Accuracy of 2 Activity Monitors in Detecting Steps in People With Stroke and Traumatic Brain Injury
Abstract
Background: Advances in sensor technologies and signal processing techniques provide a method to accurately measure walking activity in the home and community. Activity monitors geared toward consumer or patient use may be an alternative to more expensive monitors designed for research to measure stepping activity. Objective: The objective of this study was to examine the accuracy of 2 consumer/patient activity monitors, the Fitbit Ultra and the Nike+ Fuelband, in identifying stepping activity in people with stroke and traumatic brain injury (TBI). Secondarily, the study sought to compare the accuracy of these 2 activity monitors with that of the StepWatch Activity Monitor (SAM) and a pedometer, the Yamax Digi-Walker SW-701 pedometer (YDWP). Design: A cross-sectional design was used for this study. Method: People with chronic stroke and TBI wore the 4 activity monitors while they performed the Two-Minute Walk Test (2MWT), during which they were videotaped. Activity monitor estimated steps taken were compared with actual steps taken counted from videotape. Accuracy and agreement between activity monitor estimated steps and actual steps were examined using intraclass correlation coefficients (ICC [2,1]) and the Bland-Altman method. Results: The SAM demonstrated the greatest accuracy (ICC [2,1]=.97, mean difference between actual steps and SAM estimated steps=4.7 steps) followed by the Fitbit Ultra (ICC [2,1]=.73, mean difference between actual steps and Fitbit Ultra estimated steps=−9.7 steps), the YDWP (ICC [2,1]=.42, mean difference between actual steps and YDWP estimated steps=−28.8 steps), and the Nike+ Fuelband (ICC [2,1]=.20, mean difference between actual steps and Nike+ Fuelband estimated steps=−66.2 steps). Limitations: Walking activity was measured over a short distance in a closed environment, and participants were high functioning ambulators, with a mean gait speed of 0.93 m/s. Conclusions: The Fitbit Ultra may be a low-cost alternative to measure the stepping activity in level, predictable environments of people with stroke and TBI who can walk at speeds ≥0.58 m/s.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In stroke, good agreement was found between step counts derived from wearables compared to step counts from 3D gait analysis or video-based counts.
“In stroke, good agreement was found between step counts derived from wearables compared to step counts from 3D gait analysis [53] or video-based counts [54].”
From Wearable sensors for clinical applications in epilepsy, Parkinson’s disease, and stroke: A mixed-methods systematic review (2018) · cites this paper as [54]
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965 · see citing works
Intraclass correlations: Uses in assessing rater reliability.
Shrout, P. E., & Fleiss, J. L. (1979) · Psychological Bulletin · doi:10.1037/0033-2909.86.2.420 · Cited by 23,433 · see citing works
Beckett, A. H., Rowland, M., & TURNER, P. (1965) · The Lancet · doi:10.1016/s0140-6736(65)91037-8 · Cited by 16,917 · see citing works
Practical Statistics for Medical Research.
Walter, S., & Altman, D. G. (1992) · Biometrics · doi:10.2307/2532320 · Cited by 11,665 · see citing works
Practical Statistics for Medical Research
Altman, D. G. (1990) · doi:10.1201/9780429258589 · Cited by 10,668 · see citing works
Using Pedometers to Increase Physical Activity and Improve Health: A Systematic Review
Bravata, D. M., Smith-Spangler, C., Sundaram, V., Gienger, A. L., Lin, N., Lewis, R., Stave, C. D., Olkin, I., & Sirard, J. R. (2007) · JAMA · doi:10.1001/jama.298.19.2296 · Cited by 2,064 · see citing works
Classification of Walking Handicap in the Stroke Population
Perry, J., Garrett, M., Gronley, J. K., & Mulroy, S. J. (1995) · Stroke · doi:10.1161/01.str.26.6.982 · Cited by 1,560 · see citing works
