic symptoms; in another six patients the mean blood glucose concentration was maintained. As assessed by the M value the level of control was statistically improved in six out of 14 studies by the infusion method and maintained in six other patients. To assess the effects of blood glucose control on diabetic microvascular disease it will be necessary to achieve long-term normoglycaemia in selected diabetics. The results of this preliminary study suggest that a continuous subcutaneous insulin infusion may be a means of maining physiological glucose concentrations in diabetics. Though several problems remain--for example, in determining the rate of infusion--longer-term studies with the miniature infusion pumps are now needed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Artificial Pancreas: Past, Present, Future
Cobelli, C., Renard, E., & Kovatchev, B. (2011) · Diabetes · doi:10.2337/db11-0654 · Cited by 600
White, N. H., Skor, D. A., Cryer, P. E., Levandoski, L. A., Bier, D. M., & Santiago, J. V. (1983) · New England Journal of Medicine · doi:10.1056/nejm198303033080903 · Cited by 391
Jeitler, K., Horvath, K., Berghold, A., Gratzer, T. W., Neeser, K., Pieber, T. R., & Siebenhofer, A. (2008) · Diabetologia · doi:10.1007/s00125-008-0974-3 · Cited by 375
Amiel, S. A., Tamborlane, W. V., Simonson, D. C., & Sherwin, R. S. (1987) · New England Journal of Medicine · doi:10.1056/nejm198705283162205 · Cited by 309
Tanenbaum, M. L., Hanes, S. J., Miller, K. M., Naranjo, D., Bensen, R., & Hood, K. K. (2017) · Diabetes Care · doi:10.2337/dc16-1536 · Cited by 296
Metadata
- Authors
- Pickup, J. C., Keen, H., Parsons, J. A., & Alberti, K. G.
- Venue
- BMJ
- Publisher
- BMJ
- Published
- 1978-01-28
- Volume
- 1
- Issue
- 6107
- Pages
- 204-207
- ISSN
- 0007-1447 (ISSN-L)
- 1468-5833
- OpenAlex
- W2077270061
- Cited by
- 563
- References
- 0
- FWCI
- 30.43
- Type
- journal article
- Language
- en
- Open access
- bronze
- Licence
- www.bmj.com/company/legal-information/terms-conditions/legal-information/tdm-licencepolicy (tdm)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Continuous subcutaneous insulin infusion: an approach to achieving normoglycaemia. https://app.cochat.ai/papers/10.1136/bmj.1.6107.204
- The paper
- Pickup, J. C., Keen, H., Parsons, J. A., & Alberti, K. G. (1978). Continuous subcutaneous insulin infusion: an approach to achieving normoglycaemia. BMJ. https://doi.org/10.1136/bmj.1.6107.204
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.