Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 197

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Clinical usefulness of estimation of serum fructosamine concentration as a screening test for diabetes mellitus.

Open access
Baker, J R, O'Connor, J P, Metcalf, P A, Lawson, M R, Johnson, R N · 1983 · BMJ

Abstract

Fructosamine, a putative measure of serum glycosylated proteins, was measured in 74 subjects referred for oral glucose tolerance tests. A normal range (mean (2 SD] of 1.6 (0.4) mmol/l (40(10) mg/100 ml) derive from results obtained in 83 healthy non-diabetic volunteers permitted the detection of 15 out of 17 (88%) subjects with proved diabetes and yielded only five (9%) false positive diagnoses. Fructosamine concentrations correlated significantly (p less than 0.001) with fasting plasma glucose concentrations (r = 0.76) and glycosylated haemoglobin concentrations (r = 0.70). A longitudinal study suggested that fructosamine concentration was an index of intermediate term (one to three weeks) blood glucose control. Fructosamine concentration was not related to uraemia and did not depend on albumin or total protein concentrations, provided that serum albumin concentrations remained above 30 g/l. Estimation of fructosamine concentrations is a fully automated procedure and may provide a simple means of screening for diabetes mellitus.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/bmj.287.6396.863

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 197

Metadata

Authors
Baker, J. R., O'Connor, J. P., Metcalf, P. A., Lawson, M. R., & Johnson, R. N.
Venue
BMJ
Publisher
BMJ
Published
1983-09-24
Volume
287
Issue
6396
Pages
863-867
ISSN
  • 0007-1447 (ISSN-L)
  • 1468-5833
OpenAlex
W2043801853
Cited by
197
References
2
FWCI
4.75
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Clinical usefulness of estimation of serum fructosamine concentration as a screening test for diabetes mellitus. https://app.cochat.ai/papers/10.1136/bmj.287.6396.863
The paper
Baker, J. R., O'Connor, J. P., Metcalf, P. A., Lawson, M. R., & Johnson, R. N. (1983). Clinical usefulness of estimation of serum fructosamine concentration as a screening test for diabetes mellitus. BMJ. https://doi.org/10.1136/bmj.287.6396.863

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.