CoChat

Interpretation of the breath hydrogen profile obtained after ingesting a solid meal containing unabsorbable carbohydrate.

Open access
Read, N W, Al-Janabi, M N, Bates, T E, Holgate, A M, Cann, P A, Kinsman, R I, McFarlane, A, Brown, C · 1985 · Gut
Cited by 141

The DOI matches its Crossref record.

Abstract

The extent to which monitoring breath hydrogen excretion provides information concerning the entry of the residues of a solid test meal into the colon was investigated in 89 normal subjects, and 11 patients with the irritable bowel syndrome. The profile of breath hydrogen concentration showed an early peak, that occurred soon after ingesting the test meal in 89% subjects. This was followed by a later more prolonged rise in breath hydrogen concentration. The early peak occurred well before a radioactive marker, incorporated in the test meal, reached the caecum and the data suggest it was predominantly caused by the emptying of the remnants of the previous meal from the ileum into the colon. This hypothesis was supported by direct measurements of the rate of delivery of ileostomy effluent in 12 subjects with terminal ileostomies. Fermentation of carbohydrate in the mouth may, however, contribute to the initial peak, but this contribution may be avoided by collecting gas samples from the nares. The secondary rise in breath hydrogen excretion was closely correlated with the arrival of the radioactive marker in the caecum (r = 0.91), p less than 0.001), though the time, at which the secondary peak of breath hydrogen excretion occurred was poorly correlated with the time that all the radioactive test meal had entered the colon. When lactulose was infused directly into the colon, as little as 0.5 g produced a discernible hydrogen response, which occurred within two minutes of the infusion. Increasing the rate of colonic infusion of a 50 ml solution of 10% lactulose from 0.02 to 0.15 g/min in five subjects significantly increased the breath hydrogen concentration. At infusion rates below 0.075 g lactulose/minute, the peak breath hydrogen response preceded the end ot the infusion, while at higher rates of infusion, the peak hydrogen response occurred after the end of the infusion. Although these results confirmed that monitoring breath hydrogen concentration usefully signalled the time taken for a meal containing unabsorbed carbohydrate to reach the colon, it did not reliably indicate the time when all of the meal had entered the colon. Finally, the use of the maximum increase in breath hydrogen concentration as an index of the degree of carbohydrate malabsorption assumes uniform rates of entry into the colon.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/gut.26.8.834

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Read, N. W., Al-Janabi, M. N., Bates, T. E., Holgate, A. M., Cann, P. A., Kinsman, R. I., McFarlane, A., & Brown, C.
Venue
Gut
Publisher
BMJ
Published
1985-08
Volume
26
Issue
8
Pages
834-842
ISSN
  • 0017-5749 (ISSN-L)
  • 1468-3288
OpenAlex
W1992799308
Cited by
141
References
0
FWCI
10.49
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.