The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Short‐ and Long‐Term Complications After Slowly Resorbable Biosynthetic P4HB Mesh (Phasix) Implantation in European Centres: A Protocol Paper for a Multiregistry Study
Abstract
Background: Phasix mesh is a fully resorbable synthetic mesh for use in clean and contaminated ventral incisional hernia repairs. Long-term absorbable Phasix mesh appears to be a safe and promising device in incisional hernia repair, with low recurrence rates; however, data on long-term complications after surgery, particularly after the resorption period of the mesh, are scarce. Methods and analysis: This protocol describes a study of several European registries on the use of a Phasix mesh in incisional hernia repair. The primary endpoint of the study is long-term complications at 2–5 year follow-up after mesh implantation, with secondary endpoints including hernia recurrence and complications during short-term follow-up. Ethics and dissemination: Ethical approval was not required for this protocol as the study is based on anonymised registry data collected with prior patient consent in each registry. Each participating registry has its own ethical approval process, and this study will adhere to those regulations. The results will be disseminated through peer-reviewed publications and conference presentations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The protocol for this study was published in detail elsewhere [12].”
From Long‐Term Outcomes After Slowly Resorbable P4HB Mesh Implantation: A Multicenter Analysis From European Registry (2026) · cites this paper as [12]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Roth, J. S., Anthone, G. J., Selzer, D. J., Poulose, B. K., Pierce, R. A., Bittner, J. G., Hope, W. W., Dunn, R. M., Martindale, R. G., Goldblatt, M. I., et al. (2021) · Annals of Medicine and Surgery · doi:10.1016/j.amsu.2020.12.002 · Cited by 40
Van den Dop, L. M., Van Rooijen, M. M. J., Tollens, T., Jørgensen, L. N., De Vries-Reilingh, T. S., Piessen, G., Köckerling, F., Miserez, M., Dean, M., Berrevoet, F., et al. (2023) · Annals of Surgery Open · doi:10.1097/as9.0000000000000366 · Cited by 21
Self-citation
Research works printed but not linked: 22
- 10.1016/j.jss.2013.03.044 · DOI · Paper page
- Deeken, 2013, Characterization of the mechanical strength, resorption properties, and histologic characteristics of a fully absorbable material (poly-4-hydroxybutyrate-phasix mesh) in a porcine model of hernia repair, ISRN Surg, 2013, 238067, 10.1155/2013/238067 · DOI · Paper page
- van Rooijen, 2020, Outcomes of a new slowly resorbable biosynthetic mesh (phasixTM) in potentially contaminated incisional hernias: a prospective, multi-center, single-arm trial, Int J Surg, 83, 31, 10.1016/j.ijsu.2020.08.053 · DOI
- Deeken CR , Chen DC , Lopez-Cano M , et al . Fully resorbable poly-4-hydroxybutyrate (P4HB) mesh for soft tissue repair and reconstruction: a scoping review. Front Surg 2023;10. doi:10.3389/fsurg.2023.1157661 · DOI · Paper page
- Schecter, 2022, Single-stage abdominal wall reconstruction in contaminated and dirty wounds is safe: a single center experience, Surg Endosc, 36, 5766, 10.1007/s00464-022-09058-4 · DOI
- Buell JF , Flaris AN , Raju S , et al . Long-term outcomes in complex abdominal wall reconstruction repaired with absorbable biologic polymer scaffold (Poly-4-Hydroxybutyrate). Ann Surg Open 2021;2. doi:10.1097/AS9.0000000000000032 · DOI · Paper page
- Roth, 2018, Prospective evaluation of poly-4-hydroxybutyrate mesh in CDC class I/high-risk ventral and incisional hernia repair: 18-month follow-up, Surg Endosc, 32, 1929, 10.1007/s00464-017-5886-1 · DOI · Paper page
- Layer, 2023, Incisional hernia repair with a slowly absorbable P4HB mesh: what happens after the mesh disappears? A retrospective longitudinal clinical study, Hernia, 27, 387, 10.1007/s10029-022-02616-8 · DOI · Paper page
- Van Rooijen, 2022, Slowly resorbable biosynthetic mesh: 2-year results in VHWG grade 3 hernia repair, Hernia, 26, 131, 10.1007/s10029-021-02453-1 · DOI
- Rosen, 2017, Multicenter, prospective, longitudinal study of the recurrence, surgical site infection, and quality of life after contaminated ventral hernia repair using biosynthetic absorbable mesh: the COBRA study, Ann Surg, 265, 205, 10.1097/SLA.0000000000001601 · DOI · Paper page