Usefulness of the Berg Balance Scale in Stroke Rehabilitation: A Systematic Review
Blum, L. M., & Korner-Bitensky, N. A. (2008) · Physical Therapy · doi:10.2522/ptj.20070205 · Cited by 1,211 · see citing works
The Technology of Accelerometry-Based Activity Monitors: Current and Future
CHEN, K. Y., & BASSETT, D. R. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185571.49104.82 · Cited by 996 · see citing works
Practical Statistics for Medical Research
Newcombe, R. G. (1992) · Journal of Epidemiology & Community Health · doi:10.1136/jech.46.5.549-a · Cited by 991 · see citing works
Machine Learning Methods for Classifying Human Physical Activity from On-Body Accelerometers
Mannini, A., & Sabatini, A. M. (2010) · Sensors · doi:10.3390/s100201154 · Cited by 785 · see citing works
Lord, S. E., McPherson, K. M., McNaughton, H., Rochester, L., & Weatherall, M. (2004) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2003.05.002 · Cited by 698 · see citing works
Improvements in Speed-Based Gait Classifications Are Meaningful
Schmid, A. A., Duncan, P. W., Studenski, S. A., Lai, S. M., Richards, L. G., Perera, S., & Wu, S. S. (2007) · Stroke · doi:10.1161/strokeaha.106.475921 · Cited by 655 · see citing works
How to Assess the Reliability of Measurements in Rehabilitation
Lexell, J. E., & Downham, D. Y. (2005) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/01.phm.0000176452.17771.20 · Cited by 629 · see citing works
Tudor-Locke, C. E., & Myers, A. M. (2001) · Research Quarterly for Exercise and Sport · doi:10.1080/02701367.2001.10608926 · Cited by 518 · see citing works
The validity and reliability of a novel activity monitor as a measure of walking
Ryan, C. G., Grant, P., Tigbe, W. W., & Granat, M. H. (2006) · British Journal of Sports Medicine · doi:10.1136/bjsm.2006.027276 · Cited by 490 · see citing works
Rehabilitation goals of patients with hemiplegia
Bohannon, R. W., Andrews, A. W., & Smith, M. B. (1988) · International Journal of Rehabilitation Research · doi:10.1097/00004356-198806000-00012 · Cited by 396 · see citing works
Some common problems in medical research
Altman, D. (1999) · Medical Entomology and Zoology · Cited by 339 · see citing works
Dobkin, B. H., & Dorsch, A. K. (2011) · Neurorehabilitation and neural repair · doi:10.1177/1545968311425908 · Cited by 295 · see citing works
Monitoring of Physical Activity after Stroke: A Systematic Review of Accelerometry-Based Measures
Gebruers, N., Vanroy, C., Truijen, S., Engelborghs, S., & De Deyn, P. P. (2010) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2009.10.025 · Cited by 293 · see citing works
Sensors-Based Wearable Systems for Monitoring of Human Movement and Falls
Shany, T., Redmond, S. J., Narayanan, M. R., & Lovell, N. H. (2011) · IEEE Sensors Journal · doi:10.1109/jsen.2011.2146246 · Cited by 286 · see citing works
Taraldsen, K., Askim, T., Sletvold, O., Einarsen, E. K., Bjåstad, K. G., Indredavik, B., & Helbostad, J. L. (2011) · Physical Therapy · doi:10.2522/ptj.20100159 · Cited by 282 · see citing works
Fulk, G. D., & Echternach, J. L. (2008) · Neurology Report · doi:10.1097/npt0b013e31816593c0 · Cited by 235 · see citing works
Self-citationMeasurement of Community Ambulation After Stroke
Lord, S. E., & Rochester, L. (2005) · Stroke · doi:10.1161/01.str.0000170698.20376.2e · Cited by 231 · see citing works
Motion Sensor Accuracy under Controlled and Free-Living Conditions
Masurier, G. C. L., Lee, S. M., & Tudor-Locke, C. E. (2004) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000126777.50188.73 · Cited by 229 · see citing works
Cardiovascular Health and Fitness After Stroke
Ivey, F. M., Macko, R. F., Ryan, A. S., & Hafer‐Macko, C. E. (2005) · Topics in Stroke Rehabilitation · doi:10.1310/geeu-yruy-vj72-lear · Cited by 226 · see citing works
SROKE RECOVERY: HE CAN BUT DOES HE?
