Effect of measuring ambulatory blood pressure on sleep and on blood pressure during sleep
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Objective : To assess whether recording of ambulatory blood pressure at night causes arousal from sleep and a change in the continuous blood pressure recorded simultaneously. Design : Repeated measurement of blood pressure with two ambulatory blood pressure machines (Oxford Medical ABP and A&D TM2420) during continuous measurement of beat to beat blood pressure and continuous electroencephalography. Setting : Sleep reseach laboratory. Subjects--Six normal subjects. Main outcome measures : The duration of electroencephalographic arousal and the beat to beat changes in blood pressure produced by the measurement of ambulatory blood pressure; the size of any changes that this arousal and change in blood pressure produced in the blood pressure recorded by the ambulatory machine. Results : Both ambulatory blood pressure machines caused arousal from sleep: the mean duration of arousal was 16 seconds (95% range 0-202) with the ABP and 8 seconds (0-73) with the TM2420. Both also caused a rise in beat to beat blood pressure. During non-rapid eye movement sleep, this rise led to the ABP machine overestimating the true systolic blood pressure during sleep by a mean of 10 (SD 14.8) mm Hg and the TM2420 by a mean of 6.3 (8.2) mm Hg. On average, diastolic pressure was not changed, but measurements in individual subjects changed by up to 23 mm Hg. These changes varied in size among subjects and stages of sleep and were seen after measurements that did not cause any electroencephalographic arousal. Conclusions : Ambulatory blood pressure machines cause appreciable arousal from sleep and therefore alter the blood pressure that they are trying to record. This effect should be taken into account when recordings of blood pressure at night are interpreted in clinical work and epidemiological research.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Parati, G., Casadei, R., Groppelli, A., Di Rienzo, M., & Mancia, G. (1989) · Hypertension · doi:10.1161/01.hyp.13.6.647 · Cited by 899
Cited by
Predictive Role of the Nighttime Blood Pressure
Hansen, T. W., Li, Y., Boggia, J., Thijs, L., Richart, T., & Staessen, J. A. (2011) · Hypertension · doi:10.1161/hypertensionaha.109.133900 · Cited by 597
CPAP and measures of cardiovascular risk in males with OSAS
Kohler, M., Pepperell, J. C. T., Casadei, B., Craig, S., Crosthwaite, N., Stradling, J. R., & Davies, R. J. O. (2008) · European Respiratory Journal · doi:10.1183/09031936.00026608 · Cited by 197
Self-citationTwenty-Four–Hour Ambulatory BP in Snoring Children With Obstructive Sleep Apnea Syndrome
Leung, L. C. K., Ng, D. K., Lau, M. W., Chan, C.-H., Kwok, K.-L., Chow, P.-Y., & Cheung, J. M. Y. (2006) · Chest · doi:10.1016/s0012-3692(15)51134-3 · Cited by 159
Nocturnal blood pressure measured by home devices: evidence and perspective for clinical application
Asayama, K., Fujiwara, T., Hoshide, S., Ohkubo, T., Kario, K., Stergiou, G. S., Parati, G., White, W. B., Weber, M. A., & Imai, Y. (2019) · Journal of Hypertension · doi:10.1097/hjh.0000000000001987 · Cited by 120
Repetitive exposure to shortened sleep leads to blunted sleep-associated blood pressure dipping
Yang, H., Haack, M., Gautam, S., Meier-Ewert, H. K., & Mullington, J. M. (2017) · Journal of Hypertension · doi:10.1097/hjh.0000000000001284 · Cited by 69
“The Portapres produces less noise and tactile stimuli than ambulatory arm measurement devices [30] and was chosen for its minimal sleep disruption.”
Metadata
- Authors
- Davies, R. J. O., Jenkins, N. E., & Stradling, J. R.
- Venue
- BMJ
- Publisher
- BMJ
- Published
- 1994-03-26
- Volume
- 308
- Issue
- 6932
- Pages
- 820-823
- ISSN
- 0007-1447 (ISSN-L)
- 0959-8138
- 1468-5833
- OpenAlex
- W1991029547
- Cited by
- 116
- References
- 1
- FWCI
- 4.79
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.