The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Reducing errors made by emergency physicians in interpreting radiographs: longitudinal study
Open accessAbstract
OBJECTIVES: To reduce errors made in the interpretation of radiographs in an emergency department. DESIGN: Longitudinal study. SETTING: Hospital emergency department. INTERVENTIONS: All staff reviewed all clinically significant discrepancies at monthly meetings. A file of clinically significant errors was created; the file was used for teaching. Later a team redesigned the process. A system was developed for interpreting radiographs that would be followed regardless of the day of the week or time of day. All standard radiographs were brought directly to the emergency physician for immediate interpretation. Radiologists reviewed the films within 12 hours as a quality control measure, and if a significant misinterpretation was found patients were asked to return. MAIN OUTCOME MEASURES: Reduction in number of clinically significant errors (such as missed fractures or foreign bodies) on radiographs read in the emergency department. Data on the error rate for radiologists and the effect of the recall procedure were not available so reliability modelling was used to assess the effect of these on overall safety. RESULTS: After the initial improvements the rate of false negative errors fell from 3% (95% confidence interval 2.8% to 3.2%) to 1.2% (1.03% to 1.37%). After the processes were redesigned it fell further to 0.3% (0.26% to 0.34%). Reliability modelling showed that the number of potential adverse effects per 1000 cases fell from 19 before the improvements to 3 afterwards and unmitigated adverse effects fell from 2.2/1000 before to 0.16/1000 afterwards, assuming 95% success in calling patients back. CONCLUSION: Systems of radiograph interpretation that optimise the skills of all clinicians involved and contain reliable processes for mitigating errors can reduce error rates substantially.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A primer on leading the improvement of systems: Fig 1
Berwick, D. M. (1996) · BMJ · doi:10.1136/bmj.312.7031.619 · Cited by 793
Cited by
Assessing the quality of controlled clinical trials
Jüni, P., Altman, D. G., & Egger, M. (2001) · BMJ · doi:10.1136/bmj.323.7303.42 · Cited by 3,309
Overconfidence as a Cause of Diagnostic Error in Medicine
Berner, E. S., & Graber, M. L. (2008) · The American Journal of Medicine · doi:10.1016/j.amjmed.2008.01.001 · Cited by 1,034
Deep neural network improves fracture detection by clinicians
Lindsey, R., Daluiski, A., Chopra, S., Lachapelle, A., Mozer, M., Sicular, S., Hanel, D., Gardner, M., Gupta, A., Hotchkiss, R., et al. (2018) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1806905115 · Cited by 640
Kachalia, A., Gandhi, T. K., Puopolo, A. L., Yoon, C., Thomas, E. J., Griffey, R., Brennan, T. A., & Studdert, D. M. (2007) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2006.06.035 · Cited by 497
A review of evidence of health benefit from artificial neural networks in medical intervention
Lisboa, P. J. G. (2002) · Neural Networks · doi:10.1016/s0893-6080(01)00111-3 · Cited by 458
Metadata
- Authors
- Espinosa, J. A.
- Venue
- BMJ
- Publisher
- BMJ
- Published
- 2000-03-18
- Volume
- 320
- Issue
- 7237
- Pages
- 737-740
- ISSN
- 0959-8138 (ISSN-L)
- OpenAlex
- W2131625997
- Cited by
- 160
- References
- 1
- FWCI
- 9.78
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reducing errors made by emergency physicians in interpreting radiographs: longitudinal study. https://app.cochat.ai/papers/10.1136/bmj.320.7237.737
- The paper
- Espinosa, J. A. (2000). Reducing errors made by emergency physicians in interpreting radiographs: longitudinal study. BMJ. https://doi.org/10.1136/bmj.320.7237.737
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.