- Claessen, 2021, Outcomes of mid-term and long-term degradable biosynthetic meshes in single-stage open complex abdominal wall reconstruction, Hernia, 25, 1647, 10.1007/s10029-021-02415-7 · DOI
- Othman, 2022, Comparative effectiveness analysis of resorbable synthetic onlay and biologic intraperitoneal mesh for abdominal wall reconstruction: a 2-year match-paired analysis, Plastic & Reconstructive Surgery, 149, 1204, 10.1097/PRS.0000000000009021 · DOI · Paper page
- Tran, 2024, The use of poly-4- hydroxybutyrate (P4HB, PHASIXTM) mesh in ventral hernia repair: a systematic review and metaanalysis, Hernia, 28, 989, 10.1007/s10029-024-02996-z · DOI
- 10.1016/j.surg.2010.01.008 · DOI
- Bueno-Lledó, 2024, Long-term results with biosynthetic absorbable P4HB mesh in ventral abdominal wall repair: a multicentre analysis, Hernia, 28, 1103, 10.1007/s10029-024-02981-6 · DOI
- Burger, 2004, Long-term follow-up of a randomized controlled trial of suture versus mesh repair of incisional hernia, Ann Surg, 240, 578, 10.1097/01.sla.0000141193.08524.e7 · DOI · Paper page
- de Vries, 2020, Long-term outcomes after contaminated complex abdominal wall reconstruction, Hernia, 24, 459, 10.1007/s10029-020-02124-7 · DOI
- Ahmed, 2024, Ventral hernia repair using bioresorbable poly-4-hydroxybutyrate mesh in clean and contaminated surgical fields: a systematic review and meta-analysis, Hernia, 28, 575, 10.1007/s10029-023-02951-4 · DOI
- Morales-Conde, 2022, Ventral hernia repair in high-risk patients and contaminated fields using a single mesh: proportional meta-analysis, Hernia, 26, 1459, 10.1007/s10029-022-02668-w · DOI
- Ramos, 2021, Incidence and risk factors for long-term mesh explantation due to infection in more than 100,000 hernia operation patients, J Am Coll Surg, 232, 872, 10.1016/j.jamcollsurg.2020.12.064 · DOI
- Liang, 2014, Abdominal reoperation and mesh explantation following open ventral hernia repair with mesh, Am J Surg, 208, 670, 10.1016/j.amjsurg.2013.10.024 · DOI
- Clavien-Dindo classification of surgical complications. Definitions 2020. doi:10.32388/0hbamw · DOI
Cited by
van den Berg, R., Wieser, M., López‐Cano, M., Bueno‐Lledó, J., Köckerling, F., Chatzimavroudis, G., Gonella‐Pacchiotti, C., Stabilini, C., Ortega‐Deballon, P., Romain, B., et al. (2026) · World Journal of Surgery · doi:10.1002/wjs.70331 · Cited by 1
Self-citation
Metadata
- Authors
- van den Berg, R., Wieser, M., Jeekel, J., Stabilini, C., Bueno-Lledó, J., Köckerling, F., Chatzimavroudis, G., Jørgensen, L. N., & Romain, B.
- Affiliations
- Department of Surgery, Erasmus University Medical Centre, Rotterdam, the Netherlands
- Department of Digestive Surgery, University of Strasbourg, Hautepierre, Strasbourg, France
- Department of Neuroscience, Erasmus University Medical Centre, Rotterdam, the Netherlands
- Department of Surgery, Policlinico San Martino IRCCS and Department of Surgical Sciences, University of Genoa, Genova, Italy
- Unit of Abdominal Wall Surgery, Department of Digestive Surgery, Hospital Universitari I Poltecnic La Fe, Fernando Abril Martorell, Valencia, Spain
- Hernia Center, Vivantes Humboldt-Hospital, Academic Teaching Hospital of Charité University Medicine, Berlin, Germany
- Complex Hernia and Abdominal Wall Reconstruction Center, European Interbalkan Medical Center, Thessaloniki, Greece
- Digestive Disease Center Bispebjerg Hospital, University of Copenhagen, Copenhagen, Denmark
- Venue
- BMJ Open
- Publisher
- BMJ
- Published
- 2025-11
- Volume
- 15
- Issue
- 11
- Pages
- e098099
- ISSN
- 2044-6055
- Cited by
- 1
- References
- 2
- Language
- en
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Short‐ and Long‐Term Complications After Slowly Resorbable Biosynthetic P4HB Mesh (Phasix) Implantation in European Centres: A Protocol Paper for a Multiregistry Study. https://app.cochat.ai/papers/10.1136/bmjopen-2024-098099
- The paper
- van den Berg, R., Wieser, M., Jeekel, J., Stabilini, C., Bueno-Lledó, J., Köckerling, F., Chatzimavroudis, G., Jørgensen, L. N., & Romain, B. (2025). Short‐ and Long‐Term Complications After Slowly Resorbable Biosynthetic P4HB Mesh (Phasix) Implantation in European Centres: A Protocol Paper for a Multiregistry Study. BMJ Open. https://doi.org/10.1136/bmjopen-2024-098099
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.