Cost analysis of the flash monitoring system (FreeStyle Libre 2) in adults with type 1 diabetes mellitus
Open accessAbstract
INTRODUCTION: Compare cost of the interstitial liquid glucose flash monitoring (FM) system (FreeStyle Libre 2) versus self-monitoring of blood glucose (SMBG) in adults with type 1 diabetes mellitus (T1DM) in Spain. RESEARCH DESIGN AND METHODS: A model was developed to estimate, with the perspective of the Spanish health system, the annual costs associated with glucose monitoring and hypoglycemic events management in T1DM population, with multiple insulin daily doses (MDI). According to published evidence, rate of severe hypoglycemia (SHE) of 4.90 episodes per patient-year was applied. Reduction of SHE (58.6%) was modeled associated with FM use. Published rates of hospital care (20.2%) and subsequent admission (16%) were assumed for SHE. The daily consumption of strips and lancets was 9 in patients with SMBG (before and after 4 daily intakes and at bedtime) and 0.5 for FM users (according to IMPACT trial findings). Annual consumption of 26 FM sensors was considered (1 every 14 days). Unit costs (in € of 2019, excluding VAT) were obtained from literature and national databases. Sensitivity analyses (SA) were carried out to evaluate the model robustness. RESULTS: The total annual cost/patient was €4437 for SMBG and €2526 for FM. The use of FM would be associated with an annual savings in the costs of monitoring and managing hypoglycemic events of €1911 per patient-year. In a hypothetical cohort of 1000 patients with T1DM MDI, FM could avoid in 1 year 4900 SHE, 93 hospitalizations for SHE. In addition, the use of FM would generate total savings of up to €1 910 000 per year. In the SA with alternative hypoglycemia events rates and use of strips and lancets, and including non-SHE episodes, savings from €370 000 to €1 760 000 were observed with FM. CONCLUSIONS: The use of the FM system to monitor glucose in adults with T1DM treated with MDI, would reduce hypoglycemic events and would result in cost savings for the health system.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Insulin pump therapy and CGM reduce HbA1c, hypoglycaemia, diabetes burden and distress, and are associated with higher quality of life compared to usual care.
“Insulin pump therapy and continuous glucose monitor (CGM) reduce Haemoglobin A1c (HbA1c), hypoglycaemia, diabetes burden and distress, and are associated with higher quality of life (QOL) compared to usual care.”
From Social disadvantage and technology use among adults with type 1 diabetes in Quebec: A cross‐sectional study using data from the Canadian <scp>T1D</scp> ( <scp>BETTER</scp> ) Registry (2025) · cites this paper as [3]
The Introduction and Research design and methods (pages unavailable) report fewer hypoglycaemic episodes with flash monitoring than with finger-prick self-monitoring in adults with type 1 diabetes. The paper analyses people receiving multiple daily insulin doses, not insulin pump therapy, and does not establish reductions in HbA1c, diabetes burden or distress, or improved quality of life for the therapies named in the claim. (LLM, conf=0.88)
Experimental — accuracy not yet measuredEconomic analyses generally support the cost-effectiveness of diabetes technologies owing to a reduction in hypoglycaemia and acute and chronic diabetes complications.
“While these technologies are expensive, economic analyses generally support their cost‐effectiveness owing to a reduction in hypoglycaemia and acute and chronic diabetes complications.”
From Social disadvantage and technology use among adults with type 1 diabetes in Quebec: A cross‐sectional study using data from the Canadian <scp>T1D</scp> ( <scp>BETTER</scp> ) Registry (2025) · cites this paper as [3]
The Conclusions (page unavailable) report that flash monitoring was associated with lower modeled costs for adults with type 1 diabetes, chiefly through fewer hypoglycemic episodes; they also note cost savings reported in other settings. The paper does not establish that diabetes technologies generally are cost-effective or that reductions in acute and chronic complications drive those savings. (LLM, conf=0.87)
Experimental — accuracy not yet measuredPrevious studies demonstrate glycaemic benefits for CGM and insulin pump.
