The DOI matches its Crossref record.
Gastric emptying in normal subjects--a reproducible technique using a single scintillation camera and computer system.
Open accessAbstract
The gastric emptying of a mixed solid and liquid meal was assessed in 24 normal subjects using a single camera/computer system which allowed continuous monitoring of both solids and liquids. It was shown that variation in tissue attenuation caused by the changing depth of radionuclide within the stomach accounted for large errors in the measurement of gastric emptying (alteration in 50% emptying time of up to 65%). A technique for the correction of attenuation is described which used factors derived from a lateral image of the stomach. In all subjects, solid emptying was slower than liquid emptying and was characterised by a delay (lag period) which was followed by linear emptying. Liquid emptying usually followed a single exponential pattern. The effect of physiological changes induced by increasing the calorie content of the liquid component of the meal was assessed by giving either water, 10% dextrose or 25% dextrose. Liquid emptying was slowed and the lag period of solid was prolonged as the calorie content increased. Reproducibility was assessed in 19 subjects. For the three groups studied (water, 10% dextrose, 25% dextrose) the day-to-day variation in gastric emptying was not significant for any measured parameter, while statistically significant differences were present in solid and liquid emptying between subjects and groups.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A standardised static in vitro digestion method suitable for food – an international consensus
Minekus, M., Alminger, M., Alvito, P., Ballance, S., Bohn, T., Bourlieu, C., Carrière, F., Boutrou, R., Corredig, M., Dupont, D., et al. (2014) · Food Funct. · doi:10.1039/c3fo60702j · Cited by 5,824
Steinert, R. E., Feinle-Bisset, C., Asarian, L., Horowitz, M., Beglinger, C., & Geary, N. (2017) · Physiological Reviews · doi:10.1152/physrev.00031.2014 · Cited by 578
Self-citationRelationship between oral glucose tolerance and gastric emptying in normal healthy subjects
Horowitz, M., Edelbroek, M. A. L., Wishart, J. M., & Straathof, J. W. (1993) · Diabetologia · doi:10.1007/bf00400362 · Cited by 469
Self-citationGentilcore, D., Chaikomin, R., Jones, K. L., Russo, A., Feinle-Bisset, C., Wishart, J. M., Rayner, C. K., & Horowitz, M. (2006) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2005-2644 · Cited by 351
Self-citationMüller, M., Canfora, E., & Blaak, E. (2018) · Nutrients · doi:10.3390/nu10030275 · Cited by 329
Metadata
- Authors
- Collins, P. J., Horowitz, M., Cook, D. J., Harding, P. E., & Shearman, D. J.
- Venue
- Gut
- Publisher
- BMJ
- Published
- 1983-12
- Volume
- 24
- Issue
- 12
- Pages
- 1117-1125
- ISSN
- 0017-5749 (ISSN-L)
- 1468-3288
- OpenAlex
- W2080881783
- Cited by
- 412
- References
- 0
- FWCI
- 16.98
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Gastric emptying in normal subjects--a reproducible technique using a single scintillation camera and computer system. https://app.cochat.ai/papers/10.1136/gut.24.12.1117
- The paper
- Collins, P. J., Horowitz, M., Cook, D. J., Harding, P. E., & Shearman, D. J. (1983). Gastric emptying in normal subjects--a reproducible technique using a single scintillation camera and computer system. Gut. https://doi.org/10.1136/gut.24.12.1117
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.