Andrews, K. L., & Steward, J. (1979) · Lara D. Veeken · doi:10.1093/rheumatology/18.1.43 · Cited by 201 · see citing works
Shuger, S. L., Barry, V., Sui, X., McClain, A. C., Hand, G. A., Wilcox, S., Meriwether, R. A., Hardin, J. W., & Blair, S. N. (2011) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/1479-5868-8-41 · Cited by 199 · see citing works
Microprocessor-based ambulatory activity monitoring in stroke patients
Macko, R. F., Haeuber, E., Shaughnessy, M., Coleman, K. L., Boone, D. A., Smith, G. V., & Silver, K. H. C. (2002) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200203000-00002 · Cited by 185 · see citing works
Haeuber, E., Shaughnessy, M., Forrester, L. W., Coleman, K. L., & Macko, R. F. (2004) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2003.11.035 · Cited by 182 · see citing works
Evaluation of Activity Monitors in Controlled and Free-Living Environments
FEITO, Y., BASSETT, D. R., & THOMPSON, D. L. (2012) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3182351913 · Cited by 159 · see citing works
Gait in Stroke: Assessment and Rehabilitation
Richards, C. L., Malouin, F., & Dean, C. M. (1999) · Clinics in Geriatric Medicine · doi:10.1016/s0749-0690(18)30034-x · Cited by 158 · see citing works
Gait Speed and Step-Count Monitor Accuracy in Community-Dwelling Older Adults
Storti, K. L., Gabriel, K. P., Brach, J. S., Talkowski, J. B., Richardson, C. R., & Kriska, A. M. (2008) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e318158b504 · Cited by 156 · see citing works
Newstead, A. H., Hinman, M. R., & Tomberlin, J. (2005) · Neurology Report · doi:10.1097/01.npt.0000282258.74325.cf · Cited by 153 · see citing works
Fulk, G. D., Ludwig, M., Dunning, K. K., Golden, S., Boyne, P., & West, T. (2011) · Neurology Report · doi:10.1097/npt.0b013e318218e2f2 · Cited by 142 · see citing works
Self-citationvan Loo, M. A., Moseley, A. M., Bosman, J. M., et al. (2004) · Brain Injury · doi:10.1080/02699050410001672314 · Cited by 135 · see citing works
Shaughnessy, M., Michael, K. M., Sorkin, J. D., & Macko, R. F. (2005) · Stroke · doi:10.1161/01.str.0000166202.00669.d2 · Cited by 133 · see citing works
Saremi, K., Marehbian, J., Yan, X., Régnaux, J.-P., Elashoff, R. E., Bussel, B., & Dobkin, B. H. (2006) · Neurorehabilitation and neural repair · doi:10.1177/1545968306287171 · Cited by 133 · see citing works
Limits of agreement (Bland-Altman method)
Sedgwick, P. M. (2013) · BMJ · doi:10.1136/bmj.f1630 · Cited by 112 · see citing works
Factors Associated with Health-Related Quality of Life in Chronic Spinal Cord Injury
Jain, N. B., Sullivan, M., Kazis, L. E., et al. (2007) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/phm.0b013e31804a7d00 · Cited by 98 · see citing works
Using Sensors to Measure Activity in People with Stroke
Fulk, G. D., & Sazonov, E. E. (2011) · Topics in Stroke Rehabilitation · doi:10.1310/tsr1806-746 · Cited by 83 · see citing works
Self-citationEcological Validity of Walking Speed Assessment After Traumatic Brain Injury
Moseley, A. M., Lanzarone, S., Bosman, J. M., et al. (2004) · Journal of Head Trauma Rehabilitation · doi:10.1097/00001199-200407000-00008 · Cited by 78 · see citing works
Gorter, J. W., Noorduyn, S. G., Obeid, J., & Timmons, B. W. (2012) · International Journal of Pediatrics · doi:10.1155/2012/329284 · Cited by 77 · see citing works
The Use of Pedometers in Stroke Survivors: Are They Feasible and How Well Do They Detect Steps?
Carroll, S. L., Greig, C. A., Lewis, S. J., McMurdo, M. E. T., Sniehotta, F. F., Johnston, M., Johnston, D. W., Scopes, J., & Mead, G. E. (2012) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2011.08.047 · Cited by 58 · see citing works
Motl, R. W., Snook, E. M., & Agiovlasitis, S. (2010) · Disability and health journal · doi:10.1016/j.dhjo.2010.02.003 · Cited by 51 · see citing works
Patient inclusion in goal setting during early inpatient rehabilitation after acquired brain injury
Dalton, C. M., Farrell, R. A., Souza, A. D., et al. (2011) · Clinical Rehabilitation · doi:10.1177/0269215511405230 · Cited by 51 · see citing works
Daily ambulatory activity levels in idiopathic Parkinson disease.