“HbA1c was lower among CGM and insulin pump users in the BETTER Registry, which is consistent with previous studies demonstrating glycaemic benefits for these technologies.”
From Social disadvantage and technology use among adults with type 1 diabetes in Quebec: A cross‐sectional study using data from the Canadian <scp>T1D</scp> ( <scp>BETTER</scp> ) Registry (2025) · cites this paper as [3]
The Introduction reports that a trial found fewer hypoglycaemic episodes with flash glucose monitoring, supporting a glycaemic benefit for that technology. The paper does not report a glycaemic benefit for insulin pumps, and the Research design and methods table gives baseline HbA1c rather than an HbA1c reduction. Neither passage has a page number in our copy. (LLM, conf=0.87)
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Severe hypoglycemia and risks of vascular events and death
Zoungas, S., Patel, A., Chalmers, J., de Galan, B. E., Li, Q., Billot, L., Woodward, M., Ninomiya, T., Neal, B., MacMahon, S., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1003795 · Cited by 1,471 · see citing works
Seaquist, E. R., Anderson, J., Childs, B., Cryer, P., Dagogo-Jack, S., Fish, L., Heller, S. R., Rodriguez, H., Rosenzweig, J., & Vigersky, R. (2013) · Diabetes Care · doi:10.2337/dc12-2480 · Cited by 1,389 · see citing works
Bolinder, J., Antuna, R., Geelhoed-Duijvestijn, P., Kröger, J., & Weitgasser, R. (2016) · The Lancet · doi:10.1016/s0140-6736(16)31535-5 · Cited by 893 · see citing works
Miller, K. M., Beck, R. W., Bergenstal, R. M., Goland, R. S., Haller, M. J., McGill, J. B., Rodriguez, H., Simmons, J. H., Hirsch, I. B., & for the T1D Exchange Clinic Network (2013) · Diabetes Care · doi:10.2337/dc12-1770 · Cited by 505 · see citing works
Khunti, K., Alsifri, S., Aronson, R., Cigrovski Berković, M., Enters‐Weijnen, C., Forsén, T., Galstyan, G., Geelhoed‐Duijvestijn, P., Goldfracht, M., Gydesen, H., et al. (2016) · Diabetes Obesity and Metabolism · doi:10.1111/dom.12689 · Cited by 276 · see citing works
Longitudinal study of new and prevalent use of self-monitoring of blood glucose
Karter, A. J., Parker, M. M., Moffet, H. H., Spence, M. M., Chan, J., Ettner, S. L., & Selby, J. V. (2006) · Diabetes Care · doi:10.2337/dc06-2073 · Cited by 139 · see citing works
Beck, R. W., Bergenstal, R. M., Riddlesworth, T. D., & Kollman, C. (2019) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2018.0362 · Cited by 42 · see citing works
Flagged first, then by citations
Research works printed but not linked: 33
- [1]Lovic D, Piperidou A, Zografou I, et al The growing epidemic of diabetes mellitus. Curr Vasc Pharmacol 2019. 30961501
- [2]Lopez-Bastida J, Boronat M, Moreno JO, et al Costs, outcomes and challenges for diabetes care in Spain. Global Health 2013; 9: 17. 10.1186/1744-8603-9-17 23635075 PMC3658938 · DOI
- [3]Escobar-Jiménez F Guías clínicas en diabetes mellitus tipo 1. Endocrinología y Nutrición 2009; 56: 15– 17. 10.1016/S1575-0922(09)73510-7 20542220 · DOI
- [5]Brod M, Christensen T, Thomsen TL, et al The impact of non-severe hypoglycemic events on work productivity and diabetes management. Value Health 2011; 14: 665– 71. 10.1016/j.jval.2011.02.001 21839404 · DOI · Paper page
