Classification of aerosol-generating procedures: a rapid systematic review
Open accessThe DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
In the context of covid-19, aerosol generating procedures have been highlighted as requiring a higher grade of personal protective equipment. We investigated how official guidance documents and academic publications have classified procedures in terms of whether or not they are aerosol-generating. We performed a rapid systematic review using preferred reporting items for systematic reviews and meta-analyses standards. Guidelines, policy documents and academic papers published in english or french offering guidance on aerosol-generating procedures were eligible. We systematically searched two medical databases (medline, cochrane central) and one public search engine (google) in march and april 2020. Data on how each procedure was classified by each source were extracted. We determined the level of agreement across different guidelines for each procedure group, in terms of its classification as aerosol generating, possibly aerosol-generating, or nonaerosol-generating. 128 documents met our inclusion criteria; they contained 1248 mentions of procedures that we categorised into 39 procedure groups. Procedures classified as aerosol-generating or possibly aerosol-generating by ≥90% of documents included autopsy, surgery/postmortem procedures with high-speed devices, intubation and extubation procedures, bronchoscopy, sputum induction, manual ventilation, airway suctioning, cardiopulmonary resuscitation, tracheostomy and tracheostomy procedures, non-invasive ventilation, high-flow oxygen therapy, breaking closed ventilation systems, nebulised or aerosol therapy, and high frequency oscillatory ventilation. Disagreements existed between sources on some procedure groups, including oral and dental procedures, upper gastrointestinal endoscopy, thoracic surgery and procedures, and nasopharyngeal and oropharyngeal swabbing. There is sufficient evidence of agreement across different international guidelines to classify certain procedure groups as aerosol generating. However, some clinically relevant procedures received surprisingly little mention in our source documents. To reduce dissent on the remainder, we recommend that (a) clinicians define procedures more clearly and specifically, breaking them down into their constituent components where possible; (b) researchers undertake further studies of aerosolisation during these procedures; and (c) guideline-making and policy-making bodies address a wider range of procedures.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Preferred Reporting Items for Systematic Reviews and Meta-Analyses: the PRISMA statement
Moher, D., Liberati, A., Tetzlaff, J., Altman, D. G., & for the PRISMA Group (2009) · BMJ · doi:10.1136/bmj.b2535 · Cited by 83,823
Preferred Reporting Items for Systematic Reviews and Meta-Analyses: The PRISMA Statement
Moher, D., Liberati, A., Tetzlaff, J., Altman, D. G., & The PRISMA Group (2009) · PLoS Medicine · doi:10.1371/journal.pmed.1000097 · Cited by 64,042
Preferred reporting items for systematic reviews and meta-analyses: the PRISMA Statement.
(2009) · PubMed Central · Cited by 44,859
Wang, G., Ma, R., Qiao, G., Wada, K., Aizawa, Y., & Satoh, T. (2015) · Integrative Medicine International · doi:10.1159/000368408 · Cited by 18,657
Aerosol and surface stability of SARS-CoV-2 as compared with SARS-CoV-1
van Doremalen, N., Bushmaker, T., Morris, D. H., Holbrook, M. G., Gamble, A., Williamson, B. N., Tamin, A., Harcourt, J. L., Thornburg, N. J., Gerber, S. I., et al. (2020) · New England Journal of Medicine · doi:10.1056/nejmc2004973 · Cited by 9,951
Aerodynamic Analysis of SARS-CoV-2 in Two Wuhan Hospitals
Liu, Y., Ning, Z., Chen, Y., Guo, M., Liu, Y., Gali, N. K., Sun, L., Duan, Y., Cai, J., Westerdahl, D., et al. (2020) · Nature · doi:10.1038/s41586-020-2271-3 · Cited by 1,872
Bourouiba, L. (2020) · JAMA · doi:10.1001/jama.2020.4756 · Cited by 1,066
Li, Y., Leung, G. M., Tang, J. W., Yang, X., Chao, C. Y. H., Lin, J. Z., Lu, J. W., Nielsen, P. V., Niu, J., Qian, H., et al. (2007) · Indoor Air · doi:10.1111/j.1600-0668.2006.00445.x · Cited by 1,055
The size and the duration of air-carriage of respiratory droplets and droplet-nuclei
Duguid, J. P. (1946) · Epidemiology and Infection · doi:10.1017/s0022172400019288 · Cited by 850
The size distribution of droplets in the exhaled breath of healthy human subjects
PAPINENI, R. S., & ROSENTHAL, F. S. (1997) · Journal of Aerosol Medicine · doi:10.1089/jam.1997.10.105 · Cited by 690
Cited by
Berlin, D. A., Gulick, R. M., & Martinez, F. J. (2020) · New England Journal of Medicine · doi:10.1056/nejmcp2009575 · Cited by 1,439
Metadata
- Authors
- Jackson, T., Deibert, D., Wyatt, G., Durand-Moreau, Q., Adisesh, A., Khunti, K., Khunti, S., Smith, S., Chan, X. H. S., Ross, L., Roberts, N., Toomey, E., Greenhalgh, T., Arora, I., Black, S. M., Drake, J., Syam, N., Temple, R., & Straube, S.
- Venue
- BMJ Open Respiratory Research
- Publisher
- BMJ
- Published
- 2020-10
- Volume
- 7
- Issue
- 1
- Pages
- e000730
- ISSN
- 2052-4439 (ISSN-L)
- OpenAlex
- W3092334594
- Cited by
- 187
- References
- 26
- FWCI
- 7.91
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.