The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Longitudinal Study of New and Prevalent Use of Self-Monitoring of Blood Glucose
Open accessAbstract
OBJECTIVE: We sought to assess longitudinal association between self-monitoring of blood glucose (SMBG) and glycemic control in diabetic patients from an integrated health plan (Kaiser Permanente Northern California). RESEARCH DESIGN AND METHODS: Longitudinal analyses of glycemic control among 1) 16,091 patients initiating SMBG (new-user cohort) and 2) 15,347 ongoing users of SMBG (prevalent-user cohort). SMBG frequency was based on pharmacy use (number of blood glucose test strips dispensed), and glycemic control was based on HbA(1c) (A1C). In the new-user cohort, ANCOVA models (pre- and posttest design) were used to assess the effect of initiating SMBG. In the prevalent-user cohort, repeated-measure, mixed-effects models with random-intercept and time-dependent covariates were used to assess changes in SMBG and A1C. All models were stratified by therapy (no medications, oral agents only, or insulin) and adjusted for baseline A1C, sociodemographics, insulin injection frequency, comorbidity index, medication adherence, smoking status, health care use, and provider specialty. RESULTS: Greater SMBG practice frequency among new users was associated with a graded decrease in A1C (relative to nonusers) regardless of diabetes therapy (P < 0.0001). Changes in SMBG frequency among prevalent users were associated with an inverse graded change in A1C only among pharmacologically treated patients (P < 0.0001). CONCLUSIONS: These observational findings are consistent with short-term benefits of initiating SMBG practice for all patients but continuing benefits only for pharmacologically treated patients. Differences in effectiveness between new versus prevalent users of SMBG have implications for guideline development and interpretation of observational outcomes data.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source doesn’t support the claim as written.
In the citing paper
“For individuals with type 2 diabetes, cross-sectional and longitudinal observational studies in several countries have failed to demonstrate an improvement in glycemic control (as measured by mean HbA 1c concentration) associated with the use of SMBG (102-104).”
From Guidelines and recommendations for laboratory analysis in the diagnosis and management of diabetes mellitus (2011) · cites this paper as [103]
Checked by a reasoning model — may be wrong.
Experimental — accuracy not yet measuredThe cited source doesn’t support the claim as written.
In the citing paper
“Frequency of meter use did not predict HbA 1c .”
From Guidelines and recommendations for laboratory analysis in the diagnosis and management of diabetes mellitus (2011) · cites this paper as [103]
Checked by a reasoning model — may be wrong.
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1993) · New England Journal of Medicine · doi:10.1056/nejm199309303291401 · Cited by 24,667
Introductory Econometrics: A Modern Approach
Wooldridge, J. M. (1999) · Cited by 14,451
Stratton, I. M. (2000) · BMJ · doi:10.1136/bmj.321.7258.405 · Cited by 9,059
Standards of medical care in diabetes—2014
American Diabetes Association (2014) · Diabetes Care · doi:10.2337/dc14-s014 · Cited by 4,572
Standards of Medical Care in Diabetes–2006
American Diabetes Association (2006) · Diabetes Care · doi:10.2337/diacare.29.s1.06.s4 · Cited by 1,885
Krieger, N. (1992) · American Journal of Public Health · doi:10.2105/ajph.82.5.703 · Cited by 1,654
Evaluating medication effects outside of clinical trials: new-user designs
Ray, W. A. (2003) · American Journal of Epidemiology · doi:10.1093/aje/kwg231 · Cited by 1,646
The assessment of refill compliance using pharmacy records: Methods, validity, and applications
Steiner, J. F., & Prochazka, A. V. (1997) · Journal of Clinical Epidemiology · doi:10.1016/s0895-4356(96)00268-5 · Cited by 1,193
Assessing the sensitivity of regression results to unmeasured confounders in observational studies
Lin, D. Y., Psaty, B. M., & Kronmal, R. A. (1998) · Biometrics · doi:10.2307/2533848 · Cited by 742
Karter, A. J., Ackerson, L. M., Darbinian, J. A., D’Agostino, R. B., Ferrara, A., Liu, J., & Selby, J. V. (2001) · The American Journal of Medicine · doi:10.1016/s0002-9343(01)00742-2 · Cited by 595
Self-citation
Cited by
Sacks, D. B., Arnold, M., Bakris, G. L., Bruns, D. E., Horvath, A. R., Kirkman, M. S., Lernmark, A., Metzger, B. E., & Nathan, D. M. (2011) · Clinical Chemistry · doi:10.1373/clinchem.2010.161596 · Cited by 1,360
Hypoglycemic episodes and risk of dementia in older patients with type 2 diabetes mellitus
Whitmer, R. A. (2009) · JAMA · doi:10.1001/jama.2009.460 · Cited by 1,128
Sacks, D. B., Arnold, M., Bakris, G. L., Bruns, D. E., Horvath, A. R., Kirkman, M. S., Lernmark, A., Metzger, B. E., & Nathan, D. M. (2011) · Diabetes Care · doi:10.2337/dc11-9998 · Cited by 718
Farmer, A., Wade, A., Goyder, E., Yudkin, P., French, D., Craven, A., Holman, R., Kinmonth, A.-L., & Neil, A. (2007) · BMJ · doi:10.1136/bmj.39247.447431.be · Cited by 407
1,5-anhydroglucitol (GlycoMark™) as a marker of short-term glycemic control and glycemic excursions
Dungan, K. M. (2008) · Expert Review of Molecular Diagnostics · doi:10.1586/14737159.8.1.9 · Cited by 207
Metadata
- Authors
- Karter, A. J., Parker, M. M., Moffet, H. H., Spence, M. M., Chan, J., Ettner, S. L., & Selby, J. V.
- Affiliations
- Kaiser Permanente (US)
- University of California, Los Angeles (US)
- Venue
- Diabetes Care
- Publisher
- American Diabetes Association
- Published
- 2006-08-01
- Volume
- 29
- Issue
- 8
- Pages
- 1757-1763
- ISSN
- 0149-5992 (ISSN-L)
- 1935-5548
- PMC
- PMC2213628
- OpenAlex
- W2009637382
- Cited by
- 139
- References
- 27
- Citations by year
- 2025: 4 · 2024: 1 · 2023: 2 · 2022: 5 · 2021: 2 · 2020: 6 · 2019: 2 · 2018: 2 · 2017: 7 · 2016: 5 · 2015: 7 · 2014: 4 · 2013: 6 · 2012: 11
- FWCI
- 11.32
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Diabetes Care (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- Funders
- National Institutes of Health
- National Institute of Diabetes and Digestive and Kidney Diseases (R01 DK61678-02, R01DK061678)
- Topics
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Research
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Management and Education
- Health Sciences › Medicine › Endocrinology, Diabetes and Metabolism › Diabetes Treatment and Management
- Keywords
- self-monitoring of blood glucose, glycemic control, HbA1c, diabetes mellitus, blood glucose test strips, insulin therapy, oral antidiabetic drugs, medication adherence, Kaiser Permanente
- MeSH terms
- Aged, Blood Glucose, Female, Humans, Longitudinal Studies, Male, Middle Aged, Blood Glucose Self-Monitoring
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Longitudinal Study of New and Prevalent Use of Self-Monitoring of Blood Glucose. https://app.cochat.ai/papers/10.2337/dc06-2073
- The paper
- Karter, A. J., Parker, M. M., Moffet, H. H., Spence, M. M., Chan, J., Ettner, S. L., & Selby, J. V. (2006). Longitudinal Study of New and Prevalent Use of Self-Monitoring of Blood Glucose. Diabetes Care. https://doi.org/10.2337/dc06-2073
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.