Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 257

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

NICE's cost effectiveness threshold

Open access
Appleby, John, Devlin, Nancy, Parkin, David · 2007 · BMJ

Abstract

Diagnosing atrial fibrillation in general practiceThe combination of a clinical history, clinical signs, and an ECG will pick up most casesIn this week's BMJ, Mant and colleagues and Fitzmaurice and colleagues present the results of the SAFE (screening for atrial fibrillation in the elderly) study.They assess how accurately general practitioners, practice nurses, and an interpretive computer program can diagnose atrial fibrillation on an electrocardiogram (ECG), and they report on the effectiveness of screening patients aged 65 and over for atrial fibrillation in British general practice.1 2 The prevalence of atrial fibrillation rises with age from 1.5% in people in their 60s to more than 10% in those over 90.People with atrial fibrillation have double the mortality and a four to fivefold higher risk of stroke than those without fibrillation.About a quarter of all strokes in elderly people are caused by atrial fibrillation.Strokes caused by atrial fibrillation are often severe and lead to high mortality and a low quality of life.3 Even if normal rhythm cannot be restored, antiplatelet agents reduce the risk of stroke by around 22% and vitamin K antagonists, such as warfarin, reduce the risk by 64% (number needed to treat for one year 37, for patients who have already had a transient ischaemic attack or stroke 12). 4 Thus, diagnosing atrial fibrillation is worthwhile, because effective interventions are available.However, intervention is not without risk and often requires lifelong drug treatment.Therefore, a diagnosis must be made on objective criteria.The 12 lead ECG is the reference standard, but interpretation can be difficult and misinterpretations often occur.5 The study by Mant and colleagues assesses the accuracy of 49 general practitioners, 49 practice nurses, and interpretative software in diagnosing atrial fibrillation on ECG, without any clinical information.1 Sensitivity was around 80% in all three groups, but specificity was lower in nurses (85%) and general practitioners (92%) than with the software (99%).Because all three methods failed to diagnose about 20% of patients, none seems appropriate for screening purposes.A further disappointment was that training had little effect on the ability to interpret the ECGs correctly.Fortunately, one lead ECGs were as sensitive as 12 lead ECGs, and agreement between the two cardiologists who were the reference standard was very high.The logical conclusion is that a one lead ECG (which saves time and permits the use of loop recorders in daily practice) is sufficient for diagnosis, and that an experienced cardiologist should interpret the ECG.Another small study in general practice has shown that an experienced nurse and general practitioner could diagnose atrial fibrillation on ECGs with a sensitivity of 96% and 100% and a specificity of 93% and 98%, respectively.6 However, only one experienced nurse spl

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/bmj.39308.560069.be

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 257

Metadata

Authors
Appleby, J., Devlin, N., & Parkin, D.
Venue
BMJ
Publisher
BMJ
Published
2007-08-23
Volume
335
Issue
7616
Pages
358-359
ISSN
  • 0007-1447 (ISSN-L)
  • 0959-8138
  • 1468-5833
OpenAlex
W1976812315
Cited by
257
References
4
FWCI
10.80
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: NICE's cost effectiveness threshold. https://app.cochat.ai/papers/10.1136/bmj.39308.560069.be
The paper
Appleby, J., Devlin, N., & Parkin, D. (2007). NICE's cost effectiveness threshold. BMJ. https://doi.org/10.1136/bmj.39308.560069.be

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.