Low intensity pulsed ultrasonography for fractures: systematic review of randomised controlled trials
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To determine the efficacy of low intensity pulsed ultrasonography for healing of fractures. DESIGN: Systematic review of randomised controlled trials. DATA SOURCES: Electronic literature search without language restrictions of CINAHL, Embase, Medline, HealthSTAR, and the Cochrane Central Registry of Controlled Trials, from inception of the database to 10 September 2008. Review methods Eligible studies were randomised controlled trials that enrolled patients with any kind of fracture and randomly assigned them to low intensity pulsed ultrasonography or to a control group. Two reviewers independently agreed on eligibility; three reviewers independently assessed methodological quality and extracted outcome data. All outcomes were included and meta-analyses done when possible. RESULTS: 13 randomised trials, of which five assessed outcomes of importance to patients, were included. Moderate quality evidence from one trial found no effect of low intensity pulsed ultrasonography on functional recovery from conservatively managed fresh clavicle fractures; whereas low quality evidence from three trials suggests benefit in non-operatively managed fresh fractures (faster radiographic healing time mean 36.9%, 95% confidence interval 25.6% to 46.0%). A single trial provided moderate quality evidence suggesting no effect of low intensity pulsed ultrasonography on return to function among non-operatively treated stress fractures. Three trials provided very low quality evidence for accelerated functional improvement after distraction osteogenesis. One trial provided low quality evidence for a benefit of low intensity pulsed ultrasonography in accelerating healing of established non-unions managed with bone graft. Four trials provided low quality evidence for acceleration of healing of operatively managed fresh fractures. CONCLUSION: Evidence for the effect of low intensity pulsed ultrasonography on healing of fractures is moderate to very low in quality and provides conflicting results. Although overall results are promising, establishing the role of low intensity pulsed ultrasonography in the management of fractures requires large, blinded trials, directly addressing patient important outcomes such as return to function.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Interaction revisited: the difference between two estimates.
Altman, D. G., & Bland, J. M. (2003) · BMJ · doi:10.1136/bmj.326.7382.219 · Cited by 3,203
Chan, A.-W., Hróbjartsson, A., Haahr, M. T., Gøtzsche, P. C., & Altman, D. G. (2004) · JAMA · doi:10.1001/jama.291.20.2457 · Cited by 1,845 · cited 1×
“and the inconsistent reporting of outcomes across trials raises the possibility of selective reporting bias,”
BackgroundGrading Strength of Recommendations and Quality of Evidence in Clinical Guidelines
Guyatt, G., Gutterman, D., Baumann, M. H., Addrizzo-Harris, D., Hylek, E. M., Phillips, B., Raskob, G., Lewis, S. Z., & Schünemann, H. (2006) · Chest · doi:10.1378/chest.129.1.174 · Cited by 1,220 · cited 1×
“Overall, 564 potentially eligible studies were identified and 18 retrieved in full text.”
BackgroundSelf-citationPogue, J. M., & Yusuf, S. (1997) · Controlled Clinical Trials · doi:10.1016/s0197-2456(97)00051-2 · Cited by 415 · cited 1×
“Meta-analyses of small trials can provide evidence of benefit with what seem to be narrow estimates of precision; however, such reviews have often been subsequently refuted by large trials. To address this potential concern we determined that in cases in which our meta-analysis suggested benefit with an associated nar…”
ResultBOUTRON, I., MOHER, D., TUGWELL, P., GIRAUDEAU, B., POIRAUDEAU, S., NIZARD, R., & RAVAUD, P. (2005) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2005.05.004 · Cited by 308
Cited by
Fracture healing: mechanisms and interventions
Einhorn, T. A., & Gerstenfeld, L. C. (2015) · Nature Reviews Rheumatology · doi:10.1038/nrrheum.2014.164 · Cited by 1,807
GRADE guidelines: 12. Preparing Summary of Findings tables—binary outcomes
Guyatt, G. H., Oxman, A. D., Santesso, N., Helfand, M., Vist, G., Kunz, R., Brozek, J., Norris, S., Meerpohl, J., Djulbegovic, B., et al. (2013) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2012.01.012 · Cited by 836
“Here, the review authors address the effect of low-intensity, pulsed, ultrasound on fracture healing [16].”
BackgroundSelf-citationSchünemann, H. J., Wiercioch, W., Brozek, J., Etxeandia-Ikobaltzeta, I., Mustafa, R. A., Manja, V., Brignardello-Petersen, R., Neumann, I., Falavigna, M., Alhazzani, W., et al. (2017) · Journal of Clinical Epidemiology · doi:10.1016/j.jclinepi.2016.09.009 · Cited by 645
Stimulation of bone repair with ultrasound: A review of the possible mechanic effects
Padilla, F., Puts, R., Vico, L., & Raum, K. (2014) · Ultrasonics · doi:10.1016/j.ultras.2014.01.004 · Cited by 234
“), suggesting the need for standardization of treatment dose and for further randomized controlled trials [12,1,13,14].”
BackgroundLeighton, R., Watson, J. T., Giannoudis, P., Papakostidis, C., Harrison, A., & Steen, R. G. (2017) · Injury · doi:10.1016/j.injury.2017.05.016 · Cited by 162
Metadata
- Authors
- Busse, J. W., Kaur, J., Mollon, B., Bhandari, M., Tornetta, P., Schunemann, H. J., & Guyatt, G. H.
- Venue
- BMJ
- Publisher
- BMJ
- Published
- 2009-02-27
- Volume
- 338
- Issue
- feb27 1
- Pages
- b351-b351
- ISSN
- 0007-1447 (ISSN-L)
- 0959-8138
- 1468-5833
- OpenAlex
- W2095813564
- Cited by
- 134
- References
- 5
- FWCI
- 1.62
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.