Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 394

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Safety and efficacy of intravenous iron therapy in reducing requirement for allogeneic blood transfusion: systematic review and meta-analysis of randomised clinical trials

Open access
Litton, E., Xiao, J., Ho, K. M.·2013·BMJ

Abstract

OBJECTIVES: To evaluate the efficacy and safety of intravenous iron, focusing primarily on its effects on haemoglobin, requirement for transfusion, and risk of infection. DESIGN: Systematic review and meta-analysis of randomised controlled trials investigating the safety and efficacy of intravenous iron therapy. DATA SOURCES: Randomised controlled trials from Medline, Embase, and the Cochrane Central Register of Controlled Trials from 1966 to June 2013, with no language restrictions. ELIGIBILITY CRITERIA FOR SELECTING STUDIES: Eligible trials were randomised controlled trials of intravenous iron compared with either no iron or oral iron. Crossover and observational studies were excluded. MAIN OUTCOME MEASURES: Change in haemoglobin concentration and risk of allogeneic red blood cell transfusion (efficacy) and risk of infection (safety). RESULTS: Of the 75 trials meeting the inclusion criteria, 72 studies including 10 605 patients provided quantitative outcome data for meta-analysis. Intravenous iron was associated with an increase in haemoglobin concentration (standardised mean difference 6.5 g/L, 95% confidence interval 5.1 g/L to 7.9 g/L) and a reduced risk of requirement for red blood cell transfusion (risk ratio 0.74, 95% confidence interval 0.62 to 0.88), especially when intravenous iron was used with erythroid stimulating agents (ESAs) or in patients with a lower baseline plasma ferritin concentration. There were no significant interactions between the efficacy of intravenous iron and type or dose administered. Intravenous iron was, however, associated with a significant increase in risk of infection (relative risk 1.33, 95% confidence interval 1.10 to 1.64) compared with oral or no iron supplementation. The results remained similar when only high quality trials were analysed. CONCLUSIONS: Intravenous iron therapy is effective in increasing haemoglobin concentration and reducing the risk of allogeneic red blood cell transfusion and could have broad applicability to a range of acute care settings. This potential benefit is counterbalanced by a potential increased risk of infection.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/bmj.f4822

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 394

Metadata

Authors
Litton, E., Xiao, J., & Ho, K. M.
Venue
BMJ
Publisher
BMJ
Published
2013-08-15
Volume
347
Issue
aug15 1
Pages
f4822-f4822
ISSN
1756-1833 (ISSN-L)
OpenAlex
W2126707535
Cited by
394
References
3
FWCI
5.09
Type
journal article
Language
en
Open access
hybrid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Safety and efficacy of intravenous iron therapy in reducing requirement for allogeneic blood transfusion: systematic review and meta-analysis of randomised clinical trials. https://app.cochat.ai/papers/10.1136/bmj.f4822
The paper
Litton, E., Xiao, J., & Ho, K. M. (2013). Safety and efficacy of intravenous iron therapy in reducing requirement for allogeneic blood transfusion: systematic review and meta-analysis of randomised clinical trials. BMJ. https://doi.org/10.1136/bmj.f4822

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.