- [6]Baena G, Carral F, del Mar Roca M, et al ¿Es posible alcanzar en La práctica clínica Los objetivos de control metabólico establecidos para pacientes Con diabetes mellitus tipo 1. Endocrinología y Nutrición 2008; 55: 442– 7. 10.1016/S1575-0922(08)75840-6 22980459 · DOI
- [7]Idris I, Peng X, He X, et al The trend of high-dose insulin usage among patients with diabetes in the UK: a retrospective study. Diabetes Ther 2018; 9: 2245– 57. 10.1007/s13300-018-0515-0 30269224 PMC6250629 · DOI
- [8]Hansen MV, Pedersen-Bjergaard U, Heller SR, et al Frequency and motives of blood glucose self-monitoring in type 1 diabetes. Diabetes Res Clin Pract 2009; 85: 183– 8. 10.1016/j.diabres.2009.04.022 19497633 · DOI
- [10]Menéndez Torre E, Tartón García T, Ortega Millán C, et al Recomendaciones 2012 de la Sociedad Española de diabetes sobre La utilización de tiras reactivas para La medición de la glucemia capilar en personas Con diabetes. Avances en Diabetología 2012; 28: 3– 9. 10.1016/j.avdiab.2012.01.002 · DOI
- [12]Vincze G, Barner JC, Lopez D Factors associated with adherence to self-monitoring of blood glucose among persons with diabetes. Diabetes Educ 2004; 30: 112– 25. 10.1177/014572170403000119 14999899 · DOI
- [13]Vidal Flor M, Jansà Morató M, Galindo Rubio M, et al Factors associated to adherence to blood glucose self-monitoring in patients with diabetes treated with insulin. The dapa study. Endocrinol Diabetes Nutr 2018; 65: 99– 106. 10.1016/j.endinu.2017.10.005 29249677 · DOI
- [16]Oskarsson P, Antuna R, Geelhoed-Duijvestijn P, et al Impact of flash glucose monitoring on hypoglycaemia in adults with type 1 diabetes managed with multiple daily injection therapy: a pre-specified subgroup analysis of the impact randomised controlled trial. Diabetologia 2018; 61: 539– 50. 10.1007/s00125-017-4527-5 29273897 PMC6448969 · DOI
- [17]Haak T, Hanaire H, Ajjan R, et al Flash glucose-sensing technology as a replacement for blood glucose monitoring for the management of insulin-treated type 2 diabetes: a multicenter, open-label randomized controlled trial. Diabetes Ther 2017; 8: 55– 73. 10.1007/s13300-016-0223-6 28000140 PMC5306122 · DOI · Paper page
- [19]Mezquita-Raya P, Reyes-García R, Moreno-Pérez O, et al Grupo de trabajo de diabetes mellitus de la Sociedad Española de Endocrinología Y Nutrición (seen). Documento de posicionamiento: evaluación Y manejo de la hipoglucemia en El paciente Con diabetes mellitus. Grupo de Trabajo de diabetes mellitus de la Sociedad Española de Endocrinología Y Nutrición. Endocrinol Nutr 2013; 60: 517.e1– 517.e18.23916172
- [21]International Hypoglycaemia Study Group Glucose concentrations of less than 3.0 mmol/l (54 mg/dl) should be reported in clinical trials: a joint position statement of the American Diabetes Association and the European Association for the Study of Diabetes. Diabetologia 2017; 60: 3– 6. 10.1007/s00125-016-4146-6 27872948 PMC6518070 · DOI
- [22]Lammert M, Hammer M, Frier BM Management of severe hypoglycaemia: cultural similarities, differences and resource consumption in three European countries. J Med Econ 2009; 12: 269– 80. 10.3111/13696990903310501 20001569 · DOI
