The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Imaging strategies for detection of urgent conditions in patients with acute abdominal pain: diagnostic accuracy study
Open accessAbstract
OBJECTIVE: To identify an optimal imaging strategy for the accurate detection of urgent conditions in patients with acute abdominal pain. DESIGN: Fully paired multicentre diagnostic accuracy study with prospective data collection. SETTING: Emergency departments of two university hospitals and four large teaching hospitals in the Netherlands. PARTICIPANTS: 1021 patients with non-traumatic abdominal pain of >2 hours' and <5 days' duration. Exclusion criteria were discharge from the emergency department with no imaging considered warranted by the treating physician, pregnancy, and haemorrhagic shock. INTERVENTION: All patients had plain radiographs (upright chest and supine abdominal), ultrasonography, and computed tomography (CT) after clinical and laboratory examination. A panel of experienced physicians assigned a final diagnosis after six months and classified the condition as urgent or non-urgent. MAIN OUTCOME MEASURES: Sensitivity and specificity for urgent conditions, percentage of missed cases and false positives, and exposure to radiation for single imaging strategies, conditional imaging strategies (CT after initial ultrasonography), and strategies driven by body mass index and age or by location of pain. RESULTS: 661 (65%) patients had a final diagnosis classified as urgent. The initial clinical diagnosis resulted in many false positive urgent diagnoses, which were significantly reduced after ultrasonography or CT. CT detected more urgent diagnoses than did ultrasonography: sensitivity was 89% (95% confidence interval 87% to 92%) for CT and 70% (67% to 74%) for ultrasonography (P<0.001). A conditional strategy with CT only after negative or inconclusive ultrasonography yielded the highest sensitivity, missing only 6% of urgent cases. With this strategy, only 49% (46% to 52%) of patients would have CT. Alternative strategies guided by body mass index, age, or location of the pain would all result in a loss of sensitivity. CONCLUSION: Although CT is the most sensitive imaging investigation for detecting urgent conditions in patients with abdominal pain, using ultrasonography first and CT only in those with negative or inconclusive ultrasonography results in the best sensitivity and lowers exposure to radiation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Computed Tomography — An Increasing Source of Radiation Exposure
Brenner, D. J., & Hall, E. J. (2007) · New England Journal of Medicine · doi:10.1056/nejmra072149 · Cited by 8,748
Recommendations of the International Commission on Radiological Protection
(1961) · Postgraduate Medical Journal · doi:10.1136/pgmj.37.425.168-b · Cited by 5,862
Health Risks from Exposure to Low Levels of Ionizing Radiation:: BEIR VII Phase 2
Earth, D. O. (2006) · CERN Document Server (European Organization for Nuclear Research) · Cited by 2,190
Recommendations of the International Commission on Radiological Protection, ICRP Publication 26
Icrp (1977) · Annals of the ICRP · Cited by 1,780
Benefits and costs, an eternal balance
Dixon, A. K. (2007) · Annals of the ICRP · doi:10.1016/j.icrp.2007.09.001 · Cited by 1,355
Effect of Computed Tomography of the Appendix on Treatment of Patients and Use of Hospital Resources
Rao, P. M., Rhea, J. T., Novelline, R. A., Mostafavi, A. A., & McCabe, C. J. (1998) · New England Journal of Medicine · doi:10.1056/nejm199801153380301 · Cited by 711
Increasing utilization of computed tomography in the adult emergency department, 2000–2005
Broder, J., & Warshauer, D. M. (2006) · Emergency Radiology · doi:10.1007/s10140-006-0493-9 · Cited by 478
Ng, C. S., Watson, C. J. E., Palmer, C. R., See, T. C., Beharry, N., Housden, B. A., Bradley, J. A., & Dixon, A. K. (2002) · BMJ · doi:10.1136/bmj.325.7377.1387 · Cited by 175