Skidmore, F. M., Mackman, C. A., Pav, B., Shulman, L. M., Garvan, C. W., Macko, R. F., & Heilman, K. M. (2008) · PubMed · Cited by 47 · see citing works
Pedometer step counts in individuals with neurological conditions
Elsworth, C., Dawes, H., Winward, C. E., Howells, K., Collett, J., Dennis, A., Sackley, C. M., & Wade, D. T. (2009) · Clinical Rehabilitation · doi:10.1177/0269215508098895 · Cited by 45 · see citing works
Plasticity and Reorganization of the Uninjured Brain
Bayona, N. A., Bitensky, J., & Teasell, R. W. (2005) · Topics in Stroke Rehabilitation · doi:10.1310/a422-g91u-q4hb-86xc · Cited by 42 · see citing works
Berg Balance Scale and Outcome Measures in Acquired Brain Injury
Feld, J., Rabadi, M. H., Blau, A. D., et al. (2001) · Neurorehabilitation and neural repair · doi:10.1177/154596830101500312 · Cited by 40 · see citing works
Gait Velocity and Community Ambulation: the Limits of Assessment
Lord, S. E., & Rochester, L. (2008) · Stroke · doi:10.1161/strokeaha.107.502203 · Cited by 18 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
Systematic review of the validity and reliability of consumer-wearable activity trackers
Evenson, K. R., Goto, M. M., & Furberg, R. D. (2015) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-015-0314-1 · Cited by 1,232 · see citing works
Fuller, D., Colwell, E., Low, J., Orychock, K., Tobin, M. A., Simango, B., Buote, R., Van Heerden, D., Luan, H., Cullen, K., et al. (2020) · JMIR mHealth and uHealth · doi:10.2196/18694 · Cited by 715 · see citing works
Accuracy of Fitbit Devices: Systematic Review and Narrative Syntheses of Quantitative Data
Feehan, L. M., Geldman, J., Sayre, E. C., Park, C., Ezzat, A. M., Yoo, J. Y., Hamilton, C. B., & Li, L. C. (2018) · JMIR mHealth and uHealth · doi:10.2196/10527 · Cited by 616 · see citing works
Ferguson, T., Rowlands, A. V., Olds, T., & Maher, C. (2015) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-015-0201-9 · Cited by 468 · see citing works
Shin, G., Jarrahi, M. H., Fei, Y., Karami, A., Gafinowitz, N., Byun, A., & Lu, X. (2019) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2019.103153 · Cited by 326 · see citing works
Behavior Change Techniques Present in Wearable Activity Trackers: A Critical Analysis
Mercer, K., Li, M., Giangregorio, L., Burns, C., & Grindrod, K. (2016) · JMIR mHealth and uHealth · doi:10.2196/mhealth.4461 · Cited by 304 · see citing works
Remote Physical Activity Monitoring in Neurological Disease: A Systematic Review.
Block, V. A. J., Pitsch, E., Tahir, P., Cree, B. A. C., Allen, D. D., & Gelfand, J. M. (2016) · PLOS ONE · doi:10.1371/journal.pone.0154335 · Cited by 198 · see citing works
“This study is listed under both diagnostic headings and results are analyzed by diagnosis group.[126] Monitoring duration was usually between 2 and 6 days (28 studies, 68.”
BackgroundInfluentialJohansson, D., Malmgren, K., & Alt Murphy, M. (2018) · Journal of Neurology · doi:10.1007/s00415-018-8786-y · Cited by 188 · see citing works
Straiton, N., Alharbi, M., Bauman, A., Neubeck, L., Gullick, J., Bhindi, R., & Gallagher, R. (2018) · Maturitas · doi:10.1016/j.maturitas.2018.03.016 · Cited by 147 · see citing works
Step count accuracy and reliability of two activity tracking devices in people after stroke
Schaffer, S. D., Holzapfel, S. D., Fulk, G., & Bosch, P. R. (2017) · Physiotherapy Theory and Practice · doi:10.1080/09593985.2017.1354412 · Cited by 54 · see citing works
Self-citationRozanski, G. M., Aqui, A., Sivakumaran, S., & Mansfield, A. (2018) · JMIR Cardio · doi:10.2196/cardio.8199 · Cited by 36 · see citing works
Støve, M. P., & Larsen, B. T. (2020) · European Journal of Physiotherapy · doi:10.1080/21679169.2019.1628300 · Cited by 5 · see citing works
- Authors
- Fulk, G. D., Combs, S. A., Danks, K. A., Nirider, C. D., Raja, B., & Reisman, D. S.
- Affiliations
- Clarkson University (US)
- University of Indianapolis (US)
- University of Delaware (US)
- C.D. Nirider, PT, DPT, Touchstone Neurorecovery Center, Conroe, Texas.
- Western University of Health Sciences (US)
- Corresponding author
- Fulk, George D.
- Venue
- Physical Therapy
- Publisher
- Oxford University Press (OUP)
- Published
- 2014-02-01
- Volume
- 94
- Issue
- 2
- Pages
- 222-229
- ISSN
- 0031-9023 (ISSN-L)
- 1538-6724
- OpenAlex
- W2110108424
- Cited by
- 182
- References
- 51
- Citations by year
- 2026: 5 · 2025: 7 · 2024: 7 · 2023: 4 · 2022: 11 · 2021: 17 · 2020: 23 · 2019: 20 · 2018: 23 · 2017: 26 · 2016: 20 · 2015: 14 · 2014: 5
- FWCI
- 9.03
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Physical Therapy (publishedVersion)
- PubMed (publishedVersion)
- Scholarly Commons (University of the Pacific) (submittedVersion)
- Topics
- Health Sciences › Medicine › Physiology › Physical Activity and Health
- Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
- Health Sciences › Medicine › Rehabilitation › Stroke Rehabilitation and Recovery
- Keywords
- wearable activity trackers, step count accuracy, stroke, traumatic brain injury, pedometers, consumer wearable devices, 2-minute walk test, walking speed
- MeSH terms
- Brain Injuries, Cross-Sectional Studies, Female, Humans, Male, Middle Aged, United States, Videotape Recording, Monitoring, Ambulatory, Gait Disorders, Neurologic, Stroke
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review