- [23]Crespo C, Brosa M, Soria-Juan A, et al Costes directos de la diabetes mellitus Y de Sus complicaciones en España (estudio SECCAID: Spain estimated cost Ciberdem-Cabimer in diabetes). Avances en Diabetología 2013; 29: 182– 9. 10.1016/j.avdiab.2013.07.007 · DOI
- [24]Barranco RJ, Gomez-Peralta F, Abreu C, et al Incidence and care-related costs of severe hypoglycaemia requiring emergency treatment in Andalusia (Spain): the PAUEPAD project. Diabet Med 2015; 32: 1520– 6. 10.1111/dme.12843 26118472 PMC4755037 · DOI
- [25]Hammer M, Lammert M, Mejías SM, et al Costs of managing severe hypoglycaemia in three European countries. J Med Econ 2009; 12: 281– 90. 10.3111/13696990903336597 20001570 · DOI
- [26]Khunti K, Cigrovski Berković M, Ludvik B, et al Regional variations in definitions and rates of hypoglycaemia: findings from the global HAT observational study of 27 585 people with type 1 and insulin-treated type 2 diabetes mellitus. Diabet Med 2018. 10.1111/dme.13662. [Epub ahead of print: 05 May 2018]. 29729048 PMC6099252 · DOI
- [27]UK Hypoglycaemia Study Group Risk of hypoglycaemia in types 1 and 2 diabetes: effects of treatment modalities and their duration. Diabetologia 2007; 50: 1140– 7. 10.1007/s00125-007-0599-y 17415551 · DOI · Paper page
- [28]Edridge CL, Dunkley AJ, Bodicoat DH, et al Prevalence and incidence of hypoglycaemia in 532,542 people with type 2 diabetes on oral therapies and insulin: a systematic review and meta-analysis of population based studies. PLoS One 2015; 10: e0126427. 10.1371/journal.pone.0126427 26061690 PMC4465495 · DOI
- [29]Orozco-Beltrán D, Mezquita-Raya P, Ramírez de Arellano A, et al Self-Reported frequency and impact of hypoglycemic events in Spain. Diabetes Ther 2014; 5: 155– 68. 10.1007/s13300-014-0057-z 24515748 PMC4065286 · DOI
- [30]Parekh W, Hoskins N, Baker-Knight J, et al The economic burden of insulin-related hypoglycemia in Spain. Diabetes Ther 2017; 8: 899– 913. 10.1007/s13300-017-0285-0 28653237 PMC5544621 · DOI
- [31]Hellmund R, Weitgasser R, Blissett D Cost calculation for a flash glucose monitoring system for UK adults with type 1 diabetes mellitus receiving intensive insulin treatment. Diabetes Res Clin Pract 2018; 138: 193– 200. 10.1016/j.diabres.2018.01.028 29410149 · DOI
- [32]Hellmund R, Weitgasser R, Blissett D Cost Calculation for a Flash Glucose Monitoring System for Adults with Type 2 Diabetes Mellitus Using Intensive Insulin - a UK Perspective. Eur Endocrinol 2018; 14: 86– 92. 10.17925/EE.2018.14.2.86 30349600 PMC6182928 · DOI
- [35]Wagner J, Malchoff C, Abbott G Invasiveness as a barrier to self-monitoring of blood glucose in diabetes. Diabetes Technol Ther 2005; 7: 612– 9. 10.1089/dia.2005.7.612 16120035 · DOI
- [36]Zambanini A, Feher MD Needle phobia in type 1 diabetes mellitus. Diabet Med 1997; 14: 321– 3. 10.1002/(SICI)1096-9136(199704)14:4<321::AID-DIA356>3.0.CO;2-H 9113487 · DOI
- [37]Rittmeyer D, Schmid C, Haug C, et al A novel glucose monitoring system versus a conventional SMBG system: time and step analysis. Paris, France: Poster ATTD-0466. 8th International Conference on Advanced Technologies & Treatments for Diabetes, 18–21 February 2015.
