CoChat

Limits of agreement (Bland-Altman method)

Sedgwick, P. · 2013 · BMJ
Cited by 104

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Researchers investigated the agreement between primary care and daytime ambulatory monitoring in blood pressure measurement. Study participants were patients with newly diagnosed high or borderline high blood pressure or those receiving treatment for hypertension but with poor control. In total, 179 patients were recruited from three general practices, and eight doctors were involved in measuring blood pressure. Daytime ambulatory monitoring was undertaken between 0700 and 2300 hours.1 A significant correlation was found between the systolic blood pressure measured by the general practitioner and daytime ambulatory systolic pressure ( r =0.46; P<0.05). The measurements made by the doctors exceeded those obtained by ambulatory monitoring by an average of 18.9 mm Hg. The Bland-Altman method was used to plot the difference in systolic blood pressure for each patient (GP measurement minus daytime ambulatory monitoring measurement) against the mean of the two measurements (fig 1⇓). The limits of agreement are indicated by the red broken lines—that is, the interval of two standard deviations of the measurement differences either side of the mean difference. Fig 1 Bland-Altman plot of difference in systolic blood pressure (general practitioner measurement minus daytime ambulatory monitoring measurement) against the mean of the two measurements Which of the following statements, if any, are true?

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/bmj.f1630

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 104

Metadata

Authors
Sedgwick, P.
Venue
BMJ
Publisher
BMJ
Published
2013-03-15
Volume
346
Issue
mar15 1
Pages
f1630-f1630
ISSN
1756-1833 (ISSN-L)
OpenAlex
W2021596595
Cited by
104
References
1
FWCI
5.93
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.