Golash, V., & Willson, P. D. (2005) · Surgical Endoscopy · doi:10.1007/s00464-004-8866-1 · Cited by 172
Assessing the gain in diagnostic performance when combining two diagnostic tests
Macaskill, P., Walter, S. D., Irwig, L., & Franco, E. L. (2002) · Statistics in Medicine · doi:10.1002/sim.1227 · Cited by 98
Cited by
Guidelines of Diagnostics and Treatment of Acute Left-Sided Colonic Diverticulitis
Andeweg, C. S., Mulder, I. M., Felt-Bersma, R. J. F., Verbon, A., van der Wilt, G. J., van Goor, H., Lange, J. F., Stoker, J., Boermeester, M. A., & Bleichrodt, R. P. (2013) · Digestive Surgery · doi:10.1159/000354035 · Cited by 844
Self-citationPanes, J., Bouhnik, Y., Reinisch, W., Stoker, J., Taylor, S. A., Baumgart, D. C., Danese, S., Halligan, S., Marincek, B., Matos, C., et al. (2013) · Journal of Crohn's and Colitis · doi:10.1016/j.crohns.2013.02.020 · Cited by 668
Self-citationA comprehensive review and update on Crohn's disease
Gajendran, M., Loganathan, P., Catinella, A. P., & Hashash, J. G. (2018) · Disease-a-Month · doi:10.1016/j.disamonth.2017.07.001 · Cited by 550
Imaging Patients with Acute Abdominal Pain
Stoker, J., van Randen, A., Laméris, W., & Boermeester, M. A. (2009) · Radiology · doi:10.1148/radiol.2531090302 · Cited by 431
Self-citationSartelli, M., Weber, D. G., Kluger, Y., Ansaloni, L., Coccolini, F., Abu-Zidan, F., Augustin, G., Ben-Ishay, O., Biffl, W. L., Bouliaris, K., et al. (2020) · World Journal of Emergency Surgery · doi:10.1186/s13017-020-00313-4 · Cited by 400
A Systematic Review and Meta-Analysis of Diagnostic Performance of Imaging in Acute Cholecystitis
Kiewiet, J. J. S., Leeuwenburgh, M. M. N., Bipat, S., Bossuyt, P. M. M., Stoker, J., & Boermeester, M. A. (2012) · Radiology · doi:10.1148/radiol.12111561 · Cited by 329
Self-citationCervellin, G., Mora, R., Ticinesi, A., Meschi, T., Comelli, I., Catena, F., & Lippi, G. (2016) · Annals of Translational Medicine · doi:10.21037/atm.2016.09.10 · Cited by 316
on behalf of the OPTIMA study group, van Randen, A., Laméris, W., van Es, H. W., van Heesewijk, H. P. M., van Ramshorst, B., ten Hove, W., Bouma, W. H., van Leeuwen, M. S., van Keulen, E. M., et al. (2011) · European Radiology · doi:10.1007/s00330-011-2087-5 · Cited by 300
Self-citationWSES/GAIS/SIS-E/WSIS/AAST global clinical pathways for patients with intra-abdominal infections
Sartelli, M., Coccolini, F., Kluger, Y., Agastra, E., Abu-Zidan, F. M., Abbas, A. E. S., Ansaloni, L., Adesunkanmi, A. K., Atanasov, B., Augustin, G., et al. (2021) · World Journal of Emergency Surgery · doi:10.1186/s13017-021-00387-8 · Cited by 207
“In order to identify an optimal imaging strategy for the accurate detection of urgent conditions in patients with acute abdominal pain, a multicenter diagnostic accuracy study using prospective data collection has been published [18].”
BackgroundSelf-citationIndications for abdominal imaging: when and what to choose?
Department of Medical Imaging, “. H. U. O. M. A. P., Caraiani, C., Yi, D., Department of Ultrasound, Z. H., Petresc, B., Department of Medical Imaging, “. H. U. O. M. A. P., Dietrich, C., & Department Allgemeine Innere Medizin, K. H. B. B. S. (2020) · Journal of Ultrasonography · doi:10.15557/jou.2020.0008 · Cited by 66
Metadata
- Authors
- Lameris, W., van Randen, A., van Es, H. W., van Heesewijk, J. P. M., van Ramshorst, B., Bouma, W. H., ten Hove, W., van Leeuwen, M. S., van Keulen, E. M., Dijkgraaf, M. G. W., Bossuyt, P. M. M., Boermeester, M. A., Stoker, J., & on behalf of the OPTIMA study group
- Venue
- BMJ
- Publisher
- BMJ
- Published
- 2009-06-26
- Volume
- 338
- Issue
- jun26 2
- Pages
- b2431-b2431
- ISSN
- 0007-1447 (ISSN-L)
- 0959-8138
- 1468-5833
- OpenAlex
- W2142007213
- Cited by
- 416
- References
- 13
- FWCI
- 13.77
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.