- [38]Bilir SP, Hellmund R, Wehler B, et al Cost-Effectiveness analysis of a flash glucose monitoring system for patients with type 1 diabetes receiving intensive insulin treatment in Sweden. Eur Endocrinol 2018; 14: 73– 9. 10.17925/EE.2018.14.2.73 30349598 PMC6182929 · DOI
- [39]Gil-Ibáñez MT, Aispuru GR Análisis de coste-efectividad de control glucémico con FreeStyle Libre® en pacientes diabéticos tipo 1 en atención primaria de salud de Burgos. [Cost-effectiveness analysis of glycaemic control of a glucose monitoring system (FreeStyle Libre®) for patients with type 1 diabetes in primary health care of Burgos]. Enferm Clin 2019; 8621: 30295– 5. 31492523
- [40]Vellopoulou K, Kourlaba G, Doupis J, et al Economic Evaluation of Flash Glucose Monitoring Compared To Self - Monitoring of Blood Glucose For The Management of Patients Receiving Intensive Insulin With Diabetes Type 1 And Type 2 In Greece. Value in Health 2017; 20: A585– 585. 10.1016/j.jval.2017.08.1056 · DOI
- [42]Li H, Bilir SP, Wehler EA, et al Cost effectiveness analysis of a flash glucose monitoring system for type 2 diabetes (T2DM) patients receiving intensive insulin treatment in Europe. Value in Health 2016; 19: A698– 698. 10.1016/j.jval.2016.09.2016 · DOI
- [43]Li H, Bilir SP, Donga P, et al Cost effectiveness analysis of flash glucose monitoring for type 2 diabetes patients receiving insulin treatment in the UK. Value in Health 2014; 17: A351– 351. 10.1016/j.jval.2014.08.730 27200680 · DOI
Cited by
Sorted by citations
Grunberger, G., Sherr, J., Allende, M., Blevins, T., Bode, B., Handelsman, Y., Hellman, R., Lajara, R., Roberts, V. L., Rodbard, D., et al. (2021) · Endocrine Practice · doi:10.1016/j.eprac.2021.04.008 · Cited by 288 · see citing works
Khodabandehloo, P., Fakembe, P., Senga, J., Shulman, R., Lipscombe, L. L., Witteman, H. O., Banerjee, A., Presseau, J., Nakhla, M., Dogba, M. J., et al. (2025) · Diabetes, Obesity and Metabolism · doi:10.1111/dom.16426 · Cited by 6 · see citing works
“1,3,5 After CGM use increased in Australia following the introduction of public funding, HbA1c and rates of DKA were reduced.”
- Authors
- Oyagüez, I., Merino-Torres, J. F., Brito, M., Bellido, V., Cardona-Hernandez, R., Gomez-Peralta, F., & Morales-Perez, F.
- Affiliations
- Iberia (Spain) (ES)
- Universitat de València (ES)
- Hospital Universitario Puerta de Hierro Majadahonda (ES)
- Hospital de Cruces (ES)
- Division of Pediatric Endocrinology, Hospital Sant Joan de Deu, Barcelona, Catalunya, Spain
- Endocrinology and Nutrition Unit, Segovia General Hospital, Segovia, Spain
- Department of Endocrinology and Nutrition, University Hospital Complex Badajoz, Badajoz, Extremadura, Spain
- Corresponding author
- Oyagüez, Itziar
- Venue
- BMJ Open Diabetes Research & Care
- Publisher
- BMJ
- Published
- 2020-07
- Volume
- 8
- Issue
- 1
- Pages
- e001330
- ISSN
- 2052-4897 (ISSN-L)
- PMC
- PMC7375427
- OpenAlex
- W3045463944
- Cited by
- 33
- References
- 7
- Citations by year
- 2026: 2 · 2025: 4 · 2024: 7 · 2023: 6 · 2022: 7 · 2021: 6 · 2020: 1
- FWCI
- 3.77
- Type
- journal article
- Language
- en
- Open access
- gold
- doi.org
- Licence
- Locations
- BMJ Open Diabetes Research & Care (publishedVersion, cc-by-nc)
- PubMed Central (publishedVersion, cc-by-nc)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Funders
- Abbott Diabetes Care (Abbott-Dc-2019-03)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Social Sciences › Economics, Econometrics and Finance › Economics and Econometrics › Health Systems, Economic Evaluations, Quality of Life
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Keywords
- flash glucose monitoring, FreeStyle Libre 2, type 1 diabetes, cost analysis, self-monitoring of blood glucose, severe hypoglycemia, hypoglycemia management, hospital costs, cost reduction, health system costs, adults
- MeSH terms
- Adult, Blood Glucose, Diabetes Mellitus, Type 1, Humans, Hypoglycemic Agents, Spain, Blood Glucose Self-Monitoring
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review