Routine care of peripheral intravenous catheters versus clinically indicated replacement: randomised controlled trial
Open accessAbstract
OBJECTIVE: To compare routine replacement of intravenous peripheral catheters with replacement only when clinically indicated. DESIGN: Randomised controlled trial. SETTING: Tertiary hospital in Australia. PARTICIPANTS: 755 medical and surgical patients: 379 allocated to catheter replacement only when clinically indicated and 376 allocated to routine care of catheter (control group). MAIN OUTCOME MEASURE: A composite measure of catheter failure resulting from phlebitis or infiltration. RESULTS: Catheters were removed because of phlebitis or infiltration from 123 of 376 (33%) patients in the control group compared with 143 of 379 (38%) patients in the intervention group; the difference was not significant (relative risk 1.15, 95% confidence interval 0.95 to 1.40). When the analysis was based on failure per 1000 device days (number of failures divided by number of days catheterised, divided by 1000), no difference could be detected between the groups (relative risk 0.98, 0.78 to 1.24). Infusion related costs were higher in the control group (mean $A41.02; pound19.71; euro24.80; $38.55) than intervention group ($A36.40). The rate of phlebitis in both groups was low (4% in intervention group, 3% in control group). CONCLUSION: Replacing peripheral intravenous catheters when clinically indicated has no effect on the incidence of failure, based on a composite measure of phlebitis or infiltration. Larger trials are needed to test this finding using phlebitis alone as a more clinically meaningful outcome. REGISTRATION NUMBER: Australian New Zealand Clinical Trials Registry ACTRN12605000147684.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Moher, D., Schulz, K. F., & Altman, D. G. (2001) · BMC Medical Research Methodology · doi:10.1186/1471-2288-1-2 · Cited by 2,755
Moher, D., Schulz, K. F., Altman, D. G., & for the CONSORT Group* (2001) · Annals of Internal Medicine · doi:10.7326/0003-4819-134-8-200104170-00011 · Cited by 1,426
Cited by
Moher, D., Hopewell, S., Schulz, K. F., Montori, V., Gotzsche, P. C., Devereaux, P. J., Elbourne, D., Egger, M., & Altman, D. G. (2010) · BMJ · doi:10.1136/bmj.c869 · Cited by 8,883
Guidelines for the Prevention of Intravascular Catheter-related Infections
O'Grady, N. P., Alexander, M., Burns, L. A., Dellinger, E. P., Garland, J., Heard, S. O., Lipsett, P. A., Masur, H., Mermel, L. A., Pearson, M. L., et al. (2011) · Clinical Infectious Diseases · doi:10.1093/cid/cir257 · Cited by 4,699
Moher, D., Hopewell, S., Schulz, K. F., Montori, V., Gøtzsche, P. C., Devereaux, P. J., Elbourne, D., Egger, M., & Altman, D. G. (2012) · International Journal of Surgery · doi:10.1016/j.ijsu.2011.10.001 · Cited by 2,345
Moher, D., Hopewell, S., Schulz, K. F., Montori, V., Gøtzsche, P. C., Devereaux, P. J., Elbourne, D., Egger, M., & Altman, D. G. (2010) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2010.03.004 · Cited by 1,858
Guidelines for the prevention of intravascular catheter-related infections
O'Grady, N. P., Alexander, M., Burns, L. A., Dellinger, E. P., Garland, J., Heard, S. O., Lipsett, P. A., Masur, H., Mermel, L. A., Pearson, M. L., et al. (2011) · American Journal of Infection Control · doi:10.1016/j.ajic.2011.01.003 · Cited by 1,066
Metadata
- Authors
- Webster, J., Clarke, S., Paterson, D., Hutton, A., Dyk, S. V., Gale, C., & Hopkins, T.
- Venue
- BMJ
- Publisher
- BMJ
- Published
- 2008-07-08
- Volume
- 337
- Issue
- jul08 1
- Pages
- a339-a339
- ISSN
- 0007-1447 (ISSN-L)
- 0959-8138
- 1468-5833
- OpenAlex
- W2057185077
- Cited by
- 190
- References
- 2
- FWCI
- 15.93
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Routine care of peripheral intravenous catheters versus clinically indicated replacement: randomised controlled trial. https://app.cochat.ai/papers/10.1136/bmj.a339
- The paper
- Webster, J., Clarke, S., Paterson, D., Hutton, A., Dyk, S. V., Gale, C., & Hopkins, T. (2008). Routine care of peripheral intravenous catheters versus clinically indicated replacement: randomised controlled trial. BMJ. https://doi.org/10.1136/bmj.a339
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.