Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 306

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Blood pressure measurement: Part II—Conventional sphygmomanometry: technique of auscultatory blood pressure measurement

Open access
Beevers, Gareth, Lip, Gregory Y H, O'Brien, Eoin · 2001 · BMJ

Abstract

The measurement of blood pressure in clinical practice by the century-old technique of Riva-Rocci/Korotkoff is dependent on the accurate transmission and interpretation of a signal (Korotkoff sound or pulse wave) from a subject via a device (the sphygmomanometer) to an observer. Errors in measurement can occur at each of these interactionary points of the technique, but by far the most fallible component is the observer. #### Rose classification of observer error In 1964, Geoffrey Rose and his colleagues classified observer error into three categories.1 #### Observer training techniques ### Systematic error This leads to both intraobserver and interobserver error. It may be caused by lack of concentration, poor hearing, confusion of auditory and visual cues, etc. The most important factor is failure to interpret the Korotkoff sounds accurately, especially for diastolic pressure. ### Terminal digit preference This refers to the phenomenon whereby the observer rounds off the pressure reading to a digit of his or her choosing, most often to zero. Doctors may have a 12-fold bias in favour of the terminal digit zero; this has grave implications for decisions on diagnosis and treatment, although its greatest effect is in epidemiological and research studies in which it can distort the frequency distribution curve and reduce the power of statistical tests.2 ### Observer prejudice or bias This is the practice whereby the observer simply adjusts the pressure to meet his or her preconceived notion of what the pressure should be. It usually occurs when there has been recording of an excess of pressures below the cut-off point for hypertension and it reflects the observer's reluctance to diagnose hypertension. This is most likely to occur when an arbitrary division is applied between normal and high blood pressure, for example 140/90 mm Hg. An observer might tend to record a …

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/bmj.322.7293.1043

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 306

Metadata

Authors
Beevers, G., Lip, G. Y. H., & O'Brien, E.
Venue
BMJ
Publisher
BMJ
Published
2001-04-28
Volume
322
Issue
7293
Pages
1043-1047
ISSN
  • 0007-1447 (ISSN-L)
  • 0959-8138
  • 1468-5833
OpenAlex
W2754806877
Cited by
306
References
8
FWCI
9.75
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Blood pressure measurement: Part II—Conventional sphygmomanometry: technique of auscultatory blood pressure measurement. https://app.cochat.ai/papers/10.1136/bmj.322.7293.1043
The paper
Beevers, G., Lip, G. Y. H., & O'Brien, E. (2001). Blood pressure measurement: Part II—Conventional sphygmomanometry: technique of auscultatory blood pressure measurement. BMJ. https://doi.org/10.1136/bmj.322.7293.1043

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.