Assessment of the percutaneous endoscopic gastrostomy feeding tube as part of an integrated approach to enteral feeding.
Open accessThe DOI matches its Crossref record.
Abstract
The insertion of percutaneous endoscopic gastrostomy has been well documented. The possible benefits for patient nutrition and nursing practice have, however, not been assessed. We report a study of enteral feeding by percutaneous endoscopic gastrostomy in 30 patients, the majority with a persistent vegetative state. All patients had previously been fed through a nasogastric tube using manual administration and a dietitian assessed protein calorie intake. Based upon body mass index (weight/height2), midarm circumference and triceps skinfold thickness, 20 (67%) were malnourished, with 10 patients having a body mass index less than 17 (severe malnutrition); attributed to high rates of both tube displacement and feed regurgitation. Patients were observed over six to 12 months after percutaneous endoscopic gastrostomy insertion combined with overnight continuous pump feeding. All patients attained a body mass index greater than 17, and 17 (56%) of the total number achieved the normal range with no change in protein-calorie intake (pre: 2110 kcal, post: 1880 kcal). Complications of percutaneous endoscopic gastrostomy in the study group included peritonitis (one), tube site infection (two) and displacement (two); all without serious sequelae. As part of an integrated approach percutaneous endoscopic gastrostomy proved a safe and efficient method of enteral feeding and justifies wider consideration in the United Kingdom.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
(2005) · Clinical Nutrition · doi:10.1016/j.clnu.2005.06.013 · Cited by 594
Norton, B., Homer-Ward, M., Donnelly, M. T., Long, R. G., & Holmes, G. K. T. (1996) · BMJ · doi:10.1136/bmj.312.7022.13 · Cited by 448
Percutaneous endoscopic gastrostomy and enteral nutrition in amyotrophic lateral sclerosis
Mazzini, L., Corrà, T., Zaccala, M., Mora, G., Del Piano, M., & Galante, M. (1995) · Journal of Neurology · doi:10.1007/bf00866922 · Cited by 339
Interventions for dysphagia and nutritional support in acute and subacute stroke
Geeganage, C., Beavan, J., Ellender, S., & Bath, P. M. (2012) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd000323.pub2 · Cited by 282
Loser, C., Wolters, S., & Folsch, U. R. (1998) · Digestive Diseases and Sciences · doi:10.1023/a:1026615106348 · Cited by 157
Metadata
- Authors
- Wicks, C., Gimson, A., Vlavianos, P., Lombard, M., Panos, M., Macmathuna, P., Tudor, M., Andrews, K., & Westaby, D.
- Venue
- Gut
- Publisher
- BMJ
- Published
- 1992-05
- Volume
- 33
- Issue
- 5
- Pages
- 613-616
- ISSN
- 0017-5749 (ISSN-L)
- 1468-3288
- OpenAlex
- W2032281586
- Cited by
- 83
- References
- 0
- FWCI
- 6.03
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Assessment of the percutaneous endoscopic gastrostomy feeding tube as part of an integrated approach to enteral feeding. https://app.cochat.ai/papers/10.1136/gut.33.5.613
- The paper
- Wicks, C., Gimson, A., Vlavianos, P., Lombard, M., Panos, M., Macmathuna, P., Tudor, M., Andrews, K., & Westaby, D. (1992). Assessment of the percutaneous endoscopic gastrostomy feeding tube as part of an integrated approach to enteral feeding. Gut. https://doi.org/10.1136/gut.33.5.613
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.